35 Ill. Adm. Code 276.504
Evaporative System Integrity Test Functional Requirements and Performance Criteria
Section 276
Section 276.504 Evaporative
System Integrity Test Functional Requirements and Performance Criteria
a) Requirements
Both fuel cap leak flow testers and fuel cap pressure decay
testers used for evaporative system integrity testing shall be:
1) Easily connected to fuel caps, including those tethered to the
vehicle;
2) Compatible with at least 95 percent of all vehicles required
to receive a fuel cap test;
3) Adaptable as required to test future model year vehicles as
they enter the eligible fleet;
4) Capable of performing the following additional functions:
A) Provide reliable, continuous service;
B) Provide for the automatic selection of the proper fuel cap test
equipment (if applicable) for each vehicle tested;
C) Provide for an automatic pass/fail determination for each
vehicle tested;
5) Unaffected by atmospheric variation (i.e., barometric
pressure, humidity, temperature, etc.). Test accuracy shall be within 2
percent of stated values from 0ºF to 120ºF;
6) Pressurized using air, Nitrogen (N
2
), or an
equivalent non-toxic, non-greenhouse, inert gas;
7) Capable of controlling the supply pressure and preventing over
pressurization;
8) Tamper resistant; and
9) Designed to avoid damage to the vehicle during installation,
testing and removal.
b) Fuel cap pressure decay tester
The fuel cap pressure decay tester used for evaporative
system integrity testing shall be equipped with a pressure gauge with a minimum
range of 0 to 50 inches of water and an accuracy of 0.3 inches of water or 2
percent of point, whichever is greater.
c) Fuel cap leak flow tester
The fuel cap leak flow tester used for evaporative system
integrity testing shall be:
1) Equipped with a serviceable air filter upstream of the flow
comparison circuitry;
2) Equipped with an automatic shutoff and a low-battery indicator
if battery powered;
3) Supplied with a NIST traceable reference passing fuel cap of
nominal 52 to 56 cc/min for daily test verification;
4) Supplied with a NIST traceable reference failing fuel cap of
nominal 64 to 68 cc/min for daily test verification;
5) Accurate to 3 cc/min at the 60 min flow standard; and
6) Able to be modified, either by the manufacturer or an
authorized service center, to test at a revised leakage (flow) rate from that
originally shipped.