35 Ill. Adm. Code 615.723
Design and Operating Requirements
Section 615
Section 615.723 Design and
Operating Requirements
a) Indoor facilities must comply with the following standards
beginning two years after the date of first applicability:
1) The base of the facility must be constructed of materials
capable of containing de-icing agents (e.g., bituminous or concrete pad).
2) The roof and walls of the facility must be constructed of
materials capable of protecting the storage pile from precipitation and capable
of preventing dissolved de-icing agents from entering into the adjacent soil,
surface water, or groundwater. The walls of the facility must be constructed
of materials compatible with the de-icing agents to be placed in the facility.
Run-off from the roof must be diverted away from the loading pad.
3) All areas surrounding the storage pile, including the loading
pad, must be routinely inspected to determine whether any release of de-icing
agents has occurred. Such areas must be cleaned as necessary. Spilled de-icing
agents must be placed back under the protective covering of the indoor storage
pile. The storage pile must be reshaped as often as necessary to prevent
leaching.
4) The integrity of the facility and loading pad must be
maintained.
5) All areas surrounding the storage facility must be inspected
daily to determine whether any release of de-icing agents has occurred.
Spilled de-icing agents must be placed back into the storage facility.
b) Outdoor facilities or units must comply with the following
standards beginning two years after the date of first applicability:
1) An impermeable membrane or cover must be placed over all
storage piles to protect the piles from precipitation and surface water
run-on. The membrane or cover must prevent runoff and leachate from being
generated by the outdoor storage piles. The piles must be formed in a conical
shape, covered, and stored on a paved pad capable of preventing leachate from
entering adjacent soil, surface water, or groundwater.
2) Surface drainage must be directed to prevent flow through the
base of the storage piles. De-icing agents must not be stored where drainage may
enter into water supplies, farm lands, or streams.
3) All areas surrounding the storage piles must be cleaned and
must be inspected daily to determine whether any release of de-icing agents has
occurred. Spilled de-icing agents must be placed back under the protective
covering of the outdoor storage piles. The storage piles must be reshaped as
often as necessary to prevent leaching.
4) The storage piles must be designed and operated to control
wind dispersal of the product by means other than wetting.