35 Ill. Adm. Code 724.933
Standards: Closed-Vent Systems and Control Devices
Section 724
Section 724.933Â Standards:Â
Closed-Vent Systems and Control Devices
a)Â Â Â Â Â Â Â Â Compliance Required
1)Â Â Â Â Â Â Â Â Owners or operators of closed-vent systems and control devices
used to comply with provisions of this Part must comply with the provisions of
this Section.
2)Â Â Â Â Â Â Â Â Implementation Schedule
A)Â Â Â Â Â Â Â The owner or operator of an existing facility that cannot
install a closed-vent system and control device to comply with the provisions
of this Subpart AA on the effective date that the facility becomes subject to
the provisions of this Subpart AA must prepare an implementation schedule that
includes dates by which the closed-vent system and control device will be
installed and in operation. The controls must be installed as soon as
possible, but the implementation schedule may allow up to 30 months after the
effective date that the facility becomes subject to this Subpart AA for
installation and startup.
B)Â Â Â Â Â Â Â Any unit beginning operation that is subject to the provisions
of this Subpart AA when operation begins must comply with the rules immediately
(i.e., must have control devices installed and operating on startup of the
affected unit); the 30-month implementation schedule does not apply.
C)Â Â Â Â Â Â Â The owner or operator of any facility in existence on the
effective date of a statutory or regulatory amendment that renders the facility
subject to this Subpart AA must comply with all requirements of this Subpart AA
as soon as practicable, but no later than 30 months after the effective date of
the amendment. When control equipment required by this Subpart AA cannot be
installed and begin operation by the effective date of the amendment, the
facility owner or operator must prepare an implementation schedule that
includes the following information:Â specific calendar dates for award of
contracts or issuance of purchase orders for the control equipment, initiation
of on-site installation of the control equipment, completion of the control
equipment installation, and performance of any testing to demonstrate that the
installed equipment meets the applicable standards of this Subpart AA. The
owner or operator must enter the implementation schedule in the operating
record or in a permanent, readily available file located at the facility.
D)Â Â Â Â Â Â Â An owner or operator of a facility or unit that becomes newly
subject to the requirements of this Subpart AA due to an action other than
those described in subsection (a)(2)(C) must comply with all applicable
requirements immediately (i.e., the facility or unit must have control devices
installed and operating on the date the facility or unit becomes subject to
this Subpart AA; the 30-month implementation schedule does not apply).
b)Â Â Â Â Â Â Â Â A control device involving vapor recovery (e.g., a condenser
or adsorber) must be designed and operated to recover the organic vapors vented
to it with an efficiency of 95 weight percent or greater unless the total organic
emission limits of Section 724.932(a)(1) for all affected process vents is
attained at an efficiency less than 95 weight percent.
c)Â Â Â Â Â Â Â Â An enclosed combustion device (e.g., a vapor incinerator,
boiler, or process heater) must be designed and operated to reduce the organic
emissions vented to it by 95 weight percent or greater; to achieve a total
organic compound concentration of 20 ppmv, expressed as the sum of the actual
compounds and not in carbon equivalents, on a dry basis, corrected to three percent
oxygen; or to provide a minimum residence time of 0.50 seconds at a minimum
temperature of 760° C. If a boiler or process heater is used as the control
device, then the vent stream must be introduced into the flame zone of the
boiler or process heater.
d)Â Â Â Â Â Â Â Â Flares
1)Â Â Â Â Â Â Â Â A flare must be designed for and operated with no visible
emissions, as determined by the methods specified in subsection (e)(1), except
for periods not to exceed a total of five minutes during any two consecutive
hours.
2)Â Â Â Â Â Â Â Â A flare must be operated with a flame present at all times, as
determined by the methods specified in subsection (f)(2)(C).
3)Â Â Â Â Â Â Â Â A flare must be used only if the net heating value of the gas
being combusted is 11.2 MJ/scm (300 Btu/scf) or greater and the flare is
steam-assisted or air-assisted or if the net heating value of the gas being
combusted is 7.45 MJ/scm (200 Btu/scf) or greater and the flare is nonassisted.
The net heating value of the gas being combusted must be determined by the
methods specified in subsection (e)(2).
4)Â Â Â Â Â Â Â Â Exit Velocity
A)Â Â Â Â Â Â Â A steam-assisted or nonassisted flare must be designed for and
operated with an exit velocity, as determined by the methods specified in
subsection (e)(3), less than 18.3 m/s (60 ft/s), except as provided in
subsections (d)(4)(B) and (d)(4)(C).
