35 Ill. Adm. Code 724.963
Test Methods and Procedures
Section 724
Section 724.963Â Test Methods
and Procedures
a)Â Â Â Â Â Â Â Â Each owner or operator subject to the provisions of this
Subpart BB must comply with the test methods and procedures requirements
provided in this Section.
b)Â Â Â Â Â Â Â Â Leak detection monitoring, as required in Sections 724.952
through 724.962, must comply with the following requirements:
1)Â Â Â Â Â Â Â Â Monitoring must comply with Reference Method 21 (Determination
of Volatile Organic Compound Leaks) in appendix A to 40 CFR 60 (Test Methods),
incorporated by reference in 35 Ill. Adm. Code 720.111(b).
2)Â Â Â Â Â Â Â Â The detection instrument must meet the performance criteria of
Reference Method 21.
3)Â Â Â Â Â Â Â Â The instrument must be calibrated before use on each day of
its use by the procedures specified in Reference Method 21.
4)Â Â Â Â Â Â Â Â Calibration gases must be as follows:
A)Â Â Â Â Â Â Â Zero air (less than 10 ppm of hydrocarbon in air); and
B)Â Â Â Â Â Â Â A mixture of methane or n-hexane and air at a concentration of
approximately, but less than 10,000 ppm methane or n-hexane.
5)Â Â Â Â Â Â Â Â The instrument probe must be traversed around all potential
leak interfaces as close to the interface as possible as described in Reference
Method 21.
c)Â Â Â Â Â Â Â Â When equipment is tested for compliance with no detectable
emissions, as required in Sections 724.952(e), 724.953(i), 724.954, and
724.957(f), the test must comply with the following requirements:
1)Â Â Â Â Â Â Â Â The requirements of subsections (b)(1) through (b)(4) apply.
2)Â Â Â Â Â Â Â Â The background level must be determined as set forth in
Reference Method 21.
3)Â Â Â Â Â Â Â Â The instrument probe must be traversed around all potential
leak interfaces as close to the interface as possible as described in Reference
Method 21.
4)Â Â Â Â Â Â Â Â This arithmetic difference between the maximum concentration
indicated by the instrument and the background level is compared with 500 ppm
for determining compliance.
d)Â Â Â Â Â Â Â Â In accordance with the waste analysis plan required by Section
724.113(b), an owner or operator of a facility must determine, for each piece
of equipment, whether the equipment contains or contacts a hazardous waste with
organic concentration that equals or exceeds 10 percent by weight using the
following:
1)Â Â Â Â Â Â Â Â Methods described in ASTM Methods D 2267-88 (Standard Test
Method for Aromatics in Light Naphthas and Aviation Gasolines by Gas
Chromatography), E 168-88 (Standard Practices for General Techniques of
Infrared Quantitative Analysis), E 169-87 (Standard Practices for General
Techniques of Ultraviolet-Visible Quantitative Analysis), or E 260-85 (Standard
Practice for Packed Column Gas Chromatography), each incorporated by reference
in 35 Ill. Adm. Code 720.111(a);
2)Â Â Â Â Â Â Â Â Method 9060A (Total Organic Carbon) of "Test Methods for
Evaluating Solid Waste, Physical/Chemical Methods", USEPA publication
number EPA-530/SW-846, incorporated by reference in 35 Ill. Adm. Code 720.111(a),
for computing total organic concentration of the sample, or analyzed for its
individual constituents; or
3)Â Â Â Â Â Â Â Â Application of the knowledge of the nature of the hazardous
wastestream or the process by which it was produced. Documentation of a waste
determination by knowledge is required. Examples of documentation that must be
used to support a determination under this provision include production process
information documenting that no organic compounds are used, information that
the waste is generated by a process that is identical to a process at the same
or another facility that has previously been demonstrated by direct measurement
to have a total organic content less than 10 percent, or prior speciation analysis
results on the same wastestream where it is also documented that no process
changes have occurred since that analysis that could affect the waste total
organic concentration.
e)Â Â Â Â Â Â Â Â If an owner or operator determines that a piece of equipment
contains or contacts a hazardous waste with organic concentrations at least 10
percent by weight, the determination can be revised only after following the
procedures in subsection (d)(1) or (d)(2).
f)Â Â Â Â Â Â Â Â When an owner or operator and the Agency do not agree on
whether a piece of equipment contains or contacts a hazardous waste with
organic concentrations at least 10 percent by weight, the procedures in
subsection (d)(1) or (d)(2) must be used to resolve the dispute.
g)Â Â Â Â Â Â Â Â Samples used in determining the percent organic content must
be representative of the highest total organic content hazardous waste that is
expected to be contained in or contact the equipment.
h)Â Â Â Â Â Â Â Â To determine if pumps or valves are in light liquid service,
the vapor pressures of constituents must either be obtained from standard
reference texts or be determined by ASTM D 2879-92 (Standard Test Method for
Vapor Pressure-Temperature Relationship and Initial Decomposition Temperature
of Liquids by Isoteniscope), incorporated by reference in 35 Ill. Adm. Code 720.111(a).
i)Â Â Â Â Â Â Â Â Â Performance tests to determine if a control device achieves
95 weight percent organic emission reduction must comply with the procedures of
Section 724.934(c)(1) through (c)(4).