35 Ill. Adm. Code 2290.229.102
Definitions
Section 229
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE B: GENERAL PROVISIONS
CHAPTER I: POLLUTION CONTROL BOARD
SUBCHAPTER c: EMISSION STANDARDS AND LIMITATIONS FOR STATIONARY SOURCES
PART 229 HOSPITAL/MEDICAL/INFECTIOUS WASTE INCINERATORS
SECTION 229.102 DEFINITIONS
Section 229.102 Definitions
The definitions contained in
this Section apply only to the provisions of this Part. Unless otherwise
defined herein and unless a different meaning of a term is clear from its
context, the definitions of terms used in this Part shall have the meanings specified
for those terms in 415 ILCS 5/39.5, 35 Ill. Adm. Code 201.102 or 35 Ill. Adm.
Code 211.
"Bag leak
detection system" means an instrument that is capable of monitoring PM loadings
in the exhaust of a fabric filter in order to detect bag failures. A bag leak detection
system includes, but is not limited to, an instrument that operates on triboelectric,
lightscattering, light-transmittance, or other effects to monitor relative PM loadings.
"Batch
HMIWI" means an HMIWI that is designed in such a way that neither waste
charging nor ash removal can occur during combustion.
"Biologicals"
means preparations made from living organisms and their products, including
vaccines, cultures, etc., intended for use in diagnosing, immunizing, or
treating humans or animals or in research pertaining thereto.
"Body
fluids" means liquid emanating or derived from humans and limited to:
blood; dialysate; amniotic, cerebrospinal, synovial, pleural, peritoneal and
pericardial fluids; semen and vaginal secretions.
"Bypass
stack" means an alternative stack used for discharging combustion gases to
the atmosphere primarily to avoid severe damage to an air pollution control
device or other equipment.
"Charge"
means the act of placing waste into an HMIWI for incineration.
"Chemotherapeutic
waste" means waste material resulting from the production or use of
antineoplastic agents used for the purpose of stopping or reversing the growth
of malignant cells.
"Co-fired
combustor" means a unit combusting hospital waste or medical/infectious
waste with other fuels or wastes (e.g., coal, municipal solid waste) and
subject to an enforceable requirement limiting the unit to combusting a fuel
feed stream, of which 10 percent or less of the weight is comprised, in
aggregate, of hospital waste and medical/infectious waste as measured on a
calendar quarter basis. For purposes of this definition, pathological waste,
chemotherapeutic waste, and low-level radioactive waste are considered
"other" wastes when calculating the percentage of hospital waste and
medical/infectious waste combusted.
"Commercial
HMIWI" means an HMIWI that offers incineration services for hospital/medical/
infectious waste generated offsite by firms unrelated to the firm that owns the
HMIWI.
"Continuous
emission monitoring system" or "CEMS" means a monitoring system
for continuously measuring and recording the emissions of a pollutant from an
affected facility.
"Continuous
HMIWI" means an HMIWI that is designed to allow waste charging and ash
removal during combustion.
"Dioxins/furans"
means the total emissions of any tetra- through octa-chlorinated
dibenzo-para-dioxins and dibenzofurans, as measured by EPA Reference Method 23,
incorporated by reference in Section 229.104(d) of this Subpart.
"Dry
scrubber" means an add-on air pollution control system that injects dry
alkaline sorbent (dry injection) or sprays an alkaline sorbent (spray dryer) to
react with and neutralize acid gases in an HMIWI exhaust stream, forming a dry
powder material.
"Fabric
filter" means an add-on air pollution control system that removes PM and
nonvaporous metals emissions by passing flue gas through filter bags.
"Facilities
manager" means the individual in charge of purchasing, maintaining, and
operating an HMIWI, or the owner's or operator's representative responsible for
the management of an HMIWI. Alternative titles may include director of
facilities or vice president of support services.
"High air
phase" means the stage of the batch operating cycle when the primary
chamber reaches and maintains maximum operating temperatures.
"Hospital"
means any facility that has an organized medical staff, maintaining at least 6
inpatient beds and where the primary function of the facility is to provide
diagnostic and therapeutic patient services and continuous nursing care
primarily to human inpatients who are not related and who stay on average in
excess of 24 hours per admission. This definition does not include facilities
maintained for the sole purpose of providing nursing or convalescent care to
human patients who generally are not acutely ill but who require continuing
medical supervision.
"Hospital/medical/infectious
waste incinerator" or "HMIWI" means any device that combusts any
amount of hospital waste or medical/infectious waste.
"Hospital
waste" means discards generated at a hospital, except unused items
returned to the manufacturer. The definition of hospital waste does not include
human corpses, remains, or anatomical parts that are intended for interment or
cremation.
"HMIWI
operator" means any person who operates, controls, or supervises the
day-to-day operation of an HMIWI.
"Infectious
agent" means any organism that is capable of being communicated by
invasion and multiplication in body tissues and is also capable of causing
disease or adverse health impacts in humans.
