35 Ill. Adm. Code 7030.703.201
Containers
Section 703
TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE G: WASTE DISPOSAL
CHAPTER I: POLLUTION CONTROL BOARD
SUBCHAPTER b: PERMITS
PART 703 RCRA PERMIT PROGRAM
SECTION 703.201 CONTAINERS
Section 703.201 Containers
For a facility that stores containers
of hazardous waste, except as otherwise provided in 35 Ill. Adm. Code 724.270,
the Part B application must include the following:
a) A description of the containment system to demonstrate
compliance with 35 Ill. Adm. Code 724.275. Show at least the following:
1) Basic design parameters, dimensions, and materials of
construction;
2) How the design promotes drainage or how containers are kept
from contact with standing liquids in the containment system;
3) Capacity of the containment system relative to the number and
volume of containers to be stored;
4) Provisions for preventing or managing run-on; and
5) How accumulated liquids can be analyzed and removed to prevent
overflow.
b) For storage areas that store containers holding wastes that do
not contain free liquids, a demonstration of compliance with 35 Ill. Adm. Code
724.275(c), including the following:
1) Test procedures and results or other documentation or
information to show that the wastes do not contain free liquids; and
2) A description of how the storage area is designed or operated
to drain and remove liquids or how containers are kept from contact with
standing liquids.
c) Sketches, drawings, or data demonstrating compliance with 35
Ill. Adm. Code 724.276 (location of buffer zone and containers holding
ignitable or reactive wastes) and 35 Ill. Adm. Code 724.277(c) (location of
incompatible wastes), where applicable.
d) Where incompatible wastes are stored or otherwise managed in
containers, a description of the procedures used to ensure compliance with 35
Ill. Adm. Code 724.117(b) and (c) and 724.277(a) and (b).
e) Information on air emission control equipment, as required in
Section 703.213.
BOARD NOTE: Derived from 40 CFR 270.15 (2002).