Section 670.501 Waste Piles
a) Containment
A waste pile (except for an existing portion of a waste pile)
must have a liner that is designed, constructed and installed to prevent any
migration of wastes out of the pile into the adjacent subsurface soil or
groundwater or surface water at any time during the active life (including the
closure period) of the waste pile. The liner may be constructed of materials
that may allow waste to migrate into the liner itself (but not into the
adjacent subsurface soil or groundwater or surface water) during the active
life of the facility. The liner must be:
1) Constructed of materials that have appropriate chemical
properties and sufficient strength and thickness to prevent failure due to
pressure gradients (including static head and external hydrogeologic forces),
physical contact with the waste or leachate to which they are exposed, climatic
conditions, the stress of installation and the stress of daily operation;
2) Placed upon a foundation or base capable of providing support
to the liner and resistance to pressure gradients above and below the liner to
prevent failure of the liner due to settlement, compression or uplift; and
3) Installed to cover all surrounding earth likely to be in
contact with the waste or leachate.
b) Management of Waste Piles
The owner or operator of any waste pile that is inside or
under a structure that provides protection from precipitation so that neither
run-off nor leachate is generated is not subject to regulation provided that:
1) Liquids or materials containing free liquids are not placed in
the pile;
2) The pile is protected from surface water run-on by the
structure or in some other manner;
3) The pile is designed and operated to control dispersal of the
waste by wind, where necessary, by means other than wetting; and
4) The pile will not generate leachate through decomposition or
other reaction.
c) Closure
The owner or operator must remove or decontaminate all
residues, contaminated containment system components (liners, etc),
contaminated subsoils and structures and contaminated equipment.