35 Ill. Adm. Code 724.986
Standards: Containers
Section 724
Section 724.986Â Standards:Â
Containers
a)Â Â Â Â Â Â Â Â The provisions of this Section apply to the control of air
pollutant emissions from containers for which Section 724.982(b) references the
use of this Section for such air emission control.
b)Â Â Â Â Â Â Â Â General Requirements
1)Â Â Â Â Â Â Â Â The owner or operator must control air pollutant emissions
from each container subject to this Section in accordance with the following
requirements, as applicable to the container, except when the special
provisions for waste stabilization processes specified in subsection (b)(2)
apply to the container.
A)Â Â Â Â Â Â Â For a container having a design capacity greater than 0.1 m
3
(26 gal) and less than or equal to 0.46 m
3
(120 gal), the owner or
operator must control air pollutant emissions from the container in accordance
with the Container Level 1 standards specified in subsection (c).
B)Â Â Â Â Â Â Â For a container having a design capacity greater than 0.46 m
3
(120 gal) that is not in light material service, the owner or operator must
control air pollutant emissions from the container in accordance with the Container
Level 1 standards specified in subsection (c).
C)Â Â Â Â Â Â Â For a container having a design capacity greater than 0.46 m
3
(120 gal) that is in light material service, the owner or operator must control
air pollutant emissions from the container in accordance with the Container
Level 2 standards specified in subsection (d).
2)Â Â Â Â Â Â Â Â When a container having a design capacity greater than 0.1 m
3
(26 gal) is used for treatment of a hazardous waste by a waste stabilization
process, the owner or operator must control air pollutant emissions from the
container in accordance with the Container Level 3 standards specified in
subsection (e) at those times during the waste stabilization process when the
hazardous waste in the container is exposed to the atmosphere.
c)Â Â Â Â Â Â Â Â Container
Level 1 Standards
1)Â Â Â Â Â Â Â Â A container using Container Level 1 controls is one of the
following:
A)Â Â Â Â Â Â Â A container that meets the applicable USDOT regulations on
packaging hazardous materials for transportation, as specified in subsection
(f).
B)Â Â Â Â Â Â Â A container equipped with a cover and closure devices that form
a continuous barrier over the container openings so that when the cover and
closure devices are secured in the closed position there are no visible holes,
gaps, or other open spaces into the interior of the container. The cover may
be a separate cover installed on the container (e.g., a lid on a drum or a
suitably secured tarp on a roll-off box) or may be an integral part of the
container structural design (e.g., a "portable tank" or bulk cargo
container equipped with a screw-type cap).
C)Â Â Â Â Â Â Â An open-top container in which an organic-vapor suppressing barrier
is placed on or over the hazardous waste in the container so that no hazardous
waste is exposed to the atmosphere. One example of such a barrier is
application of a suitable organic-vapor suppressing foam.
2)Â Â Â Â Â Â Â Â A container used to meet the requirements of subsection
(c)(1)(B) or (c)(1)(C) must be equipped with covers and closure devices, as
applicable to the container, that are composed of suitable materials to
minimize exposure of the hazardous waste to the atmosphere and to maintain the
equipment integrity for as long as it is in service. Factors to be considered
in selecting the materials of construction and designing the cover and closure
devices must include the following:Â the organic vapor permeability; the
effects of contact with the hazardous waste or its vapor managed in the
container; the effects of outdoor exposure of the closure device or cover
material to wind, moisture, and sunlight; and the operating practices for which
the container is intended to be used.
