35 Ill. Adm. Code 726.202
Permit Standards for Burners
Section 726
Section 726.202Â Permit Standards
for Burners
a)Â Â Â Â Â Â Â Â Applicability
1)        General. An owner or operator of a BIF that burns hazardous
waste and that does not operate under interim status must comply with the
requirements of this Section and 35 Ill. Adm. Code 703.208 and 703.232, unless
exempt under the small quantity burner exemption of Section 726.208.
2)        Applicability of 35 Ill. Adm. Code 724 Standards. An owner or
operator of a BIF that burns hazardous waste is subject to the following
provisions of 35 Ill. Adm. Code 724, except as provided otherwise by this
Subpart H:
A)Â Â Â Â Â Â Â In Subpart A (General), 35 Ill. Adm. Code 724.104;
B)Â Â Â Â Â Â Â In Subpart B (General facility standards), 35 Ill. Adm. Code 724.111
through 724.118;
C)Â Â Â Â Â Â Â In Subpart C (Preparedness and prevention), 35 Ill. Adm. Code
724.131 through 724.137;
D)Â Â Â Â Â Â Â In Subpart D (Contingency plan and emergency procedures), 35
Ill. Adm. Code 724.151 through 724.156;
E)Â Â Â Â Â Â Â In Subpart E (Manifest system, recordkeeping and reporting),
the applicable provisions of 35 Ill. Adm. Code 724.171 through 724.177;
F)Â Â Â Â Â Â Â Â In Subpart F (Releases from Solid Waste Management Units), 35
Ill. Adm. Code 724.190 and 724.201;
G)Â Â Â Â Â Â Â In Subpart G (Closure and post-closure), 35 Ill. Adm. Code
724.211 through 724.215;
H)Â Â Â Â Â Â Â In Subpart H (Financial requirements), 35 Ill. Adm. Code
724.241, 724.242, 724.243, and 724.247 through 724.251, except that the State
of Illinois and the federal government are exempt from the requirements of Subpart
H of 35 Ill. Adm. Code 724; and
I)Â Â Â Â Â Â Â Â Subpart BB (Air emission standards for equipment leaks),
except 35 Ill. Adm. Code 724.950(a).
b)Â Â Â Â Â Â Â Â Hazardous Waste Analysis
1)Â Â Â Â Â Â Â Â The owner or operator must provide an analysis of the
hazardous waste that quantifies the concentration of any constituent identified
in Appendix H of 35 Ill. Adm. Code 721 that is reasonably expected to be in the
waste. Such constituents must be identified and quantified if present, at
levels detectable by using appropriate analytical methods. The constituents
listed in Appendix H of 35 Ill. Adm. Code 721 that are excluded from this
analysis must be identified and the basis for their exclusion explained. Â This
analysis must provide all information required by this Subpart H and 35 Ill.
Adm. Code 703.208 and 703.232 and must enable the Agency to prescribe such
permit conditions as are necessary to adequately protect human health and the
environment. Such analysis must be included as a portion of the Part B permit
application, or, for facilities operating under the interim status standards of
this Subpart H, as a portion of the trial burn plan that may be submitted
before the Part B application under provisions of 35 Ill. Adm. Code 703.232(g),
as well as any other analysis required by the Agency. The owner or operator of
a BIF not operating under the interim status standards must provide the
information required by 35 Ill. Adm. Code 703.208 and 703.232 in the Part B
application to the greatest extent possible.
2)Â Â Â Â Â Â Â Â Throughout normal operation, the owner or operator must conduct
sampling and analysis as necessary to ensure that the hazardous waste, other
fuels, and industrial furnace feedstocks fired into the BIF are within the
physical and chemical composition limits specified in the permit.
c)        Emissions Standards. An owner or operator must comply with
emissions standards provided by Sections 726.204 through 726.207.
d)Â Â Â Â Â Â Â Â Permits
1)Â Â Â Â Â Â Â Â The owner or operator must burn only hazardous wastes
specified in the facility permit and only under the operating conditions
specified under subsection (e), except in approved trial burns under the
conditions specified in 35 Ill. Adm. Code 703.232.
