35 Ill. Adm. Code 611.262
Filtered PWSs: Reporting and Recordkeeping
Section 611
Section 611.262 Filtered
PWSs: Reporting and Recordkeeping
A supplier using a surface water
source or a groundwater source under the direct influence of surface water that
provides filtration treatment must monthly report specific information to the
Agency.
a) The supplier must report turbidity measurements that Section
611.533(a) requires within ten days after the end of each month the supplier
serves water to the public. The report must include specific information:
1) The total number of filtered water turbidity measurements the
supplier took during the month.
2) The number and percentage of filtered water turbidity
measurements the supplier took during the month that are less than or equal to
the turbidity limits Section 611.250 specifies for the filtration technology the
supplier uses.
3) The date and value of any turbidity measurements the supplier
took during the month that exceed 5 NTU.
b) The supplier must report the disinfection information Section
611.533 specifies to the Agency within ten days after the end of each month the
supplier serves water to the public. The report must include specific
information:
1) For each day, the lowest RDC measurement (in mg/L) in water
entering the distribution system.
2) The date and duration of each period during which the RDC in
water entering the distribution system fell below 0.2 mg/L and when the
supplier notified the Agency of the occurrence.
3) Specific information on the samples the supplier took in the
distribution system for total coliform monitoring under Sections 611.240
through 611.242:
A) The number of times when the supplier measured the RDC;
B) The number of times when the supplier did not measure the RDC
but did measure HPC;
C) The number of times when the supplier measured but did not
detect RDC but did not measure HPC;
D) The number of times when the supplier measured but did not
detect the RDC, and the HPC is greater than 500/ml;
E) The number of times when the supplier did not measure the RDC,
and HPC is greater than 500/ml;
F) For the current and previous month the supplier serves water
to the public, the value of "V" in the following formula:
where:
a
=
The value
in subsection (b)(3)(A);
b
=
The value
in subsection (b)(3)(B);
c
=
The value
in subsection (b)(3)(C);
d
=
The value
in subsection (b)(3)(D); and
e
=
The value
in subsection (b)(3)(E).
G) Subsections
(b)(3)(A) through (b)(3)(F) do not apply if the Agency determines, under
Section 611.213, that a supplier has no means for having a sample analyzed for
HPC by a certified laboratory under the requisite time and temperature
conditions specified by Section 611.531(a) and that the supplier adequately
provides disinfection in the distribution system.
c) Reporting Health Threats
1) Upon discovering that a waterborne disease outbreak occurred
that is potentially attributable to its water system, a supplier must report
that occurrence to the Agency as soon as possible but no later than by the end
of the next business day.
2) If at any time the turbidity exceeds 5 NTU, the supplier must
consult with the Agency as soon as practical, but no later than 24 hours the
supplier knows of the exceedance, under Section 611.903(b)(3).
3) If at any time the RDC falls below 0.2 mg/L in the water
entering the distribution system, the supplier must notify the Agency as soon
as possible, but no later than by the end of the next business day. The
supplier must also notify the Agency by the end of the next business day
whether or not the supplier restored the to at least 0.2 mg/L within four
hours.
BOARD NOTE: This Section
derives from 40 CFR 141.75(b).