35 Ill. Adm. Code 6110.611.802
Groundwater Source Microbial Monitoring and Analytical Methods
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE F: PUBLIC WATER SUPPLIES
CHAPTER I: POLLUTION CONTROL BOARD
PART 611 PRIMARY DRINKING WATER STANDARDS
SECTION 611.802 GROUNDWATER SOURCE MICROBIAL MONITORING AND ANALYTICAL METHODS
Section 611.802 Groundwater Source Microbial Monitoring
and Analytical Methods
a) Triggered
Source Water Monitoring
1) General
Requirements. A GWS supplier must conduct triggered source water monitoring if
the following conditions exist.
A) The
supplier does not provide at least 4-log treatment of viruses (using
inactivation, removal, or an Agency-approved combination of 4-log virus inactivation
and removal) before or at the first customer for each groundwater source.
B) This
subsection (a)(1)(B) corresponds with 40 CFR 141.802(a)(1)(ii), which has no
operative effect after a past implementation date. This statement maintains
structural consistency with the federal regulations.
C) The
system is notified that a sample collected under Sections 611.1054 through
611.1057 is total coliform-positive and the sample is not invalidated under
Section 611.1053(c).
2) Sampling
Requirements. A GWS supplier must collect, within 24 hours after notification
of the total coliform-positive sample, at least one groundwater source sample
from each groundwater source in use at the time the total coliform-positive
sample was collected under Sections 611.1054 through 611.1057, except as
provided in subsection (a)(2)(B).
A) The
Agency may issue a SEP extending the 24-hour time limit on a case-by-case basis
if it determines that the supplier cannot collect the groundwater source water
sample within 24 hours due to circumstances beyond the supplier's control. In
the case of an extension, the Agency must specify how much time the supplier
has to collect the sample.
B) If
approved by the Agency, a supplier with more than one groundwater source may
meet the requirements of this subsection (a)(2) by sampling a representative
groundwater source or sources. If directed by the Agency in a SEP, the
supplier must submit for Agency approval a triggered source water monitoring
plan that identifies one or more groundwater sources that are representative of
each monitoring site in the system's sample siting plan under Section 611.1053
and that the system intends to use for representative sampling under this
subsection (a).
C) This
subsection (a)(2)(C) corresponds with 40 CFR 141.802(a)(1)(ii), a now-obsolete
implementing provision. This statement maintains structural consistency with
the federal regulations.
D) A GWS supplier serving 1,000 or fewer people
may use a repeat sample collected from a groundwater source to meet both the
requirements of Subpart AA and to satisfy the monitoring requirements of
subsection (a)(2) for that groundwater source only if the Agency issues a SEP
approving the use of E. coli as a fecal indicator for source water monitoring under
this subsection (a) and approves the use of a single sample for meeting both
the triggered source water monitoring requirements in this subsection (a) and
the repeat monitoring requirements in Section 611.1058. If the repeat sample
collected from the groundwater source is E. coli-positive, the system must
comply with subsection (a)(3).
3) Additional
Requirements. If the Agency does not require corrective action under Section
611.803(a)(2) for a fecal indicator-positive source water sample collected under
subsection (a)(2) that is not invalidated under subsection (d), the supplier
must collect five additional source water samples from the same source within
24 hours after being notified of the fecal indicator-positive sample.
4) Consecutive
and Wholesale Systems
A) In
addition to the other requirements of this subsection (a), a consecutive GWS
supplier that has a total coliform-positive sample collected under Sections
611.1054 through 611.1057, must notify the wholesale systems within 24 hours
after being notified of the total coliform-positive sample.
B) In
addition to the other requirements of this subsection (a), a wholesale GWS
supplier must comply with the following requirements:
i) A
wholesale GWS supplier that receives notice from a consecutive system it serves
that a sample collected under Sections 611.1054 through 611.1057 is total
coliform-positive must, within 24 hours after being notified, collect a sample
from its groundwater sources under subsection (a)(2) and analyze it for a fecal
indicator under subsection (c).
ii) If
the sample collected under subsection (a)(4)(B)(i) is fecal indicator-positive,
the wholesale GWS supplier must notify all consecutive systems served by that
groundwater source of the fecal indicator source water positive within 24 hours
after being notified of the groundwater source sample monitoring result and
must meet the requirements of subsection (a)(3).