2)Â Â Â Â Â Â Â Â Hazardous wastes not specified in the permit must not be
burned until operating conditions have been specified under a new permit or
permit modification, as applicable. Operating requirements for new wastes must
be based on either trial burn results or alternative data included with Part B
of a permit application under 35 Ill. Adm. Code 703.208.
3)Â Â Â Â Â Â Â Â BIFs operating under the interim status standards of Section
726.203 are permitted under procedures provided by 35 Ill. Adm. Code
703.232(g).
4)Â Â Â Â Â Â Â Â A permit for a new BIF (those BIFs not operating under the
interim status standards) must establish appropriate conditions for each of the
applicable requirements of this Section, including but not limited to allowable
hazardous waste firing rates and operating conditions necessary to meet the
requirements of subsection (e), in order to comply with the following
standards:
A)Â Â Â Â Â Â Â For the period beginning with initial introduction of hazardous
waste and ending with initiation of the trial burn, and only for the minimum
time required to bring the device to a point of operational readiness to
conduct a trial burn, not to exceed a duration of 720 hours operating time when
burning hazardous waste, the operating requirements must be those most likely
to ensure compliance with the emission standards of Sections 726.204 through
726.207, based on the Agency's engineering judgment. If the applicant is
seeking a waiver from a trial burn to demonstrate conformance with a particular
emission standard, the operating requirements during this initial period of
operation must include those specified by the applicable provisions of Section
726.204, Section 726.205, Section 726.206, or Section 726.207. The Agency must
extend the duration of this period for up to 720 additional hours when good
cause for the extension is demonstrated by the applicant.
B)Â Â Â Â Â Â Â For the duration of the trial burn, the operating requirements
must be sufficient to demonstrate compliance with the emissions standards of
Sections 726.204 through 726.207 and must be in accordance with the approved
trial burn plan;
C)Â Â Â Â Â Â Â For the period immediately following completion of the trial
burn, and only for the minimum period sufficient to allow sample analysis, data
computation, submission of the trial burn results by the applicant, review of
the trial burn results, and modification of the facility permit by the Agency
to reflect the trial burn results, the operating requirements must be those
most likely to ensure compliance with the emission standards Sections 726.204
through 726.207 based on the Agency's engineering judgment.
D)Â Â Â Â Â Â Â For the remaining duration of the permit, the operating
requirements must be those demonstrated in a trial burn or by alternative data
specified in 35 Ill. Adm. Code 703.208, as sufficient to ensure compliance with
the emissions standards of Sections 726.204 through 726.207.
e)Â Â Â Â Â Â Â Â Operating Requirements
1)        General. A BIF burning hazardous waste must be operated in
accordance with the operating requirements specified in the permit at all times
when there is hazardous waste in the unit.
2)Â Â Â Â Â Â Â Â Requirements to Ensure Compliance with the Organic Emissions
Standards
A)       DRE (destruction or removal efficiency) Standard. Operating
conditions must be specified in either of the following ways:Â on a
case-by-case basis for each hazardous waste burned, which conditions must be
demonstrated (in a trial burn or by alternative data, as specified in 35 Ill.
