35 Ill. Adm. Code 506.303
Non-lagoon Livestock Waste Storage Volume Requirements
Section 506
Section 506.303Â Non-lagoon
Livestock Waste Storage Volume Requirements
a)Â Â Â Â Â Â Â Â Livestock waste handling facilities
that handle waste in a
liquid or semi-solid form
must
be designed to contain a volume of
at
least
the amount of waste generated during 150 days of facility operation at
design capacity.
[510 ILCS 77/13(a)(1)(B)] In addition, the design and
volume of livestock waste storage structures that handle waste in a liquid or
semi-solid form must include the following:
1)Â Â Â Â Â Â Â Â Runoff volumes generated during a 150-day period, including
all runoff and precipitation from lots, roofs, and other surfaces where
precipitation is directed into the storage structure. In no case must this
volume be less than the precipitation and runoff generated by a 25-year,
24-hour storm event and directed to the livestock waste handling facility;
2)Â Â Â Â Â Â Â Â The volume of all washdown liquid generated during the 150-day
period that is directed into the livestock waste handling facility; and
3)Â Â Â Â Â Â Â Â A freeboard of 2 feet, except for structures with a cover or
otherwise protected from precipitation.
b)Â Â Â Â Â Â Â Â Livestock waste handling facilities that handle waste in a
solid form must
be sized to store
at least
the amount of waste
generated during 6 months of facility operation at design capacity.
[510
ILCS 77/14(a)(4)]
c)Â Â Â Â Â Â Â Â Pump stations, settling tanks, pumps, piping, or other
components of a livestock waste handling facility that temporarily hold or
transport waste to a storage facility sized under this Section are exempt from
the storage volume requirements of this Section.
d)Â Â Â Â Â Â Â Â The design of any livestock waste storage structure required
to incorporate a freeboard under subsection (a) must include a liquid level
board or staff gauge. The liquid level board or staff gauge must include a
mark corresponding to the summation of the livestock waste volume and the
additional washdown volume under subsection (a) and must be designated as the
"START PUMPING" elevation.