B)Â Â Â Â Â Â Â A steam-assisted or nonassisted flare designed for and operated
with an exit velocity, as determined by the methods specified in subsection
(e)(3), equal to or greater than 18.3 m/s (60 ft/s) but less than 122 m/s (400
ft/s) is allowed if the net heating value of the gas being combusted is greater
than 37.3 MJ/scm (1,000 Btu/scf).
C)Â Â Â Â Â Â Â A steam-assisted or nonassisted flare designed for and operated
with an exit velocity, as determined by the methods specified in subsection
(e)(3), less than the velocity, V, as determined by the method specified in
subsection (e)(4), and less than 122 m/s (400 ft/s) is allowed.
5)Â Â Â Â Â Â Â Â An air-assisted flare must be designed and operated with an
exit velocity less than the velocity, V, as determined by the method specified
in subsection (e)(5).
6)Â Â Â Â Â Â Â Â A flare used to comply with this Section must be
steam-assisted, air-assisted, or nonassisted.
e)Â Â Â Â Â Â Â Â Compliance Determination and Equations
1)Â Â Â Â Â Â Â Â Reference Method 22 (Visual Determination of Fugitive
Emissions from Material Sources and Smoke Emissions from Flares) in appendix A
to 40 CFR 60 (Test Methods), incorporated by reference in 35 Ill. Adm. Code 720.111(b),
must be used to determine the compliance of a flare with the visible emission
provisions of this Subpart AA. The observation period is two hours and must be
used according to Reference Method 22.
2)Â Â Â Â Â Â Â Â The net heating value of the gas being combusted in a flare
must be calculated using the following equation:
H
T
=
K
x
n
Σ
i=1
C
i
x
H
i
Where:
H
T
=
the net heating value of the
sample in MJ/scm;Â where the net enthalpy per mole of offgas is based on
combustion at 25 °C and 760 mm Hg, but the standard temperature for
determining the volume corresponding to one mole is 20 °C
K
=
1.74 x -10
-7
(1/ppm)(g mol/scm)(MJ/kcal) where the standard temperature for (g mol/scm) is
20 °C
C
i
=
the concentration of sample
component i in ppm on a wet basis, as measured for organics by Reference
Method 18 (Measurement of Gaseous Organic Compound Emissions by Gas
Chromatography) in appendix A to 40 CFR 60 (Test Methods), and for carbon
monoxide, by ASTM D 1946-90 (Standard Practice for Analysis of Reformed Gas
by Gas Chromatography), each incorporated by reference in 35 Ill. Adm. Code
720.111
H
i
=
the net heat of combustion of
sample component i, kcal/gmol at 25 °C and 760 mm Hg. The heats of combustion
must be determined using ASTM D 2382-88 (Standard Test Method for Heat of
Combustion of Hydrocarbon Fuels by Bomb Calorimeter (High Precision Method)),
incorporated by reference in 35 Ill. Adm. Code 720.111(a), if published
values are not available or cannot be calculated
3)Â Â Â Â Â Â Â Â The actual exit velocity of a flare must be determined by
dividing the volumetric flow rate (in units of standard temperature and
pressure), as determined by Reference Methods 2 (Determination of Stack Gas
Velocity and Volumetric Flow Rate (Type S Pitot Tube)), 2A (Direct Measurement
of Gas Volume through Pipes and Small Ducts), 2C (Determination of Gas Velocity
and Volumetric Flow Rate in Small Stacks or Ducts (Standard Pitot Tube)), or 2D
(Measurement of Gas Volume Flow Rates in Small Pipes and Ducts) in appendix A
to 40 CFR 60 (Test Methods), incorporated by reference in 35 Ill. Adm. Code 720.111(b),
as appropriate, by the unobstructed (free) cross-sectional area of the flare
tip.
4)Â Â Â Â Â Â Â Â The maximum allowed velocity in m/s, V
max
, for a
flare complying with subsection (d)(4)(C) must be determined by the following
equation:
log
10
(V
max
)
=
H
T
+ 28.8
31.7
Where:
H
T
=
the net heating value as
determined in subsection (e)(2)
5)Â Â Â Â Â Â Â Â The maximum allowed velocity in m/s, V
max
, for an
air-assisted flare must be determined by the following equation:
V
max
=
8.706 Â + Â 0.7084Â H
T
Where:
H
T
=
the net heating value as
determined in subsection (e)(2)
f)Â Â Â Â Â Â Â Â The owner or operator must monitor and inspect each control
device required to comply with this Section to ensure proper operation and
maintenance of the control device by implementing the following requirements:
1)Â Â Â Â Â Â Â Â Install, calibrate, maintain, and operate according to the
manufacturer's specifications a flow indicator that provides a record of stream
flow from each affected process vent to the control device at least once every
hour. The flow indicator sensor must be installed in the vent stream at the
nearest feasible point to the control device inlet but before the point at
which the vent streams are combined.