3)Â Â Â Â Â Â Â Â Whenever a hazardous waste is in a container using Container
Level 1 controls, the owner or operator must install all covers and closure
devices for the container, as applicable to the container, and secure and
maintain each closure device in the closed position, except as follows:
A)Â Â Â Â Â Â Â Opening of a closure device or cover is allowed for the purpose
of adding hazardous waste or other material to the container, as follows:
i)Â Â Â Â Â Â Â Â Â If the container is filled to the intended final level in one
continuous operation, the owner or operator must promptly secure the closure
devices in the closed position and install the covers, as applicable to the
container, upon conclusion of the filling operation.
ii)Â Â Â Â Â Â Â Â If discrete quantities or batches of material intermittently
are added to the container over a period of time, the owner or operator must
promptly secure the closure devices in the closed position and install covers,
as applicable to the container, upon either the container being filled to the
intended final level; the completion of a batch loading after which no
additional material will be added to the container within 15 minutes; the
person performing the loading operation leaving the immediate vicinity of the
container; or the shutdown of the process generating the material being added to
the container, whichever condition occurs first.
B)Â Â Â Â Â Â Â Opening of a closure device or cover is allowed for the purpose
of removing hazardous waste from the container, as follows:
i)Â Â Â Â Â Â Â Â Â For the purpose of meeting the requirements of this Section,
an empty container, as defined in 35 Ill. Adm. Code 721.107(b), may be open to
the atmosphere at any time (i.e., covers and closure devices are not required
to be secured in the closed position on an empty container).
ii)Â Â Â Â Â Â Â Â If discrete quantities or batches of material are removed
from the container but the container does not meet the conditions to be an
empty container, as defined in 35 Ill. Adm. Code 721.107(b), the owner or
operator must promptly secure the closure devices in the closed position and
install covers, as applicable to the container, upon the completion of a batch
removal after which no additional material will be removed from the container
within 15 minutes or the person performing the unloading operation leaves the
immediate vicinity of the container, whichever condition occurs first.
C)Â Â Â Â Â Â Â Opening of a closure device or cover is allowed when access
inside the container is needed to perform routine activities other than transfer
of hazardous waste. Examples of such activities include those times when a
worker needs to open a port to measure the depth of or sample the material in
the container, or when a worker needs to open a manhole hatch to access
equipment inside the container. Following completion of the activity, the
owner or operator must promptly secure the closure device in the closed
position or reinstall the cover, as applicable to the container.
D)Â Â Â Â Â Â Â Opening of a spring-loaded pressure-vacuum relief valve,
conservation vent, or similar type of pressure relief device that vents to the
atmosphere is allowed during normal operations for the purpose of maintaining
the internal pressure of the container in accordance with the container design
specifications. The device must be designed to operate with no detectable
organic emissions when the device is secured in the closed position. The
settings at which the device opens must be established so that the device
remains in the closed position whenever the internal pressure of the container
is within the internal pressure operating range determined by the owner or
operator based on container manufacturer recommendations, applicable
regulations, fire protection and prevention codes, standard engineering codes
and practices, or other requirements for the safe handling of flammable,
ignitable, explosive, reactive, or hazardous materials. Examples of normal
operating conditions that may require these devices to open are during those
times when the internal pressure of the container exceeds the internal pressure
operating range for the container as a result of loading operations or diurnal
ambient temperature fluctuations.
E)Â Â Â Â Â Â Â Opening of a safety device, as defined in 35 Ill. Adm. Code
725.981, is allowed at any time conditions require doing so to avoid an unsafe
condition.
4)Â Â Â Â Â Â Â Â The owner or operator of containers using Container Level 1
controls must inspect the containers and their covers and closure devices, as
follows:
A)Â Â Â Â Â Â Â If a hazardous waste already is in the container at the time
the owner or operator first accepts possession of the container at the facility
and the container is not emptied within 24 hours after the container is
accepted at the facility (i.e., it does not meet the conditions for an empty
container, as specified in 35 Ill. Adm. Code 721.107(b)), the owner or operator
must visually inspect the container and its cover and closure devices to check
for visible cracks, holes, gaps, or other open spaces into the interior of the
container when the cover and closure devices are secured in the closed
position. The container visual inspection must be conducted on or before the
date on which the container is accepted at the facility (i.e., the date when
the container becomes subject to the Subpart CC container standards). For the
purposes of this requirement, the date of acceptance is the date of signature
that the facility owner or operator enters on Item 20 of the Uniform Hazardous
Waste Manifest (USEPA Form 8700-22), incorporated by reference in 35 Ill. Adm.
