35 Ill. Adm. Code 229.166
Monitoring Requirements for All HMIWIs
Section 229
Section 229.166 Monitoring
Requirements for All HMIWIs
a) Each
owner or operator of an HMIWI subject to the emissions limits under Section
229.125(c) as applicable, or Section 229.126(c) of this Part, shall comply with
requirements of this Section according to the following schedule:
1) Before
January 1, 2014, for a small, medium or large HMIWI;
2) On
and after January 1, 2014, except as provided for in Section 229.115(b)(3) or
Section 229.116(c)(4), for a small, medium or large HMIWI and a rural HMIWI
that is equipped with an air pollution control device.
b) Once the initial performance test required by Section 229.142
of this Part has been performed, and the site-specific minimum and maximum
operating parameter values have been established, the owner or operator of an
HMIWI, as applicable, shall continuously monitor those parameters.
c) The owner or operator of an HMIWI, as applicable, shall comply
with the following monitoring requirements:
1) Install, calibrate according to manufacturer's specifications,
maintain, and operate devices or establish methods for monitoring the
applicable maximum and minimum operating parameters specified in Appendix B of
this Part (unless CEMS are used as a substitute for certain parameters as
specified) so that these devices or methods measure and record values for these
operating parameters at the frequencies indicated in Appendix B of this Part at
all times;
2) Install, calibrate according to manufacturer's specifications,
maintain, and operate a device or establish a method for identifying the use of
the bypass stack, including date, time, and duration of use;
3) If control equipment other than a dry scrubber followed by a
fabric filter, a wet scrubber, a dry scrubber followed by a fabric filter and a
wet scrubber, or a selective noncatalytic reduction system is used to comply
with the applicable emissions limits under Section 229.125(c) as applicable, or
Section 229.126(c) of this Part, install, calibrate according to manufacturer's
specifications, maintain, and operate the equipment necessary to monitor the
site-specific operating parameters developed and approved pursuant to Section
229.142(a)(5) or (b)(5) of this Part; and
4) Record monitoring data at all times during HMIWI operation,
except during the periods of monitoring equipment malfunction, calibration, or
repair. At a minimum, valid monitoring data shall be recorded for 75 percent
of the operating hours per day for 90 percent of the operating days per
calendar quarter that an HMIWI is combusting hospital waste or
medical/infectious waste.
d) If an
HMIWI is equipped with an air pollution control device that includes a fabric
filter and a PM CEMS is not used to demonstrate compliance, the owner or
operator of the HMIWI may use a bag leak detection system to determine
compliance with the PM emissions limit. The owner or operator shall meet the
following requirements for each bag leak detection system installed:
1) Each
triboelectric bag leak detection system may be installed, calibrated, operated,
and maintained according to the "Fabric Filter Bag Leak Detection Guidance,"
as incorporated by reference in Section 229.104;
2) The
bag leak detection system shall be certified by the manufacturer as being
capable of detecting PM emissions at concentrations of 10 milligrams per actual
cubic meter (0.0044 grains per actual cubic foot) or less;
3) The
bag leak detection system sensor shall provide an output of relative PM loadings;
4) The
bag leak detection system shall be equipped with a device to continuously
record the output signal from the sensor;
5) The
bag leak detection system shall be equipped with an audible alarm system that
sounds automatically when an increase in relative PM emissions over a preset
level is detected. The alarm shall be located where it is easily heard by
plant operating personnel;
6) For
positive pressure fabric filter systems, a bag leak detector shall be installed
in each baghouse compartment or cell;
7) For
negative pressure or induced air fabric filters, a bag leak detector shall be
installed downstream of the fabric filter;
8) If
multiple bag leak detectors are required, the bag leak detection system's
instrumentation and alarm may be shared among detectors;
9) The
baseline output shall be established by adjusting the range and the averaging
period of the device and establishing the alarm set points and the alarm delay
time according to section 5.0 of the "Fabric Filter Bag Leak Detection
Guidance," as incorporated by reference in Section 229.104;
10) Following
initial adjustment of the system, the sensitivity or range, averaging period,
alarm set points, or alarm delay time may not be adjusted. Increasing the
sensitivity by more than 100 percent or decreasing by more than 50 percent over
a 365-day period is a violation, unless the adjustment follows a complete
fabric filter inspection that demonstrates that the fabric filter is in good
operating condition. Each adjustment shall be recorded;
11) Records
of the results of each inspection, calibration, and validation check shall be
maintained; and
12) The
fabric filter must be operated and maintained so that the bag leak detection
system alarm is not engaged for more than 5 percent of the total operating time
in a 6-month block reporting period; however, corrective action must be
initiated within 1 hour after the alarm.