35 Ill. Adm. Code 620.310

Preventive Response Activities

Last amended: 2025Year: 2026Length: 956 wordsOfficial source
Section 620 Section 620.310  Preventive Response Activities a)         The following preventive assessment must be undertaken: 1)         If a preventive notification under Section 620.305(c) is provided by a community water supply: A)        The Agency must notify the owner or operator of any identified potential primary source, potential secondary source, potential route, or community water supply well that is within 2,500 feet of the wellhead. B)        The owner or operator notified under subsection (a)(1)(A) must, within 30 days after the date of issuance of that notice, sample each water well or monitoring well for the contaminant identified in the notice if the contaminant or material containing the contaminant is or has been stored, disposed of, or otherwise handled at the site.  If a contaminant identified under Section 620.305(a) is detected, then the well must be resampled within 30 days after the date on which the first sample results are received.  If a contaminant identified under Section 620.305(a) is detected by the resampling, preventive notification must be given as specified in Section 620.305. C)        If the Agency receives analytical results under subsection (a)(1)(B) that show a contaminant identified under Section 620.305(a) has been detected, the Agency must: i)          Conduct a well site survey under Section 17.1(d) of the Act [415 ILCS 5/17.1(d)] if one has not been conducted within the last 5 years; and ii)         Identify those sites or activities that represent a hazard to the continued availability of groundwaters for public use unless a groundwater protection needs assessment has been prepared under Section 17.1(d) of the Act. 2)         If a preventive notification is provided under Section 620.305(c) by a non-community water supply or for multiple private water supply wells, the Department of Public Health must conduct a sanitary survey within 1,000 feet of the wellhead of a non-community water supply or within 500 feet of the wellheads for multiple private water supply wells. 3)         If a preventive notification under Section 620.305(b) is provided by the owner or operator of a regulated entity and the applicable standard of Subpart D has not been exceeded, the appropriate regulatory agency must: A)        Determine if any of the following occurs for Class I:  Potable Resource Groundwater: i)          The levels specified below are exceeded or are changed for pH: CASRN Constituent Criteria (mg/L) 95-50-1 o -Dichlorobenzene (1,2-dichlorobenzene) 0.01 1634-04-4 MTBE methyl tertiary butyl ether 0.02 108-95-2 Phenols 0.001 100-42-5 Styrene 0.01 108-88-3 Toluene 0.04 1330-20-7 Xylenes 0.02 ii)         A statistically significant increase occurs above background (as determined under other regulatory procedures (e.g., 35 Ill. Adm. Code 616, 724, 725, or 811)) for the following inorganic constituents (except due to natural causes) or organic constituents: CASRN Inorganics Constituent 7429-90-5 Aluminum 7440-38-2 Arsenic 7440-41-7 Beryllium 7440-43-9 Cadmium 7440-47-3 Chromium (total) 143-33-9 Cyanide 7439-92-1 Lead 7487-94-7 Mercury (mercuric chloride) 7439-98-7 Molybdenum 7440-28-0 Thallium 7440-62-2 Vanadium Organics 83-32-9 Acenaphthene 67-64-1 Acetone 116-06-3 Aldicarb 120-12-7 Anthracene 319-84-6 alpha-BHC (alpha- benzene hexachloride) 1912-24-9 Atrazine and metabolites DEA, DIA, DACT 71-43-2 Benzene 56-55-3 Benzo(a)anthracene 205-99-2 Benzo(b)fluoranthene 207-08-9 Benzo(k)fluoranthene 50-32-8 Benzo(a)pyrene 65-85-0 Benzoic acid 78-93-3 2-Butanone (methyl ethyl ketone) 1563-66-2 Carbofuran 75-15-0 Carbon disulfide 56-23-5 Carbon tetrachloride 12789-03-6 Chlordane 108-90-7 Chlorobenzene 67-66-3 Chloroform 218-01-9 Chrysene 94-75-7 2.4-D (2.4-dichlorophenoxy acetic acid) 75-99-0 Dalapon 96-12-8 1,2-Dibromo-3-chloropropane (dibromochloroorooane) 1918-00-9 Dicamba 106-46-7 p -Dichlorobenzene (1,4-dichlorobenzene) 75-71-8 Dichlorodifluoromethane 75-34-3 1,1-Dichloroethane 75-35-4 1,1-Dichloroethylene 107-06-2 1,2-Dichloroethane 156-59-2 cis -1,2-Dichloroethylene 156-60-5 trans -1,2-Dichloroethylene 75-09-2 Dichloromethane (methylene 78-87-5 1,2-Dichloropropane 117-81-7 Di(2-ethylhexyl)phthalate 84-66-2 Diethyl phthalate 84-74-2 Di- n -butyl phthalate 99-65-0 1,3-Dinitrobenzene 121-14-2 2,4-Dinitrotoluene 88-85-7 Dinoseb 123-91-1 1,4-Dioxane ( p dioxane) 145-73-3 Endothall 72-20-8 Endrin 100-41-4 Ethylbenzene 106-93-4 Ethylene dibromide (1,2-dibromoethane) 206-44-0 Fluoranthene 86-73-7 Fluorene 58-89-9 gamma-HCH ( gamma -hexachlorocyclohexane lindane) 13252-13-6 HFPO-DA (hexafluoropropylene oxide dimer acid, GenX) 2691-41-0 HMX (octahydro-1,3,5,7-tetranitro-1, 3, 5, 7-tetrazocine) 76-44-8 Heptachlor 1024-57-3 Heptachlor epoxide 77-47-4 Hexachlorocyclopentadiene 193-39-5 Indeno(l,2,3-c,d)pyrene 98-82-8 Isopropylbenzene (cumene) 72-43-5 Methoxychlor 90-12-0 1-Methylnaphthalene 91-57-6 2-Methylnaphthalene 95-48-7 2-Methylphenol ( o -cresol) 91-20-3 Naphthalene 98-95-3 Nitrobenzene 1336-36-3 PCBs (polychlorinated biphenyls as decachloro-biphenyl) 375-73-5 PFBS (perfluorobutanesulfonic acid) 355-46-4 PFHxS (perfluorohexanesulfonic acid) 375-95-1 PFNA (perfluorononanoic acid) 335-67-1 PFOA (perfluorooctanoic acid) 1763-23-1 PFOS (perfluorooctanesulfonic acid) 87-86-5 Pentachlorophenol 1918-02-1 Picloram 129-00-0 Pyrene 121-82-4 RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine) 122-34-9 Simazine 118-96-7 TNT (2,4,6-trinitrotoluene) 93-72-1 2,4,5-TP (silvex) 127-18-4 Tetrachloroethylene 8001-35-2 Toxaphene 120-82-1 1,2,4-Trichlorobenzene 71-55-6 1,1,1-Trichloroethane 79-00-5 1,1,2-Trichloroethane 79-01-6 Trichloroethylene 75-69-4 Trichlorotluoromethane 99-35-4 1,3,5-Trinitrobenzene 75-01-4 Vinyl chloride iii)        For a chemical constituent of gasoline, diesel fuel, or heating fuel, the constituent exceeds the following: Constituent Criterion (mg/L) BETX 0.095 iv)        For pH, a statistically significant change occurs from background. B)        Determine if, for Class III:  Special Resource Groundwater, the levels as determined by the Board are exceeded. C)        Consider whether the owner or operator reasonably demonstrates that: i)          The contamination is a result of contaminants remaining in groundwater from a prior release for which appropriate action was taken in compliance with laws and regulations in existence at the time of the release; ii)         The source of contamination is not due to the on-site release of contaminants; or iii)        The detection resulted from error in sampling, analysis, or evaluation. D)        Consider actions necessary to minimize the degree and extent of contamination. b)         The appropriate regulatory agency must determine whether a preventive response should be undertaken based on relevant factors, including the considerations in subsection (a)(3). c)         After completion of preventive response under the authority of an appropriate regulatory agency, the concentration of a contaminant specified in subsection (a)(3)(A) in groundwater may exceed 50% of the applicable numerical standard of Subpart D if the following conditions are met: 1)         The exceedance has been minimized to the extent practicable; 2)         Beneficial use, as appropriate for the class of groundwater, has been assured; and 3)         Any threat to public health or the environment has been minimized. d)         Nothing in this Section limits the authority of the State or the United States to require or perform any corrective action process.
35 Ill. Adm. Code 620.310: Preventive Response Activities | Justis AI