35 Ill. Adm. Code 506.305
Additional Concrete Design and Construction Standards
Section 506
Section 506.305Â Additional
Concrete Design and Construction Standards
a)Â Â Â Â Â Â Â Â In addition to the requirements in Section 506.304, the design
and construction of concrete components of livestock waste handling facilities must
meet the following requirements:
1)Â Â Â Â Â Â Â Â Construction joints must be incorporated into the concrete in compliance
with the design guidance provided in MidWest Plan Service Concrete Manure
Storages Handbook, MWPS-36, or, in the case of circular concrete tanks,
Circular Concrete Manure Tanks, TR-9;
2)Â Â Â Â Â Â Â Â Water stops must be incorporated into construction joints in compliance
with the design guidance provided in MidWest Plan Service Concrete Manure
Storages Handbook, MWPS-36, or, in the case of circular concrete tanks,
Circular Concrete Manure Tanks, TR-9;
3)Â Â Â Â Â Â Â Â Concrete minimum compressive strength requirements must comply
with the design guidance provided in Table 28 of MidWest Plan Service Concrete
Manure Storages Handbook, MWPS-36, or, in the case of circular concrete tanks,
Table 1 of Circular Concrete Manure Tanks, TR-9; and
4)Â Â Â Â Â Â Â Â The strength, cover, and bending requirements for concrete
reinforcement must comply with the design guidance provided in Table 1 of
MidWest Plan Service Concrete Manure Storages Handbook, MWPS-36, or, in the
case of circular concrete tanks, Circular Concrete Manure Tanks, TR-9.
b)Â Â Â Â Â Â Â Â The owner or operator of the livestock waste handling facility
may, upon written request and with written approval from the Department, modify
or exceed these standards to meet site specific objectives. The owner or
operator must demonstrate that such modification will be at least as protective
of the groundwater, the surface water, and the structural integrity of the
livestock waste handling facility as the requirements of this Part.