35 Ill. Adm. Code 703.212
Drip Pads
Section 703
Section 703.212 Drip Pads
Except as otherwise provided by
35 Ill. Adm. Code 724.101, the owner or operator of a hazardous waste
treatment, storage, or disposal facility that collects, stores, or treats
hazardous waste on drip pads must provide the following additional information:
a) A
list of hazardous wastes placed or to be placed on each drip pad.
b) If an exemption is sought to Subpart F of 35 Ill. Adm. Code
724, as provided by 35 Ill. Adm. Code 724.190, detailed plans and an
engineering report describing how the requirements of 35 Ill. Adm. Code
724.190(b)(2) will be met.
c) Detailed plans and an engineering report describing how the
drip pad is or will be designed, constructed, operated, and maintained to meet
the requirements of 35 Ill. Adm. Code 724.673, including the as-built drawings
and specifications. This submission must address the following items, as
specified in 35 Ill. Adm. Code 724.671:
1) The design characteristics of the drip pad;
2) The liner system;
3) The leakage detection system, including the leak detection
system and how it is designed to detect the failure of the drip pad or the
presence of any releases of hazardous waste or accumulated liquid at the
earliest practicable time;
4) Practices designed to maintain drip pads;
5) The associated collection system;
6) Control of run-on to the drip pad;
7) Control of run-off from the drip pad;
8) The interval at which drippage and other materials will be
removed from the associated collection system and a statement demonstrating
that the interval will be sufficient to prevent overflow onto the drip pad;
9) Cleaning procedures and documentation:
A) Procedures for cleaning the drip pad at least once every seven
days to ensure the removal of any accumulated residues of waste or other
materials, including, but not limited to: rinsing, washing with detergents or
other appropriate solvents, or steam cleaning; and
B) Provisions for documenting the date, time, and cleaning
procedure used each time the pad is cleaned;
10) Operating practices and procedures that will be followed to
ensure that tracking of hazardous waste or waste constituents off the drip pad
due to activities by personnel or equipment is minimized;
11) Procedures for ensuring that, after removal from the
treatment vessel, treated wood from pressure and non-pressure processes is held
on the drip pad until drippage has ceased, including recordkeeping practices;
12) Provisions for ensuring that collection and holding units
associated with the run-on and run-off control systems are emptied or otherwise
managed as soon as possible after storms to maintain design capacity of the
system;
13) If treatment is carried out on the drip pad, details of the
process equipment used, and the nature and quality of the residuals;
14) A description of how each drip pad, including appurtenances
for control of run-on and run-off, will be inspected in order to meet the
requirements of 35 Ill. Adm. Code 724.673. This information must be included
in the inspection plan submitted under Section 703.183(e);
15) A certification signed by a qualified Professional Engineer,
stating that the drip pad design meets the requirements of 35 Ill. Adm. Code 724.673(a)
through (f); and
16) A description of how hazardous waste residues and
contaminated materials will be removed from the drip pad at closure, as
required under 35 Ill. Adm. Code 724.675(a). For any waste not to be removed
from the drip pad upon closure, the owner or operator must submit detailed
plans and an engineering report describing how 35 Ill. Adm. Code 724.410(a) and
(b) will be complied with. This information must be included in the closure
plan and, where applicable, the post-closure plan submitted under Section
703.183(m).
BOARD NOTE: Derived from 40 CFR
270.26 (2007).