5) Exceptions
to the Triggered Source Water Monitoring Requirements. A GWS supplier is not
required to comply with the source water monitoring requirements of subsection
(a) if either of the following conditions exists:
A) The
Agency issues a SEP determining and documenting that a distribution system
deficiency caused the total coliform-positive sample collected under Sections
611.1054 through 611.1057; or
B) The
total coliform-positive sample collected under Sections 611.1054 through
611.1057 is collected at a location that meets Agency criteria for distribution
system conditions that will cause total coliform-positive samples.
b) Assessment
Source Water Monitoring. If the Agency directs in a SEP, a GWS supplier must
conduct assessment source water monitoring that meets Agency-determined
requirements for such monitoring. A GWS supplier conducting assessment source
water monitoring may use a triggered source water sample collected under
subsection (a)(2) to meet the requirements of subsection (b).
Agency-determined assessment source water monitoring requirements may include
the following:
1) Collection
of a total of 12 groundwater source samples that represent each month the
system provides groundwater to the public;
2) Collection
of samples from each well, unless the system obtains written Agency approval to
conduct monitoring at one or more wells within the GWS that are representative
of multiple wells used by that system and that draw water from the same
hydrogeologic setting;
3) Collection
of a standard sample volume of at least 100 mL for fecal indicator analysis,
regardless of the fecal indicator or analytical method used;
4) Analysis
of all groundwater source samples using one of the analytical methods listed in
subsection (c)(2) for the presence of E. coli, enterococci, or coliphage;
5) Collection
of groundwater source samples at a location prior to any treatment of the
groundwater source unless the Agency approves a sampling location after
treatment; and
6) Collection
of groundwater source samples at the well itself, unless the system's
configuration does not allow for sampling at the well itself and the Agency
approves in a SEP an alternate sampling location that is representative of the
water quality of that well.
c) Analytical
Methods
1) A GWS
supplier subject to the source water monitoring requirements of subsection (a)
must collect a standard sample volume of at least 100 mL for fecal indicator
analysis, regardless of the fecal indicator or analytical method used.
2) A GWS
supplier must analyze all groundwater source samples collected under subsection
(a) using one of the analytical methods listed in subsections (c)(2)(A) through
(c)(2)(C), each incorporated by reference in Section 611.102, or alternative methods
approved by the Agency under Section 611.480, subject to the limitations of
subsection (c)(2)(D), for the presence of E. coli, enterococci, or coliphage:
A) E.
coli. Enzyme Substrate Technique
i) Colilert
®
.
SM 9223 B (97), SM 9223 B (04), or SM 9223 B (16).
ii) Colisure
®
.
SM 9223 B (97), SM 9223 B (04), or SM 9223 B (16).
iii) Membrane
Filter Method with MI Agar. USEPA 1604 (02).
iv) E*Colite
(98).
v) EC-MUG.
SM 9221 F (94), SM 9221 F (06), or SM 9221 F (14).
vi) NA-MUG.
SM 9222 G (97) (20
th
ed. only) or SM 9222 I (15), SM 9222 I (22).
vii) Colilert
®
-18.
SM 9223 B (97), SM 9223 B (04), or SM 9223 B (16).
viii) Readycult
®
(07).
ix) Modified
Colitag™ (09) or Modified Colitag™ (20).
x) Chromocult
®
(00).
xi) Tecta
(14) or Tecta (17).
xii)
RAPID'E. coli (20)
.
BOARD NOTE: EC-MUG (
SM
9221 F (94) (20
th
ed. only)) or NA-MUG (SM 9222
G (97) (20
th
ed. only)), both incorporated by reference in Section
611.102, can be used for E. coli testing step, as described in 40 CFR
141.21(f)(6)(i) or (f)(6)(ii), incorporated by reference in Section 611.102, after
use of SM 9221 B (93), SM 9221 B (94), SM 9221 B (99), SM 9221 B (06), SM 9221
D (93), SM 9221 D (94), SM 9221 D (99), SM 9221 D (06), SM 9222 B (91), SM 9222
B (94), SM 9222 B (97), SM 9222 C (91), SM 9222 C (94), or SM 9222 C (97).
B) E.
coli. Fermentation Technique
i) Hach 10029 (99) (m-ColiBlue24
®
).
ii) SM 9222 J (15), SM 9222 J (22).