Code 720.111, as required under Section 724.171. If a defect is detected, the
owner or operator must repair the defect in accordance with the requirements of
subsection (c)(4)(C).
B)Â Â Â Â Â Â Â If a container used for managing hazardous waste remains at the
facility for a period of one year or more, the owner or operator must visually
inspect the container and its cover and closure devices initially and
thereafter, at least once every 12 months, to check for visible cracks, holes,
gaps, or other open spaces into the interior of the container when the cover
and closure devices are secured in the closed position. If a defect is
detected, the owner or operator must repair the defect in accordance with the
requirements of subsection (c)(4)(C).
C)Â Â Â Â Â Â Â When a defect is detected for the container, cover, or closure
devices, the owner or operator must make first efforts at repair of the defect
no later than 24 hours after detection and repair must be completed as soon as
possible but no later than five calendar days after detection. If repair of a
defect cannot be completed within five calendar days, then the hazardous waste
must be removed from the container and the container must not be used to manage
hazardous waste until the defect is repaired.
5)Â Â Â Â Â Â Â Â The owner or operator must maintain at the facility a copy of
the procedure used to determine that containers with capacity of 0.46 m
3
(120 gal) or greater that do not meet applicable USDOT Â regulations, as
specified in subsection (f), are not managing hazardous waste in light material
service.
d)Â Â Â Â Â Â Â Â Container
Level 2 Standards
1)Â Â Â Â Â Â Â Â A container using Container Level 2 controls is one of the
following:
A)Â Â Â Â Â Â Â A container that meets the applicable USDOT regulations on
packaging hazardous materials for transportation, as specified in subsection
(f).
B)Â Â Â Â Â Â Â A container that operates with no detectable organic emissions,
as defined in 35 Ill. Adm. Code 725.981, and determined in accordance with the
procedure specified in subsection (g).
C)Â Â Â Â Â Â Â A container that has been demonstrated within the preceding 12
months to be vapor-tight by using Reference Method 27 (Determination of Vapor
Tightness of Gasoline Delivery Tank Using Pressure-Vacuum Test) in appendix A
to 40 CFR 60 (Test Methods), incorporated by reference in 35 Ill. Adm. Code 720.111(b),
in accordance with the procedure specified in subsection (h).
2)Â Â Â Â Â Â Â Â Transfer of hazardous waste in or out of a container using
Container Level 2 controls must be conducted in such a manner as to minimize
exposure of the hazardous waste to the atmosphere, to the extent practical,
considering the physical properties of the hazardous waste and good engineering
and safety practices for handling flammable, ignitable, explosive, reactive, or
other hazardous materials. Examples of container loading procedures that the
USEPA considers to meet the requirements of this subsection (d)(2) include
using any one of the following:Â a submerged-fill pipe or other submerged-fill
method to load liquids into the container; a vapor-balancing system or a vapor-recovery
system to collect and control the vapors displaced from the container during
filling operations; or a fitted opening in the top of a container through which
the hazardous waste is filled and subsequently purging the transfer line before
removing it from the container opening.
