35 Ill. Adm. Code 226.165
Inspection
Section 226.165 Inspection
a) An
owner or operator of a lead emission unit subject to this Part must inspect
control devices for the control of lead particulate at least once per month. The
inspections of control devices must include all structures that comprise the
infrastructure of the affected control device and other structures that are
necessary for the affected control device to function in its intended
capacity.
b) An
owner or operator of a lead emission unit subject to this Part must inspect all
total enclosures for proper operation and physical integrity at least once per
month.
c) An
owner or operator of a lead emission unit subject to this Part must maintain
and repair any control device and total enclosure, including all structures
that comprise the infrastructure of the affected control device and total
enclosure, as necessary to ensure proper and compliant operation.