2)Â Â Â Â Â Â Â Â Install, calibrate, maintain, and operate according to the
manufacturer's specifications a device to continuously monitor control device
operation, as follows:
A)Â Â Â Â Â Â Â For a thermal vapor incinerator, a temperature monitoring
device equipped with a continuous recorder. The device must have accuracy of ±1
percent of the temperature being monitored in °C or ±0.5°C, whichever is
greater. The temperature sensor must be installed at a location in the
combustion chamber downstream of the combustion zone.
B)Â Â Â Â Â Â Â For a catalytic vapor incinerator, a temperature monitoring
device equipped with a continuous recorder. The device must be capable of
monitoring temperature at two locations and have an accuracy of ±1 percent of
the temperature being monitored in °C or ±0.5° C, whichever is greater. One
temperature sensor must be installed in the vent stream at the nearest feasible
point to the catalyst bed inlet and a second temperature sensor must be
installed in the vent stream at the nearest feasible point to the catalyst bed
outlet.
C)Â Â Â Â Â Â Â For a flare, a heat sensing monitoring device equipped with a
continuous recorder that indicates the continuous ignition of the pilot flame.
D)Â Â Â Â Â Â Â For a boiler or process heater having a design heat input
capacity less than 44 MW, a temperature monitoring device equipped with a
continuous recorder. The device must have an accuracy of ±1 percent of the
temperature being monitored in °C or ±0.5° C, whichever is greater. The
temperature sensor must be installed at a location in the furnace downstream of
the combustion zone.
E)Â Â Â Â Â Â Â For a boiler or process heater having a design heat input
capacity greater than or equal to 44 MW, a monitoring device equipped with a
continuous recorder to measure parameters that indicate good combustion
operating practices are being used.
F)Â Â Â Â Â Â Â Â For a condenser, either of the following:
i)Â Â Â Â Â Â Â Â Â A monitoring device equipped with a continuous recorder to
measure the concentration level of the organic compounds in the exhaust vent
stream from the condenser; or
ii)Â Â Â Â Â Â Â Â A temperature monitoring device equipped with a continuous
recorder. The device must be capable of monitoring temperature with an accuracy
of ±1 percent of the temperature being monitored in °C or ±0.5° C, whichever is
greater. The temperature sensor must be installed at a location in the exhaust
vent stream from the condenser exit (i.e., product side).
G)Â Â Â Â Â Â Â For a carbon adsorption system that regenerates the carbon bed
directly in the control device such as a fixed-bed carbon adsorber, either of
the following:
i)Â Â Â Â Â Â Â Â Â A monitoring device equipped with a continuous recorder to
measure the concentration level of the organic compounds in the exhaust vent
stream from the carbon bed, or
ii)Â Â Â Â Â Â Â Â A monitoring device equipped with a continuous recorder to
measure a parameter that indicates the carbon bed is regenerated on a regular,
predetermined time cycle.
3)Â Â Â Â Â Â Â Â Inspect the readings from each monitoring device required by
subsections (f)(1) and (f)(2) at least once each operating day to check control
device operation and, if necessary, immediately implement the corrective
measures necessary to ensure the control device operates in compliance with the
requirements of this Section.
g)Â Â Â Â Â Â Â Â An owner or operator using a carbon adsorption system such as
a fixed-bed carbon adsorber that regenerates the carbon bed directly onsite in
the control device must replace the existing carbon in the control device with
fresh carbon at a regular, predetermined time interval that is no longer than
the carbon service life established as a requirement of Section
724.935(b)(4)(C)(vi).
h)Â Â Â Â Â Â Â Â An owner or operator using a carbon adsorption system such as
a carbon canister that does not regenerate the carbon bed directly onsite in
the control device must replace the existing carbon in the control device with
fresh carbon on a regular basis by using one of the following procedures:
1)Â Â Â Â Â Â Â Â Monitor the concentration level of the organic compounds in
the exhaust vent stream from the carbon adsorption system on a regular
schedule, and replace the existing carbon with fresh carbon immediately when
carbon breakthrough is indicated. The monitoring frequency must be daily or at
an interval no greater than 20 percent of the time required to consume the
total carbon working capacity established as a requirement of Section
724.935(b)(4)(C)(vii), whichever is longer.
