35 Ill. Adm. Code 725.477
Monitoring and Inspections
Section 725
Section 725.477Â Monitoring
and Inspections
The owner or operator must
conduct, as a minimum, the following monitoring and inspections when thermally
treating hazardous waste:
a)Â Â Â Â Â Â Â Â Existing instruments that relate to temperature and emission
control (if an emission control device is present) must be monitored at least
every 15 minutes. Appropriate corrections to maintain steady state or other
appropriate thermal treatment conditions must be made immediately either
automatically or by the operator. Instruments that relate to temperature and
emission control would normally include those measuring waste feed, auxiliary
fuel feed, treatment process temperature, and relevant process flow and level
controls.
b)Â Â Â Â Â Â Â Â The stack plume (emissions), where present, must be observed
visually at least hourly for normal appearance (color and opacity). The
operator must immediately make any indicated operating corrections necessary to
return any visible emissions to their normal appearance.
c)Â Â Â Â Â Â Â Â The complete thermal treatment process and associated
equipment (pumps, valves, conveyors, pipes, etc.) must be inspected at least
daily for leaks, spills and fugitive emissions, and all emergency shutdown
controls and system alarms must be checked to assure proper operation.