Adm. Code 703.208) to be sufficient to comply with the DRE performance standard
of Section 726.204(a), or as special operating requirements provided by Section
726.204(a)(4) for the waiver of the DRE trial burn. When the DRE trial burn is
not waived under Section 726.204(a)(4), each set of operating requirements must
specify the composition of the hazardous waste (including acceptable variations
in the physical and chemical properties of the hazardous waste that will not
affect compliance with the DRE performance standard) to which the operating
requirements apply. For each such hazardous waste, the permit must specify
acceptable operating limits including, but not limited to, the following
conditions, as appropriate:
i)Â Â Â Â Â Â Â Â Â Feed rate of hazardous waste and other fuels measured and
specified as prescribed in subsection (e)(6);
ii)Â Â Â Â Â Â Â Â Minimum and maximum device production rate when producing
normal product expressed in appropriate units, measured and specified as
prescribed in subsection (e)(6);
iii)Â Â Â Â Â Â Â Appropriate controls of the hazardous waste firing system;
iv)Â Â Â Â Â Â Â Allowable variation in BIF system design or operating
procedures;
v)Â Â Â Â Â Â Â Â Minimum combustion gas temperature measured at a location
indicative of combustion chamber temperature, measured, and specified as
prescribed in subsection (e)(6);
vi)Â Â Â Â Â Â Â An appropriate indicator of combustion gas velocity, measured
and specified as prescribed in subsection (e)(6), unless documentation is
provided under 35 Ill. Adm. Code 703.232 demonstrating adequate combustion gas
residence time; and
vii)Â Â Â Â Â Â Such other operating requirements as are necessary to ensure
that the DRE performance standard of Section 726.204(a) is met.
B)       CO and Hydrocarbon (HC) Standards. The permit must incorporate
a CO limit and, as appropriate, a HC limit as provided by Section 726.204(b),
(c), (d), (e), and (f). The permit limits must be specified as follows:
i)Â Â Â Â Â Â Â Â Â When complying with the CO standard of Section 726.204(b)(1),
the permit limit is 100 ppmv;
ii)Â Â Â Â Â Â Â Â When complying with the alternative CO standard under Section
726.204(c), the permit limit for CO is based on the trial burn and is
established as the average over all valid runs of the highest hourly rolling
average CO level of each run; and, the permit limit for HC is 20 ppmv (as
defined in Section 726.204(c)(1)), except as provided in Section 726.204(f); or
iii)Â Â Â Â Â Â Â When complying with the alternative HC limit for industrial
furnaces under Section 726.204(f), the permit limit for HC and CO is the
baseline level when hazardous waste is not burned as specified by that
subsection.
C)       Start-Up and Shut-Down. During start-up and shut-down of the
BIF, hazardous waste (except waste fed solely as an ingredient under the Tier I
(or adjusted Tier I) feed rate screening limits for metals and
chloride/chlorine, and except low risk waste exempt from the trial burn
requirements under Sections 726.204(a)(5), 726.205, 726.206, and 726.207) must
not be fed into the device, unless the device is operating within the
conditions of operation specified in the permit.
3)Â Â Â Â Â Â Â Â Requirements to Ensure Conformance with the Particulate Matter
(PM) Standard
A)Â Â Â Â Â Â Â Except as provided in subsections (e)(3)(B) and (e)(3)(C), the
permit must specify the following operating requirements to ensure conformance
with the PM standard specified in Section 726.205:
i)Â Â Â Â Â Â Â Â Â Total ash feed rate to the device from hazardous waste, other
fuels, and industrial furnace feedstocks, measured and specified as prescribed
in subsection (e)(6);
ii)Â Â Â Â Â Â Â Â Maximum device production rate when producing normal product
expressed in appropriate units, and measured and specified as prescribed in
subsection (e)(6);
iii)Â Â Â Â Â Â Â Appropriate controls on operation and maintenance of the
hazardous waste firing system and any air pollution control system (APCS);
iv)Â Â Â Â Â Â Â Allowable variation in BIF system design including any APCS or
operating procedures; and
v)Â Â Â Â Â Â Â Â Such other operating requirements as are necessary to ensure
that the PM standard in Section 726.205(a) is met.
B)Â Â Â Â Â Â Â Permit conditions to ensure conformance with the PM standard
must not be provided for facilities exempt from the PM standard under Section
726.205(b);
C)Â Â Â Â Â Â Â For cement kilns and light-weight aggregate kilns, permit
conditions to ensure compliance with the PM standard must not limit the ash
content of hazardous waste or other feed materials.