"Intermittent
HMIWI" means an HMIWI that is designed to allow waste charging, but not
ash removal, during combustion.
"Large
HMIWI" means:
An HMIWI whose
maximum design waste burning capacity is more than 500 lbs per hour; or
A continuous
or intermittent HMIWI whose maximum charge rate is more than 500 lbs per hour;
or
A batch HMIWI
whose maximum charge rate is more than 4,000 lbs per day.
"Low-level
radioactive waste" means waste that contains radioactive nuclides emitting
primarily beta or gamma radiation, or both, in concentrations or quantities that
exceed applicable Federal or State standards for unrestricted release.
Low-level radioactive waste is not high-level radioactive waste, spent nuclear
fuel, or by-product material as defined by the Atomic Energy Act of 1954 (42 USC
2014(e)(2)).
"Malfunction"
means any sudden, infrequent, and not reasonably preventable failure of air
pollution control equipment, process equipment, or of a process to operate in a
normal or usual manner. Failures that are caused, in part, by poor maintenance
or careless operation are not malfunctions.
"Maximum charge rate" means:
For continuous and intermittent
HMIWI, 110 percent of the lowest 3-hour average charge rate measured during the
most recent performance test demonstrating compliance with all applicable
emission limits specified in Subpart E of this Part.
For batch HMIWI, 110 percent of
the lowest daily charge rate measured during the most recent performance test
demonstrating compliance with all applicable emission limits specified in
Subpart E of this Part.
"Maximum
design waste burning capacity" means:
For
intermittent and continuous HMIWI:
Where:
C
=
HMIWI capacity, lb/hr
P
v
=
primary chamber volume, ft
3
15,000
=
primary chamber heat release
rate factor, Btu/ft
3
/hr
8,500
=
standard waste heating value,
Btu/lb;
For batch HMIWI:
Where:
C
=
HMIWI capacity, lb/hr
P
v
=
primary chamber volume, ft
3
4.5
=
waste density factor, lb/ft
3
8
=
typical hours of operation of
a batch HMIWI, hours.
"Maximum fabric filter inlet
temperature" means 110 percent of the lowest 3-hour average temperature at
the inlet to the fabric filter (taken, at a minimum, once every minute)
measured during the most recent performance test demonstrating compliance with
the applicable dioxin/furan emission limit specified in Subpart E of this Part.
"Maximum flue gas
temperature" means 110 percent of the lowest 3-hour average temperature at
the outlet from the wet scrubber (taken, at a minimum, once every minute)
measured during the most recent performance test demonstrating compliance with
the applicable Hg emission limit specified in Subpart E of this Part.
"Medical/infectious
waste" means any waste generated in the diagnosis, treatment, or
immunization of human beings or animals, in research pertaining thereto, or in
the production or testing of biologicals. The definition of medical/infectious
waste does not include hazardous waste identified or listed under the
regulations in 40 CFR 261; household waste, as defined in 40 CFR 261.4(b)(1);
and domestic sewage materials identified in 40 CFR 261.4(a)(1). For the
purposes of this Part, medical/infectious waste includes:
Cultures and stocks of infectious agents and associated biologicals,
including: vaccines and cultures intended for use in diagnosing, immunizing,
or treating humans or animals; cultures from medical and pathological
laboratories; cultures and stocks of infectious agents from research and
industrial laboratories; wastes from the production of biologicals; and
discarded live and attenuated vaccines;
Human pathological waste, including tissues, organs, and body parts and
body fluids that are removed during surgery or autopsy, or other medical
procedures, and specimens of body fluids and their containers;
Human blood, any products derived from human blood, or anything that has
been in contact with human blood in any form;
Intravenous bags and associated tubing;
Sharps that have been used in animal or human patient care or treatment
or in medical, research, or industrial laboratories, including hypodermic
needles, syringes (with or without the attached needle), pasteur pipettes,
scalpel blades, blood vials, and needles with attached tubing;
Culture dishes, regardless of the presence of infectious agents, and
culture dishes and devices used to transfer, inoculate, and mix cultures;
Any type of broken or unbroken glassware that has been in contact with
infectious agents;
Animal waste, including contaminated animal carcasses, body parts,
bedding of animals that were known to have been exposed to infectious agents
during research (including research in veterinary hospitals), production of biologicals
or testing of pharmaceuticals;
Isolation wastes, including biological waste and discarded materials
contaminated with blood, excretions, exudates, or secretions from humans who
are isolated to protect others from highly communicable diseases, or isolated
animals known to be infected with highly communicable diseases; and
Unused sharps, including the following unused, discarded sharps:
hypodermic needles, suture needles, syringes, and scalpel blades.
