35 Ill. Adm. Code 730.183
Minimum Criteria for Siting
Section 730.183 Minimum Criteria for Siting
a) The
owner or operator of a Class VI injection well must sufficiently demonstrate to
support an Agency determination that the wells will be sited in areas with a
suitable geologic system. The owner or operator must sufficiently demonstrate
that the geologic system comprises both of the following elements:
1) An
injection zone of sufficient areal extent, thickness, porosity, and
permeability to receive the total anticipated volume of the carbon dioxide stream;
and
2) Confining
zones free of transmissive faults or fractures and of sufficient areal extent
and integrity to contain the injected carbon dioxide stream and displaced
formation fluids and allow injection at proposed maximum pressures and volumes
without initiating or propagating fractures in the confining zones.
b) The
Agency may require the owner or operator of a Class VI injection well to
identify and characterize additional zones that will impede vertical fluid
movement; that are free of faults and fractures which may interfere with
containment; that allow for pressure dissipation; and that provide additional
opportunities for monitoring, mitigation, and remediation.
BOARD NOTE: This Section
corresponds with 40 CFR 146.83 (2011).