35 Ill. Adm. Code 725.113
General Waste Analysis
Section 725
Section 725.113Â General
Waste Analysis
a)Â Â Â Â Â Â Â Â Waste Analysis
1)Â Â Â Â Â Â Â Â Before an owner or operator treats, stores, or disposes of any
hazardous wastes, or non-hazardous wastes if applicable under Section
725.213(d), the owner or operator must obtain a detailed chemical and physical
analysis of a representative sample of the wastes. At a minimum, the analysis
must contain all the information that must be known to treat, store, or dispose
of the waste in accordance with this Part and 35 Ill. Adm. Code 728.
2)Â Â Â Â Â Â Â Â The analysis may include data developed under 35 Ill. Adm.
Code 721 and existing published or documented data on the hazardous waste or on
waste generated from similar processes.
BOARD NOTE:Â
For example, the facility's record of analyses performed on the waste before
the effective date of these regulations or studies conducted on hazardous waste
generated from processes similar to that which generated the waste to be managed
at the facility may be included in the data base required to comply with
subsection (a)(1), except as otherwise specified in 35 Ill. Adm. Code
728.107(b) and (c). The owner or operator of an off-site facility may arrange
for the generator of the hazardous waste to supply part or all of the
information required by subsection (a)(1). If the generator does not supply
the information and the owner or operator chooses to accept a hazardous waste,
the owner or operator is responsible for obtaining the information required to
comply with this Section.
3)Â Â Â Â Â Â Â Â The analysis must be repeated as necessary to ensure that it
is accurate and up to date. At a minimum, the analysis must be repeated as
follows:
A)Â Â Â Â Â Â Â When the owner or operator is notified or has reason to believe
that the process or operation generating the hazardous waste, or non-hazardous
waste if applicable under Section 725.213(d), has changed; and
B)Â Â Â Â Â Â Â For off-site facilities, when the results of the inspection
required in subsection (a)(4) indicate that the hazardous waste received at the
facility does not match the waste designated on the accompanying manifest or
shipping paper.
4)Â Â Â Â Â Â Â Â The owner or operator of an off-site facility must inspect
and, if necessary, analyze each hazardous waste movement received at the
facility to determine whether it matches the identity of the waste specified on
the accompanying manifest or shipping paper.
b)Â Â Â Â Â Â Â Â The owner or operator must develop and follow a written waste
analysis plan that describes the procedures that the owner or operator will
carry out to comply with subsection (a). The owner or operator must keep this
plan at the facility. At a minimum, the plan must specify the following:
1)Â Â Â Â Â Â Â Â The parameters for which each hazardous waste, or
non-hazardous waste if applicable under Section 725.213(d), will be analyzed
and the rationale for the selection of these parameters (i.e., how analysis for
these parameters will provide sufficient information on the waste's properties
to comply with subsection (a)).
2)Â Â Â Â Â Â Â Â The test methods that will be used to test for these
parameters.
3)Â Â Â Â Â Â Â Â The sampling method that will be used to obtain a
representative sample of the waste to be analyzed. A representative sample may
be obtained using either of the following methods:
A)Â Â Â Â Â Â Â One of the sampling methods described in Appendix A to 35 Ill.
Adm. Code 721, or
B)Â Â Â Â Â Â Â An equivalent sampling method.
BOARD NOTE:Â See 35 Ill. Adm. Code 720.120(c) for related discussion.
4)Â Â Â Â Â Â Â Â The frequency with which the initial analysis of the waste
will be reviewed or repeated to ensure that the analysis is accurate and
up-to-date.
5)Â Â Â Â Â Â Â Â For off-site facilities, the waste analyses that hazardous
waste generators have agreed to supply.
6)Â Â Â Â Â Â Â Â Where applicable, the methods that will be used to meet the
additional waste analysis requirements for specific waste management methods,
as specified in Sections 725.300, 725.325, 725.352, 725.373, 725.414, 725.441,
725.475, 725.502, 725.934(d), 725.963(d), and 725.984 and 35 Ill. Adm. Code
728.107.
7)Â Â Â Â Â Â Â Â For surface impoundments exempted from land disposal
restrictions under 35 Ill. Adm. Code 728.104(a), the procedures and schedules
for the following:
A)Â Â Â Â Â Â Â The sampling of impoundment contents;
B)Â Â Â Â Â Â Â The analysis of test data; and
C)Â Â Â Â Â Â Â The annual removal of residues that are not delisted under 35
Ill. Adm. Code 720.122 or that exhibit a characteristic of hazardous waste and
either of the following is true:
i)Â Â Â Â Â Â Â Â Â The waste residues do not meet the applicable treatment standards
of Subpart D of 35 Ill. Adm. Code 728, or
ii)Â Â Â Â Â Â Â Â Where no treatment standards have been established, the waste
residues are prohibited from land disposal under 35 Ill. Adm. Code 728.132 or 728.139.
8)Â Â Â Â Â Â Â Â For an owner or operator seeking an exemption to the air
emission standards of Subpart CC of 35 Ill. Adm. Code 724 in accordance with
Section 725.983:
A)Â Â Â Â Â Â Â If direct measurement is used for the waste determination, the
procedures and schedules for waste sampling and analysis, and the analysis of
test data to verify the exemption.
B)Â Â Â Â Â Â Â If knowledge of the waste is used for the waste determination,
any information prepared by the facility owner or operator, or by the generator
of the waste if the waste is received from off-site, that is used as the basis
for knowledge of the waste.
c)Â Â Â Â Â Â Â Â For off-site facilities, the waste analysis plan required in
subsection (b) must also specify the procedures that will be used to inspect
and, if necessary, analyze each movement of hazardous waste received at the
facility to ensure that it matches the identity of the waste designated on the
accompanying manifest or shipping paper. At a minimum, the plan must describe
the following:
1)Â Â Â Â Â Â Â Â The procedures that will be used to determine the identity of
each movement of waste managed at the facility;
2)Â Â Â Â Â Â Â Â The sampling method that will be used to obtain a
representative sample of the waste to be identified if the identification
method includes sampling; and
3)Â Â Â Â Â Â Â Â The procedures that the owner or operator of an off-site
landfill receiving containerized hazardous waste will use to determine whether
a hazardous waste generator or treater has added a biodegradable sorbent to the
waste in the container.