"Medium HMIWI" means:
An HMIWI whose maximum design
waste burning capacity is more than 200 lbs per hour but less than or equal to
500 lbs per hour; or
A continuous or intermittent HMIWI
whose maximum charge rate, as set by permit, is more than 200 lbs per hour but
less than or equal to 500 lbs per hour; or
A batch HMIWI whose maximum charge
rate, as set by permit, is more than 1,600 lbs per day but less than or equal
to 4,000 lbs per day.
"Minimum dioxin/furan sorbent
flow rate" means 90 percent of the highest 3-hour average dioxin/furan
sorbent flow rate (taken, at a minimum, once every hour) measured during the
most recent performance test demonstrating compliance with the applicable
dioxin/furan emission limit specified in Subpart E of this Part.
"Minimum Hg sorbent flow
rate" means 90 percent of the highest 3-hour average Hg sorbent flow rate
(taken, at a minimum, once every hour) measured during the most recent
performance test demonstrating compliance with the applicable Hg emission limit
specified in Subpart E of this Part.
"Minimum HCl sorbent flow
rate" means 90 percent of the highest 3-hour average HCl sorbent flow rate
(taken, at a minimum, once every hour) measured during the most recent
performance test demonstrating compliance with the applicable HCl emission
limit specified in Subpart E of this Part.
"Minimum horsepower" or
"minimum amperage" means 90 percent of the highest 3-hour average
horsepower or amperage to the wet scrubber (taken, at a minimum, once every
minute) measured during the most recent performance test demonstrating
compliance with the applicable emission limits specified in Subpart E of this
Part.
"Minimum pressure drop across
the wet scrubber" means 90 percent of the highest 3-hour average pressure
drop across the wet scrubber PM control device (taken, at a minimum, once every
minute) measured during the most recent performance test demonstrating
compliance with the applicable PM emission limit specified in this Subpart E of
this Part.
"Minimum reagent flow
rate" means 90 percent of the highest 3-hour average reagent flow rate at
the inlet to the selective noncatalytic reduction technology (taken, at a
minimum, once every minute) measured during the most recent performance test
demonstrating compliance with the applicable NO
x
emissions limit
specified in Subpart E of this Part.
"Minimum scrubber liquor flow
rate" means 90 percent of the highest 3-hour average liquor flow rate at
the inlet to the wet scrubber (taken, at a minimum, once every minute) measured
during the most recent performance test demonstrating compliance with the applicable
emission limits specified in Subpart E of this Part.
"Minimum scrubber liquor
pH" means 90 percent of the highest 3-hour average liquor pH at the inlet
to the wet scrubber (taken, at a minimum, once every minute) measured during
the most recent performance test demonstrating compliance with the applicable
HCl emission limit specified in Subpart E of this Part.
"Minimum secondary chamber
temperature" means 90 percent of the highest 3-hour average secondary
chamber temperature (taken, at a minimum, once every minute) measured during
the most recent performance test demonstrating compliance with the PM, CO,
dioxin/furan, and applicable NO
x
emissions limits specified in
Subpart E of this Part.
"Operating day" means a
24-hour period between 12:00 midnight and the following midnight during which
any amount of hospital waste or medical/infectious waste is combusted at any
time in an HMIWI.
"Operation" means any
period during which waste is combusted in an HMIWI, excluding periods of
startup or shutdown.
"Pathological waste"
means waste material consisting of only human or animal remains, anatomical
parts, tissue, and the bags or containers used to collect and transport the
waste material and associated animal bedding, if applicable.
"Primary chamber" means
the chamber in an HMIWI that receives waste material, in which the waste is
ignited, and from which ash is removed.
"Rural HMIWI" means any
HMIWI identified in Section 229.110(a) of this Part, that is located more than
50 miles from the boundary of the nearest Standard Metropolitan Statistical
Area, as defined in OMB Bulletin No. 93-17, incorporated by reference at
Section 229.104(b) of this Part, meets the criteria specified in the definition
of "small HMIWI" and burns less than 2,000 lbs per week of hospital
waste and medical/infectious waste (except the 2,000 lbs per week limitation
does not apply during performance testing).
"Secondary chamber"
means that component of an HMIWI that receives combustion gases from the
primary chamber and in which the combustion process is completed.
"Shutdown" means the
period of time after all waste has been combusted in the primary chamber.
"Small HMIWI" means:
An HMIWI whose
maximum design waste burning capacity is less than or equal to 200 lbs per
hour; or
A continuous or intermittent HMIWI whose maximum charge rate,
as set by permit, is less than or equal to 200 lbs per hour; or
A batch HMIWI whose maximum charge rate, as set by permit, is
less than or equal to 1,600 lbs per day.
"Startup"
means the period of time between the activation of an HMIWI and the first
charge of waste to the unit. For batch HMIWI, startup means the period of time
between activation of an HMIWI and ignition of the waste.
"Wet
scrubber" means an add-on air pollution control device that utilizes
either an alkaline or some other type of scrubbing liquor to collect pollutants
and/or neutralize acid gases.