35 Ill. Adm. Code 611.1359
Analytical Methods
Section 611.1359Â Analytical Methods
The supplier must conduct analyses for lead, copper, pH,
conductivity, calcium, alkalinity, orthophosphate, silica, and temperature
using the methods in Section 611.611(a).
a)Â Â Â Â Â Â Â Â Only
a certified laboratory in one of the categories in Section 611.490(a) may
conduct analyses for lead and copper to demonstrate that a supplier complies
with this Subpart AG. To obtain certification for conducting analyses for lead
and copper, a laboratory must fulfill specific conditions:
1)Â Â Â Â Â Â Â Â The
laboratory must analyze lead- and copper-containing performance evaluation
samples provided by USEPA or the Agency;
2)Â Â Â Â Â Â Â Â The
laboratory must achieve certain quantitative acceptance limits:
A)Â Â Â Â Â Â Â For
lead: ±30 percent of the actual amount in the performance evaluation sample
when the actual amount is greater than or equal to 0.005 mg/L (the PQL for lead
is 0.005 mg/L);
B)Â Â Â Â Â Â Â For
copper: ±10 percent of the actual amount in the performance evaluation sample
when the actual amount is greater than or equal to 0.050 mg/L (the PQL for
copper is 0.050 mg/L);
3)Â Â Â Â Â Â Â Â The
laboratory must achieve the method detection limit (MDL) for lead of 0.001 mg/L
using the procedures in 35 Ill. Adm. Code 186 and appendix B to 40 CFR 136: "Definition
and Procedure for the Determination of the Method Detection Limit—Revision 1.11",
incorporated by reference in Section 611.102(c). The laboratory needs only
accomplish this if the laboratory will process source water composite samples
under Section 611.1358(a)(1)(D); and
4)Â Â Â Â Â Â Â Â The
laboratory must have current certification to perform analyses under the
specifications this subsection (a)(1) describes.
BOARD NOTE:Â This subsection (a)
corresponds with Section 611.359(a) and derives from 40 CFR 141.89(a) and
(a)(1) (2020).
b)Â Â Â Â Â Â Â Â The
Agency must issue a SEP allowing a supplier to use previously collected
monitoring data under this Subpart AG if the supplier collected and analyzed
the data complying with this Subpart AG.
BOARD NOTE:Â This subsection (b)
corresponds with Section 611.359(b) and derives from 40 CFR 141.89(a)(2)
(2020).
c)Â Â Â Â Â Â Â Â Reporting
Lead and Copper Levels
1)Â Â Â Â Â Â Â Â The
supplier must report all lead and copper levels greater than or equal to the
lead and copper PQL (Pb (0.005 mg/L and Cu (0.050 mg/L) as measured.
2)Â Â Â Â Â Â Â Â The
supplier must report all lead and copper levels less than the PQL but greater
than the MDL (0.005 mg/L > Pb > MDL and 0.050 mg/L > Cu > MDL)
either as measured or as one-half the PQL in subsection (a) (i.e., 0.0025 mg/L
for lead or 0.025 mg/L for copper).
3)Â Â Â Â Â Â Â Â The
supplier must report all lead and copper levels below the lead and copper MDL
(MDL > Pb) as zero.
BOARD NOTE:Â This subsection (c)
corresponds with Section 611.359(c) and derives from 40 CFR 141.89(a)(3) and
(a)(4) (2020).