35 Ill. Adm. Code 310.233
Combined Waste Stream Formula
Section 310
Section 310.233 Combined Waste
Stream Formula
If process wastewater is mixed
prior to treatment with wastewaters other than those generated by the regulated
process, the Control Authority (or the industrial user with the written
concurrence of the Control Authority) must derive fixed alternative discharge
limits. When it is deriving alternative categorical limits, the Control
Authority must calculate both an alternative daily maximum value using the
daily maximum values specified in the appropriate categorical pretreatment
standards and an alternative consecutive sampling day average value using the
average monthly values specified in the appropriate categorical pretreatment
standards. The industrial user must comply with the alternative daily maximum
and average monthly limits fixed by the Control Authority until the Control
Authority modifies the limits or approves an industrial user modification
request. Modification is authorized whenever there is a material or
significant change in the values used in the calculation to fix alternative
limits for the regulated pollutant. An industrial user must immediately report
any such material or significant change to the Control Authority. If
appropriate, the Control Authority must calculate new alternative categorical
limits within 30 days.
a) Alternative Limit Calculation. For these formulas, the
"average daily flow" means a reasonable measure of the average daily
flow for a 30-day period. For new sources, flows must be estimated using
projected values. The Control Authority must derive the alternative limit for a
specified pollutant by the use of either of the following formulas:
1) Alternative Concentration Limit
C =
(T - D)
Σ
C
i
F
i
(T)
Σ
F
i
where
C
=
The alternative concentration
limit for the combined waste stream.
C
i
=
The categorical pretreatment
standard concentration limit for a pollutant in the regulated stream i.
F
i
=
The average daily flow (at
least a 30-day average) of stream i to the extent that it is regulated for
such pollutant.
"ΣG
i
"
The sum of the results of
calculation G for streams i = 1 to i = N.
N
=
The total number of regulated
streams.
T
=
The average daily flow (at
least a 30-day average) through the combined pretreatment facility (includes F
i
,
D and unregulated streams.
D
=
The average daily flow (at
least a 30-day average) from:
A) Boiler blowdown streams, non-contact cooling streams,
stormwater streams, and demineralizer backwash streams, subject to the proviso
of subsection (d);
B) Sanitary waste streams if such waste streams are not regulated
by a categorical pretreatment standard; and
C) From any process waste streams that were or could have been
entirely exempted from categorical pretreatment standards as specified in
subsection (e).
2) Alternative Mass Limit
M =
(T - D)
Σ
M
i
Σ
F
i
where
M
=
The alternative mass limit for
a pollutant in the combined waste stream.
M
i
=
The categorical pretreatment
standard mass limit for a pollutant in the regulated stream i (the
categorical pretreatment mass limit multiplied by the appropriate measure of
production).
F
i
=
The average daily flow (at
least a 30-day average) of stream i to the extent that it is regulated for
such pollutant.
"ΣG
i
"
means the sum of the results
of calculation G for streams i = 1 to i = N.
N
=
The total number of regulated
streams.
T
=
The average daily flow (at
least a 30-day average) through the combined pretreatment facility (includes F
i
,
D and unregulated streams.
D
=
The average daily flow (at
least a 30-day average) from:
A) Boiler blowdown streams, non-contact cooling streams,
stormwater streams and demineralizer backwash streams, subject to the proviso
of subsection (d);
B) Sanitary waste streams if such waste streams are not regulated
by a categorical pretreatment standard; and
C) From any process waste streams that were or could have been entirely
exempted from categorical pretreatment standards, as specified in subsection
(e).
b) Alternative Limits Below Detection. An alternative
pretreatment limit must not be used if the alternative limit is below the
analytical detection limit for any of the regulated pollutants.
c) Self-monitoring. Self-monitoring required to ensure
compliance with the alternative categorical limit must be as follows:
1) The type and frequency of sampling, analysis, and flow
measurement must be determined by reference to the self-monitoring requirements
of the appropriate categorical pretreatment standards.
2) If the self-monitoring schedules for the appropriate standards
differ, monitoring must be done according to the most frequent schedule.
3) If flow determines the frequency of self-monitoring in a
categorical pretreatment standard, the sum of all regulated flows (F
i
)
is the flow that must be used to determine self-monitoring frequency.
d) Proviso to Subsections (a)(1) and (a)(2). If boiler blowdown,
non-contact cooling streams, stormwater streams, and demineralizer backwash
streams contain a significant amount of a pollutant, and the combination of
such streams, prior to pretreatment, with the industrial user's regulated
process waste streams will result in a substantial reduction of that pollutant,
the Control Authority, upon application of the industrial user, must determine
whether such waste streams should be classified as diluted or unregulated. In
its application to the Control Authority, the industrial user must provide
engineering, production, sampling, and analysis and such other relevant information
so the Control Authority can make its determination.
e) Exemptions from Categorical Pretreatment Standards. Process waste
streams were or could have been entirely exempted from categorical pretreatment
standards pursuant to paragraph 8 of the NRDC v. Costle consent decree,
incorporated by reference in Section 310.107, for one or more of the following
reasons (see appendix D to 40 CFR 403, incorporated by reference in Section
310.107):
1) The pollutants of concern are not detectable in the discharge
from the industrial user;
2) The pollutants of concern are present only in trace amounts
and are neither causing nor are likely to cause toxic effects;
3) The pollutants of concern are present in amounts too small to
be effectively reduced by technologies known to USEPA;
4) The waste stream contains only pollutants that are compatible
with the POTW.
f) If a treated regulated process waste stream is combined prior
to treatment with wastewaters other than those generated by the regulated
process, the industrial user may monitor either the segregated process waste
stream or the combined waste stream to determine compliance with applicable
pretreatment standards. If the industrial user chooses to monitor the
segregated process waste stream, it must apply the applicable categorical pretreatment
standard. If the user chooses to monitor the combined waste stream, it must
apply an alternative discharge limit calculated using the combined waste stream
formula as provided in this Section. The industrial user may change monitoring
points only after receiving approval from the Control Authority. The Control
Authority must ensure that any change in an industrial user's monitoring point
or points will not allow the user to substitute dilution for adequate treatment
to achieve compliance with applicable standards.
BOARD NOTE: Derived from 40 CFR 403.6(e) (2005), as amended at 70 Fed.
Reg. 60134 (Oct. 14, 2005).