4)Â Â Â Â Â Â Â Â Requirements to Ensure Conformance with the Metals Emissions
Standard
A)Â Â Â Â Â Â Â For conformance with the Tier I (or adjusted Tier I) metals
feed rate screening limits of Section 726.206(b) or (e), the permit must
specify the following operating requirements:
i)Â Â Â Â Â Â Â Â Â Total feed rate of each metal in hazardous waste, other fuels
and industrial furnace feedstocks measured and specified under provisions of
subsection (e)(6);
ii)Â Â Â Â Â Â Â Â Total feed rate of hazardous waste measured and specified as
prescribed in subsection (e)(6); and
iii)Â Â Â Â Â Â Â A sampling and metals analysis program for the hazardous
waste, other fuels and industrial furnace feedstocks;
B)Â Â Â Â Â Â Â For conformance with the Tier II metals emission rate screening
limits under Section 726.206(c) and the Tier III metals controls under Section
726.206(d), the permit must specify the following operating requirements:
i)Â Â Â Â Â Â Â Â Â Maximum emission rate for each metal specified as the average
emission rate during the trial burn;
ii)Â Â Â Â Â Â Â Â Feed rate of total hazardous waste and pumpable hazardous
waste, each measured and specified as prescribed in subsection (e)(6)(A);
iii)Â Â Â Â Â Â Â Feed rate of each metal in the following feedstreams,
measured and specified as prescribed in subsections (e)(6):Â total feed
streams; total hazardous waste feed; and total pumpable hazardous waste feed;
BOARD NOTE:Â
The Board has combined the text of 40 CFR 266.102(e)(4)(ii)(C)(
1
) and
(e)(4)(ii)(C)(
2
) into this subsection (e)(4)(B)(iii) to comport with
Illinois Administrative Code codification requirements.
iv)Â Â Â Â Â Â Â Total feed rate of chlorine and chloride in total feed streams
measured and specified as prescribed in subsection (e)(6);
v)Â Â Â Â Â Â Â Â Maximum combustion gas temperature measured at a location
indicative of combustion chamber temperature, and measured and specified as
prescribed in subsection (e)(6);
vi)Â Â Â Â Â Â Â Maximum flue gas temperature at the inlet to the PM APCS
measured and specified as prescribed in subsection (e)(6);
vii)Â Â Â Â Â Â Maximum device production rate when producing normal product
expressed in appropriate units and measured and specified as prescribed in
subsection (e)(6);
viii)Â Â Â Â Â Appropriate controls on operation and maintenance of the
hazardous waste firing system and any APCS;
ix)Â Â Â Â Â Â Â Allowable variation in BIF system design including any APCS or
operating procedures; and
x)Â Â Â Â Â Â Â Â Such other operating requirements as are necessary to ensure
that the metals standards under Section 726.206(c) or (d) are met.
C)Â Â Â Â Â Â Â For conformance with an alternative implementation approach
approved by the Agency under Section 726.206(f), the permit must specify the
following operating requirements:
i)Â Â Â Â Â Â Â Â Â Maximum emission rate for each metal specified as the average
emission rate during the trial burn;
ii)Â Â Â Â Â Â Â Â Feed rate of total hazardous waste and pumpable hazardous
waste, each measured and specified as prescribed in subsection (e)(6)(A);
iii)Â Â Â Â Â Â Â Feed rate of each metal in the following feedstreams,
measured and specified as prescribed in subsection (e)(6):Â total hazardous
waste feed; and total pumpable hazardous waste feed;
BOARD NOTE:Â The Board has
combined the text of 40 CFR 266.102(e)(4)(iii)(C)(
1
) and (e)(4)(iii)(C)(
2
)
into this subsection (e)(4)(C)(iii) to comport with Illinois Administrative
Code codification requirements.