C) Enterococci
i) Multiple-Tube
Technique. SM 9230 B (93) (20
th
ed. only), SM 9230 B (04), SM 9230 B
(13), SM 9230 B (22), SM 9230 C (93) (20
th
ed. only), SM 9230 C
(13), SM 9230 C (22), or USEPA 1600 (02).
BOARD NOTE: The holding time and temperature
for groundwater samples are specified in subsection (c)(2)(D), rather than as
specified in Section 8 of USEPA 1600 (02).
ii) Fluorogenic
Substrate Enterococcus Test (using Enterolert). Enterolert (96), SM 9230 D (13),
or SM 9230 D (22).
BOARD NOTE: Medium is available
through IDEXX Laboratories, Inc., at the address in Section 611.102(b).
Preparation and use of the medium must be as stated in the article that
embodies the method as incorporated by reference in Section 611.102(b).
D) Coliphage
i) Two-Step
Enrichment Presence-Absence Procedure. USEPA 1601 (01) or Charm Fast Phage (12).
ii) Single
Agar Layer Procedure. USEPA 1602 (01).
E) Limitation
on Methods Use. The time from sample collection to initiation of analysis may
not exceed 30 hours. The GWS supplier is encouraged but is not required to
hold samples below 10° C during transit.
d) Invalidation
of a Fecal Indicator-Positive Groundwater Source Sample
1) A GWS
supplier may obtain Agency invalidation of a fecal indicator-positive
groundwater source sample collected under subsection (a) only under either of
the following conditions:
A) The
supplier provides the Agency with written notice from the laboratory that
improper sample analysis occurred; or
B) The
Agency issues a SEP determining and documenting that substantial evidence that
a fecal indicator-positive groundwater source sample is not related to source
water quality.
2) If
the Agency invalidates a fecal indicator-positive groundwater source sample,
the GWS supplier must collect another source water sample under subsection (a)
within 24 hours after being notified by the Agency of its invalidation
decision, and the supplier must have it analyzed for the same fecal indicator
using the analytical methods in subsection (c). The Agency may extend the
24-hour time limit on a case-by-case basis if the supplier cannot collect the
source water sample within 24 hours due to circumstances beyond its control.
In the case of an extension, the Agency must specify how much time the system
has to collect the sample.
e) Sampling
Location
1) Any
groundwater source sample required under subsection (a) must be collected at a
location prior to any treatment of the groundwater source unless the Agency
approves a sampling location after treatment.
2) If
the supplier's system configuration does not allow for sampling at the well
itself, it may collect a sample at an Agency-approved location to meet the
requirements of subsection (a) if the sample is representative of the water
quality of that well.
f) New Sources.
If the Agency directs in a SEP, a GWS supplier placing a new groundwater source
into service must conduct assessment source water monitoring under subsection
(b). If the SEP directs, the supplier must begin monitoring before the
groundwater source is used to provide water to the public.
g) Public
Notification. A GWS supplier with a groundwater source sample collected under
subsection (a) or (b) that is fecal indicator-positive and that is not
invalidated under subsection (d), including a consecutive system supplier
served by the groundwater source, must conduct public notification under
Section 611.902.
h) Monitoring
Violations. A failure to meet the requirements of subsections (a) through (f)
is a monitoring violation that requires the GWS supplier to provide public
notification under Section 611.904.
BOARD NOTE:
This Section derives
from 40 CFR 141.402 and
appendix A to subpart C of 40 CFR 141. The Board did not separately list
approved alternative methods from Standard Methods Online that are the same
version as a method appearing in a printed edition of Standard Methods. Using
the Standard Methods Online copy is acceptable.
Standard Methods Online, Method
9221 F-06
appears in the 22
nd
edition as
Method 9221 F. This appears in this Section as SM 9221 F (06).
Standard Methods Online, Method
9222 G-97
appears in the 20
th
and 21
st
editions as Method 9222 G. This appears in this Section as SM 9222 G (97).
Standard Methods Online, Method
9223 B-97
appears in the 20
th
and 21
st
editions as Method 9223 B. This appears in this Section as SM 9223 B (97).
Standard Methods Online, Method
9223 B-04
appears in the 22
nd
edition as
Method 9223 B. This appears in this Section as SM 9223 B (04).