35 Ill. Adm. Code 2290.229.142
Initial Performance Testing and Establishment of Operating Parameters for All HMIWIs
Section 229
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE B: GENERAL PROVISIONS
CHAPTER I: POLLUTION CONTROL BOARD
SUBCHAPTER c: EMISSION STANDARDS AND LIMITATIONS FOR STATIONARY SOURCES
PART 229 HOSPITAL/MEDICAL/INFECTIOUS WASTE INCINERATORS
SECTION 229.142 INITIAL PERFORMANCE TESTING AND ESTABLISHMENT OF OPERATING PARAMETERS FOR ALL HMIWIS
Section 229.142 Initial
Performance Testing and Establishment of Operating Parameters
for All HMIWIs
a) Before January 1,
2014, each
owner or operator of an HMIWI as defined
in Section 229.110(a)(1) of this Part, subject to the emissions limits under
Section
229.125(a) or Section 229.126(a) of this Part,
shall
comply with the following requirements:
1) Except as provided in Section 229.115(a)(2)(B)(v) of this
Part, conduct an initial performance test on their HMIWI by September 15, 2000.
2) Except as provided in subsection (a)(3) of this Section, in
the initial performance test, test for all pollutants limited pursuant to
Subpart E of this Part.
3) During the initial performance test, rural HMIWIs are not
required to test for HCl, Pb or Cd.
4) If an HMIWI is equipped with a dry scrubber followed by a
fabric filter, a wet scrubber, or a dry scrubber followed by a fabric filter
and wet scrubber,
or a selective noncatalytic
reduction system,
establish the appropriate maximum and minimum
operating parameter values indicated in Appendix B of this Part for the
relevant control system during the initial performance test, provided that the performance
test demonstrates compliance with the emission limits specified in Section
229.125 of this Part.
5) If air pollution control equipment other than a dry scrubber
followed by a fabric filter, a wet scrubber, a dry scrubber followed by a
fabric filter and a wet scrubber,
or a selective
noncatalytic reduction system
is used to comply with the emission limits
under Section 229.125 of this Part, the initial performance test may not be
conducted until site-specific operating parameters that will be monitored to
demonstrate compliance with this Part have been established by the Agency in a
construction permit and approved by USEPA.
6) For rural HMIWI, establish the maximum charge rate and minimum
secondary chamber temperature as site-specific parameters during the initial
performance test, provided that the performance test demonstrates that the
HMIWI is in compliance with the emission limits specified in Section 229.126 of
this Part.
b) On
and after January 1, 2014, each
owner or operator of
an HMIWI, as defined in Section 229.110(a)(1) or (a)(2) of this Part, and
subject to the emissions limits under
Section 229.125(c) as applicable,
or Section 229.126(c)
of this Part, shall comply with
the following requirements:
1) Except
as provided in Section 229.115(b)(2)(B)(v) of this Part, conduct an initial
performance test on its HMIWI by January 1, 2014.
2) Except
as provided for in subsection (b)(6), in the initial performance test, test for
all pollutants to demonstrate compliance with Section 229.125(c) or Section
229.126(c) emissions limits, as applicable, pursuant to Subpart E of this Part.
3
) If an HMIWI is equipped with a dry scrubber
followed by a fabric filter, a wet scrubber, a dry scrubber followed by a
fabric filter and wet scrubber, or a selective noncatalytic reduction system,
establish the appropriate maximum and minimum operating parameter values
indicated in Appendix B of this Part for the relevant control system during the
initial performance test, provided that the performance test demonstrates
compliance with the emission limits specified in Section 229.125 or 229.126 of
this Part
.
4) If an air pollution control device other than a
dry scrubber followed by a fabric filter, a wet scrubber, a dry scrubber
followed by a fabric filter and a wet scrubber, or a selective noncatalytic
reduction system is used to comply with the emission limits under Section
229.125 or Section 229.126 of this Part, the initial performance test may not
be conducted until site-specific operating parameters that will be monitored to
demonstrate compliance with this Part have been established by the Agency in a
construction permit and approved by USEPA.
5) For a
rural HMIWI that is not equipped with an air pollution control device,
establish the maximum charge rate and minimum secondary chamber temperature as
site-specific parameters during the initial performance test, provided that the
performance test demonstrates that the HMIWI is in compliance with the emission
limits specified in Section 229.126(c) of this Part.
6
) The owner or operator of an HMIWI may use
results of previous performance tests for initial compliance demonstration with
the applicable emissions limits, provided the following conditions are met:
A) The
previous emissions tests were conducted using procedures and test methods
listed in Section 229.140 of this Part or USEPA-accepted voluntary consensus
standards;
B) The
test results are certified as representative of current operations; and
C) The
previous emissions tests were conducted no earlier than 1996.
7) The
owner or operator of an HMIWI that cannot certify and/or whose previous
performance test results do not demonstrate compliance with one or more of the
revised emission limits must conduct another performance test for those
pollutants.
8) The
owner or operator of an HMIWI, as defined in Section 229.110(a)(1) or (a)(2) of
this Part, and subject to the emissions limits under Section 229.125(c) as
applicable, or Section 229.126(c) of this Part, as applicable, shall determine
compliance with the visible emissions limit for fugitive emissions from ash
handling in Sections 229.125(g) and 229.126(e) by conducting an initial
performance test using Method 22, at 40 CFR 60, appendix A, incorporated by
reference at Section 229.104(d) of this Part.