iv)Â Â Â Â Â Â Â Total feed rate of chlorine and chloride in total feed streams
measured and specified prescribed in subsection (e)(6);
v)Â Â Â Â Â Â Â Â Maximum combustion gas temperature measured at a location
indicative of combustion chamber temperature, and measured and specified as
prescribed in subsection (e)(6);
vi)Â Â Â Â Â Â Â Maximum flue gas temperature at the inlet to the PM APCS
measured and specified as prescribed in subsection (e)(6);
vii)Â Â Â Â Â Â Maximum device production rate when producing normal product
expressed in appropriate units and measured and specified as prescribed in
subsection (e)(6);
viii)Â Â Â Â Â Appropriate controls on operation and maintenance of the
hazardous waste firing system and any APCS;
ix)Â Â Â Â Â Â Â Allowable variation in BIF system design including any APCS or
operating procedures; and
x)Â Â Â Â Â Â Â Â Such other operating requirements as are necessary to ensure
that the metals standards under Section 726.206(c) or (d) are met.
5)Â Â Â Â Â Â Â Â Requirements to Ensure Conformance with the HCl and Chlorine
Gas Standards
A)Â Â Â Â Â Â Â For conformance with the Tier I total chlorine and chloride
feed rate screening limits of Section 726.207(b)(1), the permit must specify
the following operating requirements:
i)Â Â Â Â Â Â Â Â Â Feed rate of total chlorine and chloride in hazardous waste,
other fuels and industrial furnace feedstocks measured and specified as
prescribed in subsection (e)(6);
ii)Â Â Â Â Â Â Â Â Feed rate of total hazardous waste measured and specified as
prescribed in subsection (e)(6); and
iii)Â Â Â Â Â Â Â A sampling and analysis program for total chlorine and
chloride for the hazardous waste, other fuels and industrial furnace
feedstocks;
B)Â Â Â Â Â Â Â For conformance with the Tier II HCl and chlorine gas emission
rate screening limits under Section 726.207(b)(2) and the Tier III HCl and
chlorine gas controls under Section 726.207(c), the permit must specify the
following operating requirements:
i)Â Â Â Â Â Â Â Â Â Maximum emission rate for HCl and for chlorine gas specified
as the average emission rate during the trial burn;
ii)Â Â Â Â Â Â Â Â Feed rate of total hazardous waste measured and specified as
prescribed in subsection (e)(6);
iii)Â Â Â Â Â Â Â Total feed rate of chlorine and chloride in total feed
streams, measured and specified as prescribed in subsection (e)(6);
iv)Â Â Â Â Â Â Â Maximum device production rate when producing normal product
expressed in appropriate units, measured and specified as prescribed in
subsection (e)(6);
v)Â Â Â Â Â Â Â Â Appropriate controls on operation and maintenance of the
hazardous waste firing system and any APCS;
vi)Â Â Â Â Â Â Â Allowable variation in BIF system design including any APCS or
operating procedures; and
vii)Â Â Â Â Â Â Such other operating requirements as are necessary to ensure
that the HCl and chlorine gas standards under Section 726.207(b)(2) or (c) are
met.
6)Â Â Â Â Â Â Â Â Measuring Parameters and Establishing Limits Based on Trial
Burn Data
A)       General Requirements. As specified in subsections (e)(2)
through (e)(5), each operating parameter must be measured, and permit limits on
the parameter must be established, according to either of the following
procedures:
i)         Instantaneous Limits. A parameter is measured and recorded
on an instantaneous basis (i.e., the value that occurs at any time) and the
permit limit specified as the time-weighted average during all valid runs of
the trial burn; or
ii)        Hourly Rolling Average. The limit for a parameter must be
established and continuously monitored on an hourly rolling average basis, as
defined in Section 726.200(i). The permit limit for the parameter must be
established based on trial burn data as the average over all valid test runs of
the highest hourly rolling average value for each run.
