35 Ill. Adm. Code 506.210
Secondary Containment
Section 506
Section 506.210 Secondary
Containment
Despite
any other requirement
of this subpart or 8 Ill. Adm. Code 900, every earthen livestock waste lagoon
constructed
under
this subpart
must
include the construction of a
secondary berm, filter strip, grass waterway, or terrace, or any combination of
those, outside the perimeter of the primary berm if an engineer licensed under
the Professional Engineering Practice Act of 1989 and retained by the
registrant determines, with the concurrence of the department, that
construction of such a secondary berm or other feature or features is necessary
in order to ensure against a release of livestock waste from the lagoon that
encroaches or is reasonably expected to encroach upon land other than the land
occupied by the livestock waste handling facility of which the lagoon is a
part; or that enters or is reasonably expected to enter the waters of this state
;
or that enters or may reasonably be expected to enter a natural depression in a
karst area and must be so designed. [510 ILCS 77/15(a)] The following criteria
must be incorporated into the design of a system used for secondary
containment:
a) A grass waterway constructed, installed, or used for this
Section must meet or exceed the following:
1) A grass waterway must be designed and constructed to transfer
the maximum expected flow rate of livestock waste that may reasonably be
expected to be released from the lagoon;
2) A grass waterway must direct the flow of livestock waste away
from the lagoon berm to a filter strip, secondary berm, terrace, or combination
of these; and
3) Vegetation must be established and maintained to provide
adequate ground cover.
b) A filter strip constructed, installed, or used for this
Section must meet or exceed the following:
1) A filter strip must be designed and constructed to function at
the maximum expected hydraulic loadings that may reasonably be expected to come
from the lagoon; and
2) Vegetation must be established and maintained to provide
adequate ground cover.
c) A secondary berm constructed, installed, or used for this
Section must meet or exceed the following:
1) The storage volume created due to the construction of a
secondary berm must be of sufficient capacity to contain the portion of the
lagoon liquid that may reasonably be expected to be released from the lagoon
plus any accumulated precipitation; and
2) A vegetative cover must be established. The area must be
maintained by periodic mowing, the removal of woody plant species, or other
measures to prevent erosion and berm deterioration.
d) A terrace constructed, installed, or used for this Section must
meet or exceed the following:
1) The terrace must direct the livestock waste to a filter strip
or grass waterway constructed or installed under this Section; and
2) Vegetation must be established and maintained to provide
adequate ground cover on those portions of the terrace where crops are not
grown.
e) The owner or operator of the earthen livestock lagoon may,
upon written request and with written approval from the Department, modify or
exceed the standards of this Section to meet site specific objectives. The
owner or operator must demonstrate that such modification will be at least as
protective of the groundwater, the surface water, and the structural integrity
of the livestock waste management facility as the requirements of this Part.