35 Ill. Adm. Code 6110.611.276
Recycle Provisions
Section 611
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE F: PUBLIC WATER SUPPLIES
CHAPTER I: POLLUTION CONTROL BOARD
PART 611 PRIMARY DRINKING WATER STANDARDS
SECTION 611.276 RECYCLE PROVISIONS
Section 611.276 Recycle
Provisions
a) Applicability. A Subpart B system supplier employing
conventional filtration or direct filtration treatment that recycles spent
filter backwash water, thickener supernatant, or liquids from dewatering
processes must comply with subsections (b) through (d).
b) Reporting. A supplier must notify the Agency in writing if
the supplier recycles spent filter backwash water, thickener supernatant, or
liquids from dewatering processes. This notification must minimally include
the information subsections (b)(1) and (b)(2) specify:
1) A plant schematic showing the origin of all recycled flows
(including spent filter backwash water, thickener supernatant, and liquids from
dewatering processes), the hydraulic conveyance used to transport these fluids,
and the location where the supplier reintroduces these fluids back into the
treatment plant.
2) The typical recycle flow in gallons per minute (gpm), the
highest plant flow the supplier observed in the previous year (gpm), design
flow for the treatment plant (gpm), and the Agency-approved operating capacity
for the plant if the Agency makes this determination.
c) Treatment Technique Requirement. Any supplier recycling spent
filter backwash water, thickener supernatant, or liquids from dewatering
processes must return these flows through the processes of the supplier's
existing conventional filtration or direct filtration system, as defined in
Section 611.101, or at an alternative location approved by a permit issued by
the Agency.
d) Recordkeeping. The supplier must collect and keep on file the
recycle flow information subsections (d)(1) through (d)(6) specify for review and
evaluation by the Agency:
1) A copy of the recycle notification and information the
supplier submitted to the Agency under subsection (b).
2) A list of all recycle flows and the frequency with which the
supplier returns them.
3) The average and maximum backwash flow rate through the filters
and the average and maximum filter backwash process duration in minutes.
4) The typical filter run length and a written summary of how
filter the run length is determined.
5) The type of treatment the supplier provides for the recycle
flow.
6) Data on the physical dimensions of the equalization or
treatment units, typical and maximum hydraulic loading rates, type of treatment
chemicals used and average dose and frequency of use, and the frequency at
which the supplier removes solids if applicable.
BOARD NOTE: This
Section derives from 40 CFR 141.76.