3)Â Â Â Â Â Â Â Â Whenever a hazardous waste is in a container using Container
Level 2 controls, the owner or operator must install all covers and closure
devices for the container, and secure and maintain each closure device in the
closed position, except as follows:
A)Â Â Â Â Â Â Â Opening of a closure device or cover is allowed for the purpose
of adding hazardous waste or other material to the container, as follows:
i)Â Â Â Â Â Â Â Â Â If the container is filled to the intended final level in one
continuous operation, the owner or operator must promptly secure the closure
devices in the closed position and install the covers, as applicable to the
container, upon conclusion of the filling operation.
ii)Â Â Â Â Â Â Â Â If discrete quantities or batches of material intermittently
are added to the container over a period of time, the owner or operator must
promptly secure the closure devices in the closed position and install covers,
as applicable to the container, upon whichever of the following conditions
occurs first: the container being filled to the intended final level; the
completion of a batch loading after which no additional material will be added
to the container within 15 minutes; the person performing the loading operation
leaving the immediate vicinity of the container; or the shutdown of the process
generating the material being added to the container.
B)Â Â Â Â Â Â Â Opening of a closure device or cover is allowed for the purpose
of removing hazardous waste from the container, as follows:
i)Â Â Â Â Â Â Â Â Â For the purpose of meeting the requirements of this Section,
an empty container, as defined in 35 Ill. Adm. Code 721.107(b), may be open to
the atmosphere at any time (i.e., covers and closure devices are not required
to be secured in the closed position on an empty container).
ii)Â Â Â Â Â Â Â Â If discrete quantities or batches of material are removed
from the container but the container does not meet the conditions to be an
empty container, as defined in 35 Ill. Adm. Code 721.107(b), the owner or
operator must promptly secure the closure devices in the closed position and
install covers, as applicable to the container, upon the completion of a batch
removal after which no additional material will be removed from the container
within 15 minutes or the person performing the unloading operation leaves the
immediate vicinity of the container, whichever condition occurs first.
C)Â Â Â Â Â Â Â Opening of a closure device or cover is allowed when access
inside the container is needed to perform routine activities other than
transfer of hazardous waste. Examples of such activities include those times when
a worker needs to open a port to measure the depth of or sample the material in
the container, or when a worker needs to open a manhole hatch to access
equipment inside the container. Following completion of the activity, the
owner or operator must promptly secure the closure device in the closed
position or reinstall the cover, as applicable to the container.
D)Â Â Â Â Â Â Â Opening of a spring-loaded, pressure-vacuum relief valve,
conservation vent, or similar type of pressure relief device that vents to the
atmosphere is allowed during normal operations for the purpose of maintaining
the internal pressure of the container in accordance with the container design
specifications. The device must be designed to operate with no detectable
organic emission when the device is secured in the closed position. The
settings at which the device opens must be established so that the device
remains in the closed position whenever the internal pressure of the container
is within the internal pressure operating range determined by the owner or
operator based on container manufacturer recommendations, applicable
regulations, fire protection and prevention codes, standard engineering codes
and practices, or other requirements for the safe handling of flammable,
ignitable, explosive, reactive, or hazardous materials. Examples of normal
operating conditions that may require these devices to open are during those
times when the internal pressure of the container exceeds the internal pressure
operating range for the container as a result of loading operations or diurnal
ambient temperature fluctuations.
E)Â Â Â Â Â Â Â Opening of a safety device, as defined in 35 Ill. Adm. Code
725.981, is allowed at any time conditions require doing so to avoid an unsafe
condition.
4)Â Â Â Â Â Â Â Â The owner or operator of containers using Container Level 2
controls must inspect the containers and their covers and closure devices, as
follows:
A)Â Â Â Â Â Â Â If a hazardous waste already is in the container at the time
the owner or operator first accepts possession of the container at the facility
and the container is not emptied within 24 hours after the container is
accepted at the facility (i.e., it does not meet the conditions for an empty
container as specified in 35 Ill. Adm. Code 721.107(b)), the owner or operator must
visually inspect the container and its cover and closure devices to check for
visible cracks, holes, gaps, or other open spaces into the interior of the
container when the cover and closure devices are secured in the closed
position. The container visual inspection must be conducted on or before the
date on which the container is accepted at the facility (i.e., the date when
the container becomes subject to the Subpart CC container standards). For the
purposes of this requirement, the date of acceptance is the date of signature
that the facility owner or operator enters on Item 20 of the Uniform Hazardous
Waste Manifest (USEPA Form 8700-22), incorporated by reference in 35 Ill. Adm.
