35 Ill. Adm. Code 502.840
Technical Evaluation
Section 502.840 Technical Evaluation
All technical evaluations conducted under this Subpart
H must address the minimum elements contained in this Section. Waste
management and storage facilities designed, constructed, operated, and
maintained consistent with the analysis conducted in subsections (a) through
(g) and operated in accordance with the additional measures and records
required by Section 502.610 will fulfill this Subpart.
a) Information to
be used in the design of the open manure storage structure including:
1) Minimum storage
periods for rainy seasons;
2) Additional minimum
capacity for chronic rainfalls;
3) Applicable
technical standards that prohibit or otherwise limit land application on
frozen, saturated, or snow-covered ground found in Section 502.630;
4) Planned emptying
and dewatering schedules consistent with the CAFO's nutrient management plan;
5) Additional
storage capacity for livestock waste intended to be transferred to another
recipient at a later time; and
6) Any other
factors that would affect the sizing of the structure.
b) The design of
the open livestock waste storage structure as determined under 40 CFR
412.46(a)(1)(ii), incorporated by reference at 35 Ill. Adm. Code 501.200, or
equivalent design software or procedures approved by the Agency.
BOARD NOTE: NRCS Animal Waste Management (AWM) software
specified under 40 CFR 412.46(a)(1)(ii) is available at http://www.nrcs.usda.gov.
Additional information may be obtained from the United States Department of
Agriculture, Agricultural Research Service, 1400 Independence Avenue, S.W.,
Washington DC 20250, (202) 720-3656.
c) All inputs used
in the open livestock waste storage structure design, including:
1) actual climate
data for the previous 30 years, consisting of historical average monthly
precipitation and evaporation values;
2) the number and
types of animals;
3) anticipated
animal sizes or weights;
4) any added water
and bedding;
5) any other
process wastewater; and
6) the size and
condition of outside areas exposed to rainfall and contributing runoff to the
open livestock waste storage structure.
d) The planned
minimum period of storage in months, including the factors for designing an
open livestock waste storage structure described in subsection (a).
Alternatively, the CAFO may determine the minimum period of storage by
specifying times the storage pond will be emptied consistent with the CAFO's
nutrient management plan.
e) Site-specific
predicted design specifications, including:
1) dimensions of
the storage facility;
2) daily manure and
wastewater additions;
3) the size and characteristics
of the land application areas; and
4) the total
calculated storage period in months.
f) An evaluation of
the adequacy of the designed manure storage structure under 40 CFR
412.46(a)(1)(vi), incorporated by reference at 35 Ill. Adm. Code 501.200.
1) The evaluation
must include all inputs used in the simulation, including:
A) daily
precipitation, temperature, and evaporation data for the previous 100 years;
B) user-specified
soil profiles representative of the CAFO's land application areas;
C) planned crop
rotations consistent with the CAFO's nutrient management plan; and
D) the final modeled
result of no overflows from the designed open livestock waste storage
structure.
2) For those CAFOs
where 100 years of local weather data for the CAFO's location is not available,
CAFOs may use a simulation with a confidence interval analysis conducted over a
period of 100 years.
3) The adequacy of
the designed manure storage structure may be evaluated using equivalent
evaluation and simulation procedures the Agency approves.
BOARD NOTE: The Soil Plant Air Water (SPAW)
Hydrology Tool specified at 40 CFR 412.46(a)(1)(vi) is available at https://www.nrcs.usda.gov/resources/tech-tools/spaw-version-602.
Additional information may be obtained from the United States Department of Agriculture,
Agricultural Research Service, 1400 Independence Avenue, S.W., Washington DC 20250,
(202) 720-3656.
g) The
Agency may waive the requirement in subsection (f) for a site-specific
evaluation of the designed livestock waste storage structure and instead
authorize a CAFO to use a technical evaluation developed for a class of
specific facilities within a specified geographical area.
h) The Agency may
request additional information to support a request for livestock waste
discharge limitations based on a site-specific open surface livestock waste
storage structure.