35 Ill. Adm. Code 611.1009
Disinfection Profiling and Benchmarking Requirements: Developing the Disinfection Profile and Benchmark
Section 611.1009 Disinfection Profiling and Benchmarking
Requirements: Developing the Disinfection Profile and Benchmark
a) A
supplier required to develop disinfection profiles under Section 611.1008 must
follow the requirements of this Section. The supplier must monitor at least
weekly for a period of 12 consecutive months to determine the total log
inactivation for Giardia lamblia and viruses. If the supplier monitors more
frequently than weekly, the monitoring frequency must be evenly spaced. A
supplier that operates for fewer than 12 months per year must monitor weekly
during the period of operation. A supplier must determine log inactivation for
Giardia lamblia through the entire plant, based on the applicable CT
99.9
values in Appendix B. A supplier must determine log inactivation for viruses
through the entire treatment plant based on a protocol approved by the Agency
by a SEP.
b) A
supplier with a single point of disinfectant application prior to the entrance
to the distribution system must conduct the monitoring in subsections (b)(1)
through (b)(4). A supplier with more than one point of disinfectant
application must conduct the monitoring in subsections (b)(1) through (b)(4)
for each disinfection segment. A supplier must monitor the parameters
necessary to determine the total inactivation ratio, using analytical methods
in Section 611.531.
1) For a
supplier using a disinfectant other than UV, the temperature of the disinfected
water must be measured at each residual disinfectant concentration sampling
point during peak hourly flow or at an alternative location approved by the
Agency by a SEP.
2) For a
supplier using chlorine, the pH of the disinfected water must be measured at
each chlorine residual disinfectant concentration sampling point during peak
hourly flow or at an alternative location approved by the Agency by a SEP.
3) The
disinfectant contact times (t) must be determined during peak hourly flow.
4) The
residual disinfectant concentrations (C) of the water before or at the first
customer and prior to each additional point of disinfectant application must be
measured during peak hourly flow.
c) In
lieu of conducting new monitoring under subsection (b), a supplier may elect to
meet the following requirements:
1) A
supplier that has at least one year of existing data that are substantially
equivalent to data collected under the provisions of subsection (b) may use
these data to develop disinfection profiles as specified in this Section if the
supplier has neither made a significant change to its treatment practice nor
changed sources since the data were collected. The supplier may develop
disinfection profiles using up to three years of existing data.
2) A
supplier may use disinfection profiles developed under Section 611.742 or Section
611.953 in lieu of developing a new profile if the supplier has neither made a
significant change to its treatment practice nor changed sources since the
profile was developed. A supplier that has not developed a virus profile under
Section 611.742 or Section 611.953 must develop a virus profile using the same
monitoring data on which the Giardia lamblia profile is based.
d) A
supplier must calculate the total inactivation ratio for Giardia lamblia, as
specified in subsections (d)(1) through (d)(3).
1) A
supplier using only one point of disinfectant application may determine the
total inactivation ratio for the disinfection segment based on either of the
following methods:
A) It may
determine one inactivation ratio (Ai) before or at the first customer during
peak hourly flow; or
B) It may
determine successive Ai values, representing sequential inactivation ratios,
between the point of disinfectant application and a point before or at the
first customer during peak hourly flow. The supplier must calculate the total
inactivation ratio by determining Ai for each sequence and then adding the Ai
values together to determine the total inactivation ratio (Σ Ai).
2) A
supplier using more than one point of disinfectant application before the first
customer must determine the CT value of each disinfection segment immediately
prior to the next point of disinfectant application, or for the final segment,
before or at the first customer, during peak hourly flow. The Ai value of each
segment and Σ Ai must be calculated using the method in subsection
(d)(1)(B).
3) The
supplier must determine the total logs of inactivation by multiplying the value
calculated in subsection (d)(1) or (d)(2) by 3.0.
4) The
supplier must calculate the log of inactivation for viruses using a protocol
approved by the Agency by regulation or by a SEP.
e) A
supplier must use the following procedures to calculate a disinfection
benchmark:
1) For
each year of profiling data collected and calculated under subsections (a)
through (d), the supplier must determine the lowest mean monthly level of both
Giardia lamblia and virus inactivation. A supplier must determine the mean
Giardia lamblia and virus inactivation for each calendar month for each year of
profiling data by dividing the sum of daily or weekly Giardia lamblia and virus
log inactivation by the number of values calculated for that month.
2) The
disinfection benchmark is the lowest monthly mean value (for a supplier with
one year of profiling data) or the mean of the lowest monthly mean values (for
a supplier with more than one year of profiling data) of Giardia lamblia and
virus log inactivation in each year of profiling data.
BOARD NOTE: Derived from 40 CFR
141.709 (2016).