35 Ill. Adm. Code 730.188
Injection Well Operating Requirements
Section 730.188 Injection Well Operating Requirements
a) Except
during injection well stimulation, the owner or operator must ensure that
injection pressure does not exceed 90 percent of the fracture pressure of the
injection zones, so as to ensure that the injection does not initiate new
fractures or propagate existing fractures in the injection zones. In no case
may injection pressure initiate fractures in the confining zones or cause the
movement of injection or formation fluids that endangers a USDW. Pursuant to
the requirements of Section 730.182(a)(9), all stimulation programs must be
approved by the Agency as part of the permit application and incorporated into
the permit.
b) Injection
between the outermost casing that protects any USDW and the well bore is
prohibited.
c) The
owner or operator must fill the annulus between the tubing and the long-string
casing with a non-corrosive fluid approved by the Agency. The owner or
operator must maintain on the annulus a pressure that exceeds the operating
injection pressure, unless the Agency determines that such a requirement might
harm the integrity of the well or endanger any USDW.
d) Other
than during periods of well workover (maintenance) approved by the Agency in
which the sealed tubing-casing annulus is disassembled for maintenance or
corrective procedures, the owner or operator must maintain mechanical integrity
of the injection well at all times.
e) The
owner or operator must install and use the equipment indicated in subsection
(e)(1) and the appropriate of subsection (e)(2) or (e)(3):
1) Continuous
recording devices that monitor each of the following parameters:
A) The carbon dioxide
injection pressure;
B) The
rate, volume or mass, and temperature of the carbon dioxide stream;
C) The
pressure on the annulus between the tubing and the long-string casing; and
D) The annulus fluid
volume.
2) For
onshore wells, alarms and automatic surface shut-off systems or, at the
discretion of the Agency, down-hole shut-off systems (e.g., automatic shut-off
valves, check valves, etc.) or other mechanical devices that provide equivalent
protection.
3) For
wells located offshore but within State territorial waters, alarms and
automatic down-hole shut-off systems designed to alert the operator and shut-in
the well when operating parameters, such as annulus pressure, injection rate, or
other parameters, diverge beyond permitted ranges or gradients specified in the
permit.
f) If a
shutdown is triggered (down-hole or at the surface), or if a loss of mechanical
integrity is discovered, the owner or operator must immediately investigate and
identify the cause of the shutoff as expeditiously as possible. If, upon
investigation, or if monitoring required under subsection (e) otherwise indicates
that the well may be lacking mechanical integrity, the well appears to be
lacking mechanical integrity, the owner or operator must undertake each of the
following actions:
1) The owner or operator
must immediately cease injection;
2) The
owner or operator must take all steps reasonably necessary to determine whether
there may have been a release of the injected carbon dioxide stream or
formation fluids into any unauthorized zone;
3) The
owner or operator must notify the Agency of the event within 24 hours;
4) The
owner or operator must restore and demonstrate the mechanical integrity of the
well to the satisfaction of the Agency prior to resuming injection; and
5) The
owner or operator must notify the Agency when injection can be expected to
resume.
BOARD NOTE: This Section
corresponds with 40 CFR 146.88 (2017).