35 Ill. Adm. Code 724.115
General Inspection Requirements
Section 724
Section 724.115 General
Inspection Requirements
a) The owner or operator must conduct inspections often enough to
identify problems in time to correct them before they harm human health or the
environment. The owner or operator must inspect the facility for malfunctions
and deterioration, operator errors, and discharges that may be causing or may
lead to either of the following:
1) Release
of hazardous waste constituents to the environment; or
2) A
threat to human health.
b) Inspection
Schedule
1) The owner or operator must develop and follow a written
schedule for inspecting monitoring equipment, safety and emergency equipment,
security devices, and operating and structural equipment (such as dikes and
sump pumps) that are important to preventing, detecting, or responding to
environmental or human health hazards.
2) The
owner or operator must keep this schedule at the facility.
3) The schedule must identify the types of problems (e.g.,
malfunctions or deterioration) that are to be looked for during the inspection
(e.g., inoperative sump pump, leaking fitting, eroding dike, etc.).
4) The
frequency of inspection may vary for the items on the schedule. However, the
frequency should be based on the rate of deterioration of the equipment and the
probability of an environmental or human health incident if the deterioration,
malfunction, or operator error goes undetected between inspections. Areas
subject to spills, such as loading and unloading areas, must be inspected daily
when in use. At a minimum, the inspection schedule must include the items and
frequencies called for in Sections 724.274, 724.293, 724.295, 724.326, 724.354,
724.378, 724.403, 724.447, 724.702, 724.933, 724.952, 724.953, 724.958, and
724.983 through 724.990, where applicable. 35 Ill. Adm. Code 703 requires the
inspection schedule to be submitted with Part B of the permit application. The
Agency must evaluate the schedule, along with the rest of the application, to
ensure that it adequately protects human health and the environment. As part
of this review, the Agency may modify or amend the schedule as may be
necessary.
c) The owner or operator must remedy any deterioration or
malfunction of equipment or structures that the inspection reveals on a
schedule which ensures that the problem does not lead to an environmental or
human health hazard. Where a hazard is imminent or has already occurred,
remedial action must be taken immediately.
d) The owner or operator must record inspections in an inspection
log or summary. The owner or operator must keep these records for at least
three years from the date of inspection. At a minimum, these records must
include the date and time of the inspection, the name of the inspector, a
notation of the observations made and the date, and nature of any repairs or
other remedial actions.