Code 722.111, as required under Section 724.171. If a defect is detected, the
owner or operator must repair the defect in accordance with the requirements of
subsection (d)(4)(C).
B)Â Â Â Â Â Â Â If a container used for managing hazardous waste remains at the
facility for a period of one year or more, the owner or operator must visually
inspect the container and its cover and closure devices initially and
thereafter, at least once every 12 months, to check for visible cracks, holes,
gaps, or other open spaces into the interior of the container when the cover
and closure devices are secured in the closed position. If a defect is
detected, the owner or operator must repair the defect in accordance with the
requirements of subsection (d)(4)(C).
C)Â Â Â Â Â Â Â When a defect is detected for the container, cover, or closure
devices, the owner or operator must make first efforts at repair of the defect
no later than 24 hours after detection, and repair must be completed as soon as
possible but no later than five calendar days after detection. If repair of a
defect cannot be completed within five calendar days, then the hazardous waste
must be removed from the container and the container must not be used to manage
hazardous waste until the defect is repaired.
e)Â Â Â Â Â Â Â Â Container
Level 3 Standards
1)Â Â Â Â Â Â Â Â A container using Container Level 3 controls is one of the
following:
A)Â Â Â Â Â Â Â A container that is vented directly through a closed-vent
system to a control device in accordance with the requirements of subsection
(e)(2)(B).
B)Â Â Â Â Â Â Â A container that is vented inside an enclosure that is
exhausted through a closed-vent system to a control device in accordance with
the requirements of subsections (e)(2)(A) and (e)(2)(B).
2)Â Â Â Â Â Â Â Â The owner or operator must meet the following requirements, as
applicable to the type of air emission control equipment selected by the owner
or operator:
A)Â Â Â Â Â Â Â The container enclosure must be designed and operated in
accordance with the criteria for a permanent total enclosure, as specified in
"Procedure T – Criteria for and Verification of a Permanent or Temporary
Total Enclosure" under appendix B to 40 CFR 52.741 (VOM Measurement Techniques
for Capture Efficiency), incorporated by reference in 35 Ill. Adm. Code
720.111(b). The enclosure may have permanent or temporary openings to allow
worker access; passage of containers through the enclosure by conveyor or other
mechanical means; entry of permanent mechanical or electrical equipment; or
direct airflow into the enclosure. The owner or operator must perform the
verification procedure for the enclosure, as specified in Section 5.0 of
"Procedure T – Criteria for and Verification of a Permanent or Temporary
Total Enclosure", initially when the enclosure is first installed and,
thereafter, annually.
B)Â Â Â Â Â Â Â The closed-vent system and control device must be designed and
operated in accordance with the requirements of Section 724.987.
3)Â Â Â Â Â Â Â Â Safety devices, as defined in 35 Ill. Adm. Code 725.981, may
be installed and operated as necessary on any container, enclosure, closed-vent
system, or control device used to comply with the requirements of subsection
(e)(1).
4)Â Â Â Â Â Â Â Â Owners and operators using Container Level 3 controls in
accordance with the provisions of this Subpart CC must inspect and monitor the
closed-vent systems and control devices, as specified in Section 724.987.
5)Â Â Â Â Â Â Â Â Owners and operators that use Container Level 3 controls in
accordance with the provisions of this Subpart CC must prepare and maintain the
records specified in Section 724.989(d).
