35 Ill. Adm. Code 229.152
Compliance Requirements for HMIWIs using CEMS
Section 229
Section 229.152 Compliance
Requirements for HMIWIs using CEMS
The owner or operator of an
HMIWI may use a CEMS to demonstrate compliance with any of the emission limits
under Section 229.125 or Section 229.126 of this Part, if provided for in its
permit.
a) Any
HMIWI that is allowed to use a CEMS to demonstrate compliance with the emission
limits of this Part shall:
1) Determine compliance with the applicable emission limits using
a 12-hour rolling average, calculated each hour as the average of the previous
12 operating hours; and
2) Operate all CEMS in accordance with the applicable procedures
under appendices B and F of 40 CFR 60, incorporated by reference at Section
229.104(e) of this Part.
b) In
the case of CEMS for which USEPA has not published performance specifications,
the option to use the CEMS takes effect on the date of publication of the
performance specifications in the Federal Register or after site-specific
operating parameters used to demonstrate compliance with this Part have been
established by the Agency in a construction permit and approved by USEPA.