BOARD NOTE:Â The Board has
combined the text of 40 CFR 266.102(e)(6)(i)(B)(
1
) and (e)(6)(i)(B)(
2
)
into this subsection (e)(6)(A)(ii) and moved the text of 40 CFR 266.102(e)(6)(i)(B)(
1
)(
i
)
and (e)(6)(i)(B)(
1
)(
ii
) to appear as definitions of "continuous
monitor" and "hourly rolling average", respectively, in Section
726.200(i) to comport with Illinois Administrative Code codification
requirements.
B)Â Â Â Â Â Â Â Rolling Average Limits for Carcinogenic Metals and Lead. Â Feed
rate limits for the carcinogenic metals (as defined in Section 726.200(i)) and
lead must be established either on an hourly rolling average basis, as
prescribed by subsection (e)(6)(A), or on (up to) a 24 hour rolling average
basis. If the owner or operator elects to use an average period from 2 to 24
hours, the following requirements apply:
i)Â Â Â Â Â Â Â Â Â The feed rate of each metal must be limited at any time to
ten times the feed rate that would be allowed on an hourly rolling average
basis;
ii)Â Â Â Â Â Â Â Â The continuous monitor must meet the specifications of
"continuous monitor", "rolling average for the selected
averaging period", and "one hour block average" as defined in
Section 726.200(i); and
BOARD NOTE:Â The Board has moved
the text of 40 CFR 266.102(e)(6)(ii)(B)(
1
) and (e)(6)(ii)(B)(
2
)
to appear as definitions in Section 726.200(i) to comport with Illinois
Administrative Code codification requirements.
iii)Â Â Â Â Â Â Â The permit limit for the feed rate of each metal must be
established based on trial burn data as the average over all valid test runs of
the highest hourly rolling average feed rate for each run.
C)Â Â Â Â Â Â Â Feed Rate Limits for Metals, Total Chlorine and Chloride, and Ash.Â
Feed rate limits for metals, total chlorine and chloride, and ash are
established and monitored by knowing the concentration of the substance (i.e.,
metals, chloride/chlorine and ash) in each feedstream and the flow rate of the
feedstream. To monitor the feed rate of these substances, the flow rate of
each feedstream must be monitored under the continuous monitoring requirements
of subsections (e)(6)(A) and (e)(6)(B).
D)Â Â Â Â Â Â Â Conducting Trial Burn Testing
i)Â Â Â Â Â Â Â Â Â If compliance with all applicable emissions standards of
Sections 726.204 through 726.207 is not demonstrated simultaneously during a
set of test runs, the operating conditions of additional test runs required to
demonstrate compliance with remaining emissions standards must be as close as
possible to the original operating conditions.
ii)Â Â Â Â Â Â Â Â Prior to obtaining test data for purposes of demonstrating
compliance with the emissions standards of Sections 726.204 through 726.207 or
establishing limits on operating parameters under this Section, the unit must
operate under trial burn conditions for a sufficient period to reach
steady-state operations. However, industrial furnaces that recycle collected
PM back into the furnace and that comply with an alternative implementation
approach for metals under Section 726.206(f) need not reach steady state
conditions with respect to the flow of metals in the system prior to beginning
compliance testing for metals emissions.
iii)Â Â Â Â Â Â Â Trial burn data on the level of an operating parameter for
which a limit must be established in the permit must be obtained during
emissions sampling for the pollutants (i.e., metals, PM, HCl/chlorine gas,
organic compounds) for which the parameter must be established as specified by this
subsection (e).
7)Â Â Â Â Â Â Â Â General Requirements
A)       Fugitive Emissions. Fugitive emissions must be controlled in
one of the following ways:
i)Â Â Â Â Â Â Â Â Â By keeping the combustion zone totally sealed against
fugitive emissions;
ii)Â Â Â Â Â Â Â Â By maintaining the combustion zone pressure lower than
atmospheric pressure; or
iii)Â Â Â Â Â Â Â By an alternative means of control demonstrated (with Part B
of the permit application) to provide fugitive emissions control equivalent to
maintenance of combustion zone pressure lower than atmospheric pressure.