2)Â Â Â Â Â Â Â Â Replace the existing carbon with fresh carbon at a regular,
predetermined time interval that is less than the design carbon replacement
interval established as a requirement of Section 724.935(b)(4)(C)(vii).
i)Â Â Â Â Â Â Â Â Â An alternative operational or process parameter may be
monitored if the operator demonstrates that the parameter will ensure that the
control device is operated in conformance with these standards and the control
device's design specifications.
j)Â Â Â Â Â Â Â Â Â An owner or operator of an affected facility seeking to
comply with the provisions of this Part by using a control device other than a
thermal vapor incinerator, catalytic vapor incinerator, flare, boiler, process
heater, condenser, or carbon adsorption system is required to develop
documentation including sufficient information to describe the control device
operation and identify the process parameter or parameters that indicate proper
operation and maintenance of the control device.
k)Â Â Â Â Â Â Â Â A closed-vent system must meet either of the following design
requirements:
1)Â Â Â Â Â Â Â Â A closed-vent system must be designed to operate with no
detectable emissions, as indicated by an instrument reading of less than 500
ppmv above background, as determined by the methods specified at Section
724.934(b), and by visual inspections; or
2)Â Â Â Â Â Â Â Â A closed-vent system must be designed to operate at a pressure
below atmospheric pressure. The system must be equipped with at least one
pressure gauge or other pressure measurement device that can be read from a
readily accessible location to verify that negative pressure is being
maintained in the closed-vent system when the control device is operating.
l)Â Â Â Â Â Â Â Â Â The owner or operator must monitor and inspect each
closed-vent system required to comply with this Section to ensure proper
operation and maintenance of the closed-vent system by implementing the
following requirements:
1)Â Â Â Â Â Â Â Â Each closed-vent system that is used to comply with subsection
(k)(1) must be inspected and monitored in accordance with the following
requirements:
A)Â Â Â Â Â Â Â An initial leak detection monitoring of the closed-vent system must
be conducted by the owner or operator on or before the date that the system
becomes subject to this Section. The owner or operator must monitor the
closed-vent system components and connections using the procedures specified in
Section 724.934(b) to demonstrate that the closed-vent system operates with no
detectable emissions, as indicated by an instrument reading of less than 500
ppmv above background.
B)Â Â Â Â Â Â Â After initial leak detection monitoring required in subsection
(l)(1)(A), the owner or operator must inspect and monitor the closed-vent
system as follows:
i)Â Â Â Â Â Â Â Â Â Closed-vent system joints, seams, or other connections that
are permanently or semi-permanently sealed (e.g., a welded joint between two
sections of hard piping or a bolted and gasketed ducting flange) must be
visually inspected at least once per year to check for defects that could
result in air pollutant emissions. The owner or operator must monitor a
component or connection using the procedures specified in Section 724.934(b) to
demonstrate that it operates with no detectable emissions following any time
the component is repaired or replaced (e.g., a section of damaged hard piping
is replaced with new hard piping) or the connection is unsealed (e.g., a flange
is unbolted).
ii)Â Â Â Â Â Â Â Â Closed-vent system components or connections other than those
specified in subsection (l)(1)(B)(i) must be monitored annually and at other
times as requested by the Regional Administrator, except as provided for in
subsection (o), using the procedures specified in Section 724.934(b) to
demonstrate that the components or connections operate with no detectable
emissions.
C)Â Â Â Â Â Â Â In the event that a defect or leak is detected, the owner or
operator must repair the defect or leak in accordance with the requirements of
subsection (l)(3).
D)Â Â Â Â Â Â Â The owner or operator must maintain a record of the inspection
and monitoring in accordance with the requirements specified in Section
724.935.
2)Â Â Â Â Â Â Â Â Each closed-vent system that is used to comply with subsection
(k)(2) must be inspected and monitored in accordance with the following
requirements:
A)Â Â Â Â Â Â Â The closed-vent system must be visually inspected by the owner
or operator to check for defects that could result in air pollutant emissions.
Defects include, but are not limited to, visible cracks, holes, or gaps in
ductwork or piping or loose connections.
B)Â Â Â Â Â Â Â The owner or operator must perform an initial inspection of the
closed-vent system on or before the date that the system becomes subject to
this Section. Thereafter, the owner or operator must perform the inspections at
least once every year.
