35 Ill. Adm. Code 304.120
Deoxygenating Wastes
Section 304
Section 304.120Â
Deoxygenating Wastes
Except as provided in 35 Ill.
Adm. Code 306.Subpart C, all effluents containing deoxygenating wastes must
meet the following standards:
a)Â Â Â Â Â Â Â Â Effluents must not exceed 30 mg/L of five-day biochemical
oxygen demand (BOD
5
) or 30 mg/L of suspended solids, except that
treatment works employing three-stage lagoon treatment systems which are
properly designed, maintained and operated, and whose effluent has a dilution
ratio no less than five to one or who qualify for exceptions under subsection
(c) must not exceed 37 mg/L of suspended solids.
b)Â Â Â Â Â Â Â Â Effluents from any source whose untreated waste load is 10,000
population equivalents or more, or from any source discharging into the Chicago
River System or the Calumet River System, must not exceed 20 mg/L of BOD
5
or 25 mg/L of suspended solids.
c)Â Â Â Â Â Â Â Â Effluents whose dilution ratio is less than five to one must
not exceed 10 mg/L of BOD
5
or 12 mg/L of suspended solids, except
that sources employing third-stage treatment lagoons are be exempt from this
subsection (c) provided all of the following conditions are met:
1)Â Â Â Â Â Â Â Â The waste source qualifies under one of the following
categories:
A)Â Â Â Â Â Â Â Any wastewater treatment works with an untreated waste load
less than 2500 population equivalents, which is sufficiently isolated that
combining with other sources to aggregate 2500 population equivalents or more
is not practicable.
B)Â Â Â Â Â Â Â Any wastewater treatment works in existence and employing
third-stage treatment lagoons on January 1, 1986, whose untreated waste load is
5000 population equivalents or less and sufficiently isolated that combining to
aggregate 5000 population equivalents or more is not practicable.
C)Â Â Â Â Â Â Â Any wastewater treatment works with an untreated waste load of
5000 population equivalents or less, which has reached the end of its useful
life by January 1, 1987, and is sufficiently isolated that combining to
aggregate 5000 population equivalents or more is not practicable.
D)Â Â Â Â Â Â Â Any wastewater treatment works with an untreated waste load of
5000 population equivalents or less which has reached the end of its useful
life and which has received an adjusted standard determination from the Board
that it qualifies for a lagoon exemption. Such a Board determination will only
be made in an adjusted standard proceeding, held in compliance with Section
28.1 of the Environmental Protection Act [415 ILCS 5/28.1] and applicable
procedures at 35 Ill. Adm. Code 104.
i)Â Â Â Â Â Â Â Â Â In an adjusted standard proceeding the Board may determine
that the petitioning wastewater treatment source qualifies for a lagoon
exemption if the wastewater treatment works proves that it is so situated that
a land treatment system is not a suitable treatment alternative. Factors
relevant to a suitability finding may include the following:Â cost; influent
character; geographic characteristics; climate; soil conditions; hydrologic
conditions; and the availability of irrigable land.
ii)Â Â Â Â Â Â Â Â For subsection (c)(1)(D), a land treatment system is a
wastewater treatment system that does not directly discharge treated effluent into
the waters of the State but instead uses the treated effluent to irrigate
terrestrial vegetation;
2)Â Â Â Â Â Â Â Â The lagoons are properly constructed, maintained and operated;
and
3)Â Â Â Â Â Â Â Â The deoxygenating constituents of the effluent do not, alone
or in combination with other sources, cause a violation of the applicable
dissolved oxygen water quality standard.
d)Â Â Â Â Â Â Â Â Effluents discharged to the Lake Michigan basin must not
exceed 4 mg/L of BOD
5
or 5 mg/L of suspended solids.
e)Â Â Â Â Â Â Â Â Compliance with the numerical standards in this Section must
be determined based on the type and frequency of sampling prescribed by the
NPDES permit for the discharge at the time of monitoring.
f)Â Â Â Â Â Â Â Â For this Section, useful life is the period of time during
which it is cost-effective to operate and maintain a particular wastewater
treatment works under consideration. At a minimum, the following factors
relating to a wastewater treatment works must be considered in determining its
useful life:
1)Â Â Â Â Â Â Â Â Structural and operational condition of components;
2)Â Â Â Â Â Â Â Â Past operations and maintenance records;
3)Â Â Â Â Â Â Â Â Cost for continued use; and
4)Â Â Â Â Â Â Â Â Description and costs of treatment alternatives.
g)Â Â Â Â Â Â Â Â Compliance with the five-day biochemical oxygen demand (BOD
5
)
numerical standard in this Part will be determined by the analysis of five-day
carbonaceous biochemical oxygen demand (CBOD
5
), unless federal
regulations require treatment works treating industrial wastes to comply with
more stringent requirements determined by the analysis of BOD
5
.
Effluent from the treatment works subject to the requirements of Section
304.120(a) must not exceed 25 mg/L CBOD
5
.