B)       Automatic Waste Feed Cutoff. A BIF must be operated with a
functioning system that automatically cuts off the hazardous waste feed when
operating conditions deviate from those established under this Section. In
addition, the following requirements apply:
i)Â Â Â Â Â Â Â Â Â The permit limit for (the indicator of) minimum combustion
chamber temperature must be maintained while hazardous waste or hazardous waste
residues remain in the combustion chamber;
ii)Â Â Â Â Â Â Â Â Exhaust gases must be ducted to the APCS operated in
accordance with the permit requirements while hazardous waste or hazardous
waste residues remain in the combustion chamber; and
iii)Â Â Â Â Â Â Â Operating parameters for which permit limits are established
must continue to be monitored during the cutoff, and the hazardous waste feed
must not be restarted until the levels of those parameters comply with the
permit limits. For parameters that are monitored on an instantaneous basis,
the Agency must establish a minimum period of time after a waste feed cutoff
during which the parameter must not exceed the permit limit before the hazardous
waste feed is restarted.
C)       Changes. A BIF must cease burning hazardous waste when
combustion properties or feed rates of the hazardous waste, other fuels or
industrial furnace feedstocks, or the BIF design or operating conditions
deviate from the limits as specified in the permit.
8)Â Â Â Â Â Â Â Â Monitoring and Inspections
A)Â Â Â Â Â Â Â The owner or operator must monitor and record the following, at
a minimum, while burning hazardous waste:
i)Â Â Â Â Â Â Â Â Â If specified by the permit, feed rates and composition of
hazardous waste, other fuels, and industrial furnace feedstocks and feed rates
of ash, metals, and total chlorine and chloride;
ii)Â Â Â Â Â Â Â Â If specified by the permit, CO, HCs, and oxygen on a
continuous basis at a common point in the BIF downstream of the combustion zone
and prior to release of stack gases to the atmosphere in accordance with
operating requirements specified in subsection (e)(2)(B). CO, HC, and oxygen
monitors must be installed, operated, and maintained in accordance with methods
specified in Appendix I; and
iii)Â Â Â Â Â Â Â Upon the request of the Agency, sampling and analysis of the
hazardous waste (and other fuels and industrial furnace feedstocks as
appropriate), residues, and exhaust emissions must be conducted to verify that
the operating requirements established in the permit achieve the applicable
standards of Sections 726.204, 726.205, 726.206, and 726.207.
B)Â Â Â Â Â Â Â All monitors must record data in units corresponding to the
permit limit unless otherwise specified in the permit.
C)Â Â Â Â Â Â Â The BIF and associated equipment (pumps, valves, pipes, fuel
storage tanks, etc.) must be subjected to thorough visual inspection when it
contains hazardous waste, at least daily for leaks, spills, fugitive emissions,
and signs of tampering.
D)Â Â Â Â Â Â Â The automatic hazardous waste feed cutoff system and associated
alarms must be tested at least once every seven days when hazardous waste is
burned to verify operability, unless the applicant demonstrates to the Agency
that weekly inspections will unduly restrict or upset operations and that less
frequent inspections will be adequate. At a minimum, operational testing must
be conducted at least once every 30 days.
E)Â Â Â Â Â Â Â These monitoring and inspection data must be recorded and the
records must be placed in the operating record required by 35 Ill. Adm. Code
724.173.
9)        Direct Transfer to the Burner. If hazardous waste is directly
transferred from a transport vehicle to a BIF without the use of a storage
unit, the owner and operator must comply with Section 726.211.
10)        Recordkeeping. The owner or operator must maintain in the
operating record of the facility all information and data required by this
Section for five years.
11)        Closure. At closure, the owner or operator must remove all
hazardous waste and hazardous waste residues (including, but not limited to,
ash, scrubber waters, and scrubber sludges) from the BIF.