35 Ill. Adm. Code 725.932
Standards: Process Vents
Section 725
Section 725.932Â Standards:Â
Process Vents
a)Â Â Â Â Â Â Â Â The owner or operator of a facility with process vents
associated with distillation, fractionation, thin-film evaporation, solvent
extraction, or air or steam stripping operations managing hazardous wastes with
organic concentrations of at least 10 ppmw must do either of the following:
1)Â Â Â Â Â Â Â Â Reduce total organic emissions from all affected process vents
at the facility below 1.4 kg/h (3 lb/h) and 2.8 Mg/yr (3.1 tons/yr); or
2)Â Â Â Â Â Â Â Â Reduce, by use of a control device, total organic emissions
from all affected process vents at the facility by 95 weight percent.
b)Â Â Â Â Â Â Â Â If the owner or operator installs a closed-vent system and
control device to comply with the provisions of subsection (a), the closed-vent
system and control device must meet the requirements of Section 725.933.
c)Â Â Â Â Â Â Â Â Determinations of vent emissions and emission reductions or
total organic compound concentrations achieved by add-on control devices must
be based on either engineering calculations or performance tests. If
performance tests are used to determine vent emissions, emission reductions, or
total organic compound concentrations achieved by add-on control devices, the
performance tests must conform with the requirements of Section 725.934(c).
d)Â Â Â Â Â Â Â Â When an owner or operator and the Agency do not agree on
determinations of vent emissions or emission reductions or total organic
compound concentrations achieved by add-on control devices based on engineering
calculations, the test methods in Section 725.934(c) must be used to resolve
the disagreement.