35 Ill. Adm. Code 6150.615.204
Groundwater Monitoring System
Section 615
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE F: PUBLIC WATER SUPPLIES
CHAPTER I: POLLUTION CONTROL BOARD
PART 615 EXISTING ACTIVITIES IN A SETBACK ZONE OR REGULATED RECHARGE AREA
SECTION 615.204 GROUNDWATER MONITORING SYSTEM
Section 615.204 Groundwater
Monitoring System
a) Except as provided otherwise in subsection (b), the
groundwater monitoring system must consist of a sufficient number of wells,
installed at appropriate locations and depths to yield groundwater samples,
that:
1) Represent the quality of background water that has not been
affected by contamination from the facility or unit; and
2) Represent the quality of groundwater at the compliance point
or points.
b) If a potable water well or other water well can be used as a
monitoring well under this subsection, no additional monitoring wells are
required under this Section. A potable water well or other water well may be
used as a monitoring well if:
1) For a potable water well other than a community water supply
well, a construction report has been filed with the Illinois Department of
Public Health for such well, or such well has been located and constructed (or
reconstructed) to meet the Illinois Water Well Construction Code [415 ILCS 30]
and 35 Ill. Adm. Code 920;
2) For a
potable water supply well that was constructed before August 20, 1965, the
enactment of the Illinois Water Well Construction Code [415 ILCS 30], and meets
all of the following criteria:
A) Construction
must be done in a manner that will enable the collection of groundwater samples
that represent in situ groundwater conditions;
B) Casings and screens must be made from
durable material resistant to expected chemical or physical degradation that does
not interfere with the quality of groundwater samples being collected; and
C) The
annular space opposite the screened section of the well (i.e., the space
between the bore hole and well screen) must be filled with gravel or sand if
necessary to collect groundwater samples. The annular space above and below
the well screen must be sealed to prevent migration of water from adjacent
formations and the surface to the sampled depth.
3) For a water well other than a potable water well (e.g., a
livestock watering well or an irrigation well), the owner or operator of the
unit seeking to use the well as a monitoring well certifies to the Agency that
a construction report has been filed with the Illinois Department of Public
Health or the Illinois Department of Mines and Minerals for such well, or that
such well has been located and constructed (or reconstructed) to meet the
Illinois Water Well Construction Code [415 ILCS 30] and 35 Ill. Adm. Code 920;
and
4) The unit contains solely non-special waste if the unit is a
surface impoundment.
c) When a facility contains more than one unit, separate
groundwater monitoring systems are not required for each unit if provisions for
sampling the groundwater will enable detection and measurement of contaminants
that have entered the groundwater from all units.
d) All monitoring wells must meet the following requirements:
1) Construction must be done in a manner that will enable the
collection of groundwater samples;
2) Casings and screens must be made from durable material that is
resistant to expected chemical or physical degradation and that does not
interfere with the quality of groundwater samples being collected; and
3) The annular space opposite the screened section of the well
(i.e., the space between the bore hole and well screen) must be filled with
gravel or sand if necessary to collect groundwater samples. The annular space
above and below the well screen must be sealed to prevent migration of water
from overlying adjacent formations and the surface to the sampled depth.