C)Â Â Â Â Â Â Â In the event that a defect or leak is detected, the owner or
operator must repair the defect in accordance with the requirements of
subsection (l)(3).
D)Â Â Â Â Â Â Â The owner or operator must maintain a record of the inspection
and monitoring in accordance with the requirements specified in Section
724.935.
3)Â Â Â Â Â Â Â Â The owner or operator must repair all detected defects as
follows:
A)Â Â Â Â Â Â Â Detectable emissions, as indicated by visual inspection or by
an instrument reading greater than 500 ppmv above background, must be
controlled as soon as practicable, but not later than 15 calendar days after the
emission is detected, except as provided for in subsection (l)(3)(C).
B)Â Â Â Â Â Â Â A first attempt at repair must be made no later than five
calendar days after the emission is detected.
C)Â Â Â Â Â Â Â Delay of repair of a closed-vent system for which leaks have
been detected is allowed if the repair is technically infeasible without a
process unit shutdown, or if the owner or operator determines that emissions
resulting from immediate repair would be greater than the fugitive emissions
likely to result from delay of repair. Repair of such equipment must be
completed by the end of the next process unit shutdown.
D)Â Â Â Â Â Â Â The owner or operator must maintain a record of the defect
repair in accordance with the requirements specified in Section 724.935.
m)Â Â Â Â Â Â Â A closed-vent system or control device used to comply with
provisions of this Subpart AA must be operated at all times when emissions may
be vented to it.
n)Â Â Â Â Â Â Â Â The owner or operator using a carbon adsorption system to
control air pollutant emissions must document that all carbon removed that is a
hazardous waste and that is removed from the control device is managed in one
of the following manners, regardless of the volatile organic concentration of
the carbon:
1)Â Â Â Â Â Â Â Â It is regenerated or reactivated in a thermal treatment unit
that meets one of the following:
A)Â Â Â Â Â Â Â The owner or operator of the unit has been issued a final
permit under 35 Ill. Adm. Code 702, 703, and 705 that implements the
requirements of Subpart X; or
B)Â Â Â Â Â Â Â The unit is equipped with and operating air emission controls
in accordance with the applicable requirements of Subparts AA and CC or
Subparts AA and CC of 35 Ill. Adm. Code 725; or
C)Â Â Â Â Â Â Â The unit is equipped with and operating air emission controls
in accordance with a national emission standard for hazardous air pollutants
under 40 CFR 61 (National Emission Standards for Hazardous Air Pollutants) or
63 (National Emission Standards for Hazardous Air Pollutants for Source
Categories), each incorporated by reference in 35 Ill. Adm. Code 720.111(b).
2)Â Â Â Â Â Â Â Â It is incinerated in a hazardous waste incinerator for which
the owner or operator has done either of the following:
A)Â Â Â Â Â Â Â The owner or operator has been issued a final permit under 35
Ill. Adm. Code 702, 703, and 705 that implements the requirements of Subpart O;
or
B)Â Â Â Â Â Â Â The owner or operator has certified compliance in accordance
with the interim status requirements of Subpart O of 35 Ill. Adm. Code 725.
3)Â Â Â Â Â Â Â Â It is burned in a boiler or industrial furnace for which the
owner or operator has done either of the following:
A)Â Â Â Â Â Â Â The owner or operator has been issued a final permit under 35
Ill. Adm. Code 702, 703, and 705 that implements the requirements of Subpart H
of 35 Ill. Adm. Code 726; or
B)Â Â Â Â Â Â Â The owner or operator has designed and operates the boiler or
industrial furnace in accordance with the interim status requirements of
Subpart H of 35 Ill. Adm. Code 726.
o)Â Â Â Â Â Â Â Â Any components of a closed-vent system that are designated, as
described in Section 724.935(c)(9), as unsafe to monitor are exempt from the
requirements of subsection (l)(1)(B)(ii) if both of the following conditions
are fulfilled:
1)Â Â Â Â Â Â Â Â The owner or operator of the closed-vent system has determined
that the components of the closed-vent system are unsafe to monitor because
monitoring personnel would be exposed to an immediate danger as a consequence
of complying with subsection (l)(1)(B)(ii); and
2)Â Â Â Â Â Â Â Â The owner or operator of the closed-vent system adheres to a
written plan that requires monitoring the closed-vent system components using
the procedure specified in subsection (l)(1)(B)(ii) as frequently as
practicable during safe-to-monitor times.