35 Ill. Adm. Code 352.600
Mass Loading Limits
Section 352
Section 352.600 Mass Loading
Limits
Whenever a water quality based
effluent limitation (WQBEL) is established in a permit, the WQBEL shall be
expressed as both a concentration value and a corresponding mass loading rate.
a) Both mass and concentration limits shall be based on the same
permit averaging periods such as daily or monthly averages, or in other
appropriate permit averaging periods.
b) The mass based WQBEL shall be calculated using effluent flow
rates that are the same as those used in establishing the concentration-based
WQBEL.
c) Mass load limits are not required for parameters which cannot
be appropriately expressed in terms of mass as listed below:
pH
temperature
radiation
bacteria
dissolved oxygen
d) Discharges that are subject to substantial flow variation
such as wet weather flows or varied production schedules may have mass limits
established in a tiered fashion coinciding with different flow regimes.
Typically two tiered mass limits will be established. One set shall be based on
dry-weather effluent flowrate and the appropriate stream design flow. The
second mass limit shall be based on effluent and stream flowrates
representative of wet weather conditions.