6)Â Â Â Â Â Â Â Â The transfer of hazardous waste into or out of a container
using Container Level 3 controls must be conducted in such a manner as to
minimize exposure of the hazardous waste to the atmosphere, to the extent
practical considering the physical properties of the hazardous waste and good
engineering and safety practices for handling flammable, ignitable, explosive,
reactive, or other hazardous materials. Examples of container loading
procedures that USEPA considers to meet the requirements of this subsection
(e)(6) include using any one of the following:Â the use of a submerged-fill
pipe or other submerged-fill method to load liquids into the container; the use
of a vapor-balancing system or a vapor-recovery system to collect and control
the vapors displaced from the container during filling operations; or the use
of a fitted opening in the top of a container through which the hazardous waste
is filled and subsequently purging the transfer line before removing it from
the container opening.
f)Â Â Â Â Â Â Â Â For the purpose of compliance with subsection (c)(1)(A) or
(d)(1)(A), containers must be used that meet the applicable USDOT regulations
on packaging hazardous materials for transportation, as follows:
1)Â Â Â Â Â Â Â Â The container meets the applicable requirements specified by
USDOT in 49 CFR 178 (Specifications for Packaging), or 49 CFR 179 (Specifications
for Tank Cars), each incorporated by reference in 35 Ill. Adm. Code 720.111(b).
2)Â Â Â Â Â Â Â Â Hazardous waste is managed in the container in accordance with
the applicable requirements specified by USDOT in subpart B of 49 CFR 107 (Exemptions),
49 CFR 172 (Hazardous Materials Table, Special Provisions, Hazardous Materials
Communications, Emergency Response Information, and Training Requirements), 49
CFR 173 (Shippers – General Requirements for Shipments and Packages), and 49
CFR 180 (Continuing Qualification and Maintenance of Packagings), each
incorporated by reference in 35 Ill. Adm. Code 720.111(b).
3)Â Â Â Â Â Â Â Â For the purpose of complying with this Subpart CC, no
exceptions to the 49 CFR 178 or 179 regulations are allowed, except as provided
for in subsection (f)(4).
4)Â Â Â Â Â Â Â Â For a lab pack that is managed in accordance with the USDOT requirements
of 49 CFR 178 (Specifications for Packagings), for the purpose of complying
with this Subpart CC, an owner or operator may comply with the exceptions for
combination packagings specified by USDOT in 49 CFR 173.12(b) (Exceptions for
Shipments of Waste Materials), incorporated by reference in 35 Ill. Adm. Code 720.111(b).
g)Â Â Â Â Â Â Â Â To determine compliance with the no detectable organic
emissions requirement of subsection (d)(1)(B), the procedure specified in
Section 724.983(d) must be used.
1)Â Â Â Â Â Â Â Â Each potential leak interface (i.e., a location where organic
vapor leakage could occur) on the container, its cover, and associated closure
devices, as applicable to the container, must be checked. Potential leak
interfaces that are associated with containers include, but are not limited to,
the following:Â the interface of the cover rim and the container wall; the
periphery of any opening on the container or container cover and its associated
closure device; and the sealing seat interface on a spring-loaded
pressure-relief valve.
2)Â Â Â Â Â Â Â Â The test must be performed when the container is filled with a
material having a volatile organic concentration representative of the range of
volatile organic concentrations for the hazardous wastes expected to be managed
in this type of container. During the test, the container cover and closure
devices must be secured in the closed position.
h)Â Â Â Â Â Â Â Â Procedure for Determining a Container to be Vapor-Tight Using Reference
Method 27 for the Purpose of Complying with Subsection (d)(1)(C)
1)Â Â Â Â Â Â Â Â The test must be performed in accordance with Reference Method
27.
2)Â Â Â Â Â Â Â Â A pressure measurement device must be used that has a
precision of ± 2.5 mm (0.098 in) water and that is capable of measuring above
the pressure at which the container is to be tested for vapor tightness.
3)Â Â Â Â Â Â Â Â If the test results determined by Reference Method 27 indicate
that the container sustains a pressure change less than or equal to 0.75 kPa
(0.11 psig) within five minutes after it is pressurized to a minimum of 4.5 kPa
(0.65 psig), then the container is determined to be vapor-tight.