35 Ill. Adm. Code 352.412
Conversion Factors for Dissolved and Total Metals
Section 352
Section 352.412 Conversion
Factors for Dissolved and Total Metals
a) The numeric standards for certain metal parameters in 35 Ill.
Adm. Code 302.504 are established as dissolved forms of the substance since the
dissolved form more closely relates to the toxicology literature utilized in
deriving the standard. However, most discharge monitoring data used in deriving
a PEQ will be from a total recoverable analytical method and permit limits if
and when established will be set at total recoverable to accommodate the total
recoverable analytical method. The Agency will use a conversion factor to
determine the amount of total metal corresponding to dissolved metal for each
metal with a water quality standard set at dissolved concentration. In the
absence of facility specific data the following default conversion factors will
be used for both PEQ derivation and establishing WQBELs. The conversion factor
represents the portion of the total recoverable metal presumed to be in
dissolved form. The conversion values given in the following table are
multiplied by the appropriate total recoverable metal concentration to obtain a
corresponding dissolved concentration which then may be compared to the acute
or chronic standard. A dissolved metal concentration may be divided by the
conversion factor to obtain a corresponding total metal value which will
generally be the metal form regulated in NPDES permits.
Metal
Conversion
Factor Acute Standard
Chronic
Standard
Arsenic
1.000
1.000
Cadmium
0.850
0.850
Chromium (Trivalent)
0.316
0.860
Chromium (Hexavalent)
0.982
0.962
Copper
0.960
0.960
Mercury
0.850
0.850
Nickel
0.998
0.997
Selenium
0.922
0.922
Zinc
0.978
0.986
b) A permittee may propose an alternate conversion factor for any
particular site specific application. The request must contain sufficient site
specific data, or other data that is representative of the site, to identify a
representative ratio of the dissolved fraction to the total recoverable
fraction of the metal in the receiving water body at the edge of the mixing
zone. If a site specific conversion factor is approved, that factor will be
used for PEQ derivation and establishment of a WQBEL in lieu of its default
counterpart in subsection (a) above.