35 Ill. Adm. Code 276.606
On-Road Remote Sensing Test Systems Maintenance and Calibration
Section 276
Section 276.606 On-Road
Remote Sensing Test Systems Maintenance and Calibration
a) All equipment utilized for on-road remote sensing emission
measurement shall be maintained and calibrated according to the manufacturer's
specifications.
b) The accuracy of the Infrared SDM shall be verified by
measuring the concentration of tri-blend (CO
2
, HC, CO) calibration
gas released from a specially modified vehicle. A two point gas calibration
procedure shall be followed. The span shall be accomplished at the following
pair of span points:
300 – ppm
propane (HC)
1.0 – percent
CO
6.0 – percent
CO
2
1200 – ppm
propane (HC)
4.0 – percent
CO
12.0 – percent
CO
2
The Infrared SDM shall measure the span gas within the
allowable tolerance range specified in Section 276.507(b) of this Part.