35 Ill. Adm. Code 724.354
Monitoring and Inspection
Section 724
Section 724.354Â Monitoring
and Inspection
a)Â Â Â Â Â Â Â Â During construction or installation, liners (except in the
case of existing portions of piles exempt from Section 724.351(a)) and cover
systems (e.g., membranes, sheets or coatings) must be inspected for uniformity,
damage, and imperfections (e.g., holes, cracks, thin spots, or foreign
materials). Immediately after construction or installation, the following must
be done:
1)Â Â Â Â Â Â Â Â Synthetic liners and covers must be inspected to ensure tight
seams and joints and the absence of tears, punctures, and blisters; and
2)Â Â Â Â Â Â Â Â Soil-based and admixed liners and covers must be inspected for
imperfections including lenses, cracks, channels, root holes, or other
structural non-uniformities that may cause an increase in the permeability of
the liner or cover.
b)Â Â Â Â Â Â Â Â While a waste pile is in operation, it must be inspected
weekly and after storms to detect evidence of any of the following:
1)Â Â Â Â Â Â Â Â Deterioration, malfunctions, or improper operation of run-on
and run-off control systems;
2)Â Â Â Â Â Â Â Â Proper functioning of wind dispersal control systems, where
present; or
3)Â Â Â Â Â Â Â Â The presence of leachate in and proper functioning of leachate
collection and removal systems, where present.
c)Â Â Â Â Â Â Â Â An owner or operator required to have a LDS under Section
724.351(c) must record the amount of liquids removed from each LDS sump at
least once each week during the active life and closure period.