35 Ill. Adm. Code 726.207
Standards to Control HCl and Chlorine Gas Emissions
Section 726
Section 726.207Â Standards to
Control HCl and Chlorine Gas Emissions
a)        General. The owner or operator must comply with the HCl and
chlorine gas controls provided by subsection (b), (c), or (e).
b)Â Â Â Â Â Â Â Â Screening Limits
1)        Tier I Feed Rate Screening Limits. Feed rate screening limits
are specified for total chlorine in Appendix B as a function of TESH and
terrain and land use in the vicinity of the facility. The feed rate of total
chlorine and chloride, both organic and inorganic, in all feed streams,
including hazardous waste, fuels, and industrial furnace feed stocks must not
exceed the levels specified.
2)        Tier II Emission Rate Screening Limits. Emission rate
screening limits for HCl and chlorine gas are specified in Appendix C as a function
of TESH and terrain and land use in the vicinity of the facility. The stack
emission rates of HCl and chlorine gas must not exceed the levels specified.
3)        Definitions and Limitations. The definitions and limitations
provided by Sections 726.200(i) and 726.206(b) for the following terms also
apply to the screening limits provided by this subsection:Â TESH, good
engineering practice stack height, terrain type, land use, and criteria for
facilities not eligible to use the screening limits.
4)        Multiple Stacks. Owners and operators of facilities with more
than one on-site stack from a BIF, incinerator or other thermal treatment unit
subject to controls on HCl or chlorine gas emissions under a RCRA permit or
interim status controls must comply with the Tier I and Tier II screening
limits for those stacks assuming all hazardous waste is fed into the device
with the worst-case stack based on dispersion characteristics.
A)Â Â Â Â Â Â Â The worst-case stack is determined by procedures provided in
Section 726.206(b)(6).
B)Â Â Â Â Â Â Â Under Tier I, the total feed rate of chlorine and chloride to
all subject devices must not exceed the screening limit for the worst-case
stack.
C)Â Â Â Â Â Â Â Under Tier II, the total emissions of HCl and chlorine gas from
all subject stacks must not exceed the screening limit for the worst-case
stack.
c)Â Â Â Â Â Â Â Â Tier III Site-Specific Risk Assessments
1)        General. Conformance with the Tier III controls must be
demonstrated by emissions testing to determine the emission rate for HCl and
chlorine gas, air dispersion modeling to predict the maximum annual average
off-site ground level concentration for each compound, and a demonstration that
acceptable ambient levels are not exceeded.
2)        Acceptable Ambient Levels. Appendix D lists the RACs for HCl
(7 μg/m
3
) and chlorine gas (0.4 μg/m
3
).
3)        Multiple Stacks. Owners and operators of facilities with more
than one on-site stack from a BIF, incinerator, or other thermal treatment unit
subject to controls on HCl or chlorine gas emissions under a RCRA permit or
interim status controls must conduct emissions testing and dispersion modeling
to demonstrate that the aggregate emissions from all such on-site stacks do not
result in an exceedance of the acceptable ambient levels for HCl and chlorine
gas.
d)        Averaging Periods. The HCl and chlorine gas controls are
implemented by limiting the feed rate of total chlorine and chloride in all
feedstreams, including hazardous waste, fuels, and industrial furnace feed
stocks. Under Tier I, the feed rate of total chlorine and chloride is limited
to the Tier I Screening Limits. Under Tier II and Tier III, the feed rate of
total chlorine and chloride is limited to the feed rates during the trial burn
(for new facilities or an interim status facility applying for a permit) or the
compliance test (for interim status facilities). The feed rate limits are
based on either of the following:
1)Â Â Â Â Â Â Â Â An hourly rolling average, as defined in Sections 726.200(i) and
726.202(e)(6); or
2)Â Â Â Â Â Â Â Â An instantaneous basis not to be exceeded at any time.
e)        Adjusted Tier I Feed Rate Screening Limits. The owner or
operator may adjust the feed rate screening limit provided by Appendix B to
account for site-specific dispersion modeling. Under this approach, the
adjusted feed rate screening limit is determined by back-calculating from the
acceptable ambient level for chlorine gas provided by Appendix D using
dispersion modeling to determine the maximum allowable emission rate. This
emission rate becomes the adjusted Tier I feed rate screening limit.
f)        Emissions Testing. Emissions testing for HCl and chlorine gas
(Cl
2
) must be conducted using the procedures described in Method
0050 or 0051, in "Test Methods for Evaluating Solid Waste,
Physical/Chemical Methods", USEPA publication number EPA-530/SW-846,
incorporated by reference in 35 Ill. Adm. Code 720.111(a).
g)        Dispersion Modeling. Dispersion modeling must be conducted
according to the provisions of Section 726.206(h).
h)        Enforcement. For the purposes of permit enforcement,
compliance with the operating requirements specified in the permit (under
Section 726.202) will be regarded as compliance with this Section. However,
evidence that compliance with those permit conditions is insufficient to ensure
compliance with the requirements of this Section is "information"
justifying modification or revocation and re-issuance of a permit under 35 Ill.
Adm. Code 703.270 through 703.273.