35 Ill. Adm. Code 570.203
Planning Considerations
Section 570
Section 570.203 Planning
Considerations
The following shall be evaluated
in planning a runoff field application system:
a) Slopes and soil material, vegetative species, and time of year
for proper establishment of vegetation. Also consider the necessity for
irrigation of the field application area, visual aspects, and other special
needs.
b) Location of settling basin.
c) Adequate drainage to insure satisfactory performance.
d) Provisions for preventing or designing for continuous or daily
discharge of liquid waste to the field application area (e.g., provide
temporary storage tanks for milking parlor wastewaters or provide alternate
field application areas).
e) Provisions to allow harvesting activities without causing
design or vegetative damage.
f) Provisions for excluding roof water and unpolluted surface
water from the settling basin and field application area.
g) The need to mechanically distribute the flow uniformly across
the top of the field application area.
h) Runoff field application systems designed to be located on
soils with infiltration rates outside the range of 1.0 to 6.0 inches per hour,
or that are otherwise designed or maintained such that the criteria contained
herein are not satisfied, shall be considered innovative designs subject to
Section 570.207.