35 Ill. Adm. Code 725.954
Standards: Pressure Relief Devices in Gas/Vapor Service
Section 725
Section 725.954Â Standards:Â
Pressure Relief Devices in Gas/Vapor Service
a)Â Â Â Â Â Â Â Â Except during pressure releases, each pressure relief device
in gas/vapor service must be operated with no detectable emissions, as
indicated by an instrument reading of less than 500 ppm above background as
measured by the method specified in Section 725.963(c).
b)Â Â Â Â Â Â Â Â Actions Following Pressure Release
1)Â Â Â Â Â Â Â Â After each pressure release, the pressure relief device must
be returned to a condition of no detectable emissions, as indicated by an
instrument reading of less than 500 ppm above background, as soon as
practicable, but no later than 5 calendar days after each pressure release,
except as provided in Section 725.959.
2)Â Â Â Â Â Â Â Â No later than five calendar days after the pressure release,
the pressure relief device must be monitored to confirm the condition of no
detectable emissions, as indicated by an instrument reading of less than 500
ppm above background, as measured by the method specified in Section
725.963(c).
c)Â Â Â Â Â Â Â Â Any pressure relief device that is equipped with a closed-vent
system capable of capturing and transporting leakage from the pressure relief
device to a control device as described in Section 725.960 is exempt from the
requirements of subsections (a) and (b).