35 Ill. Adm. Code 724.275
Containment
Section 724
Section 724.275Â Containment
a)Â Â Â Â Â Â Â Â Container storage areas must have a containment system that is
designed and operated in accordance with subsection (b), except as otherwise
provided by subsection (c);
b)Â Â Â Â Â Â Â Â A containment system must be designed and operated as follows:
1)Â Â Â Â Â Â Â Â A base must underlie the containers that is free of cracks or
gaps and is sufficiently impervious to contain leaks, spills, and accumulated
precipitation until the collected material is detected and removed.
2)Â Â Â Â Â Â Â Â The base must be sloped or the containment system must be
otherwise designed and operated to drain and remove liquids resulting from
leaks, spills, or precipitation, unless the containers are elevated or are
otherwise protected from contact with accumulated liquids;
3)Â Â Â Â Â Â Â Â The containment system must have sufficient capacity to
contain 10 percent of the volume of containers or the volume of the largest
container, whichever is greater. Containers that do not contain free liquids
need not be considered in this determination;
4)Â Â Â Â Â Â Â Â Run-on into the containment system must be prevented, unless
the collection system has sufficient excess capacity in addition to that
required in subsection (b)(3) to contain any run-on that might enter the system;
and
5)Â Â Â Â Â Â Â Â Spilled or leaked waste and accumulated precipitation must be
removed from the sump or collection area in as timely a manner as is necessary
to prevent overflow of the collection system.
BOARD NOTE:Â
If the collected material is a hazardous waste, it must be managed as a
hazardous waste in accordance with all applicable requirements of 35 Ill. Adm.
Code 722 through 728. If the collected material is discharged through a point
source to waters of the State, it is subject to the National Pollution
Discharge Elimination System (NPDES) permit requirement of Section 12(f) of the
Environmental Protection Act and 35 Ill. Adm. Code 309.102.
c)Â Â Â Â Â Â Â Â Storage areas that store containers holding only wastes that
do not contain free liquids need not have a containment system defined by subsection
(b), except as provided by subsection (d), or provided as follows:
1)Â Â Â Â Â Â Â Â That the storage area is sloped or is otherwise designed and
operated to drain and remove liquid resulting from precipitation, or
2)Â Â Â Â Â Â Â Â That the containers are elevated or are otherwise protected
from contact with accumulated liquid.
d)Â Â Â Â Â Â Â Â Storage areas that store containers holding the wastes listed
below that do not contain free liquids must have a containment system defined
by subsection (b): F020, F021, F022, F023, F026, and F027.