35 Ill. Adm. Code 734.315
Stage 1 Site Investigation
Section 734.315 Stage 1 Site Investigation
The Stage 1 site investigation must be designed to gather
initial information regarding the extent of on-site soil and groundwater
contamination that, as a result of the release, exceeds the most stringent Tier
1 remediation objectives of 35 Ill. Adm. Code 742 for the applicable indicator
contaminants.
a) The Stage 1 site
investigation must consist of the following:
1) Soil
investigation.
A) Up to
four borings must be drilled around each independent UST field where one or
more UST excavation samples collected pursuant to 734.210(h), excluding
backfill samples, exceed the most stringent Tier 1 remediation objectives of 35
Ill. Adm. Code 742 for the applicable indicator contaminants. One additional
boring must be drilled as close as practicable to each UST field if a
groundwater investigation is not required under subsection (a)(2) of this
Section. The borings must be advanced through the entire vertical extent of
contamination, based upon field observations and field screening for organic
vapors, provided that borings must be drilled below the groundwater table only
if site-specific conditions warrant.
B) Up to
two borings must be drilled around each UST piping run where one or more piping
run samples collected pursuant to Section 734.210(h) exceed the most stringent
Tier 1 remediation objectives of 35 Ill. Adm. Code 742 for the applicable
indicator contaminants. One additional boring must be drilled as close as
practicable to each UST piping run if a groundwater investigation is not
required under subsection (a)(2) of this Section. The borings must be advanced
through the entire vertical extent of contamination, based upon field
observations and field screening for organic vapors, provided that borings must
be drilled below the groundwater table only if site-specific conditions
warrant.
C) One
soil sample must be collected from each five-foot interval of each boring
drilled pursuant to subsections (a)(1)(A) and (B) of this Section. Each sample
must be collected from the location within the five-foot interval that is the
most contaminated as a result of the release. If an area of contamination
cannot be identified within a five-foot interval, the sample must be collected
from the center of the five-foot interval. All samples must be analyzed for
the applicable indicator contaminants.
2) Groundwater
investigation.
A) A
groundwater investigation is required under the following circumstances:
i) There
is evidence that groundwater wells have been impacted by the release above the
most stringent Tier 1 remediation objectives of 35 Ill. Adm. Code 742 for the
applicable indicator contaminants;
ii) Free
product that may impact groundwater is found to need recovery in compliance
with Section 734.215 of this Part; or
iii) There
is evidence that contaminated soils may be or may have been in contact with
groundwater, except that, if the owner or operator pumps the excavation or tank
cavity dry, properly disposes of all contaminated water, and demonstrates to
the Agency that no recharge is evident during the 24 hours following pumping,
the owner or operator does not have to complete a groundwater investigation,
unless the Agency's review reveals that further groundwater investigation is
necessary.
B) If a
groundwater investigation is required, the owner or operator must install five
groundwater monitoring wells. One monitoring well must be installed in the
location where groundwater contamination is most likely to be present. The
four remaining wells must be installed at the property boundary line or 200
feet from the UST system, whichever is less, in opposite directions from each
other. The wells must be installed in locations where they are most likely to
detect groundwater contamination resulting from the release and provide
information regarding the groundwater gradient and direction of flow.
C) One
soil sample must be collected from each five-foot interval of each monitoring
well installation boring drilled pursuant to subsection (a)(2)(B) of this
Section. Each sample must be collected from the location within the five-foot
interval that is the most contaminated as a result of the release. If an area
of contamination cannot be identified within a five-foot interval, the sample
must be collected from the center of the five-foot interval. All soil samples
exhibiting signs of contamination must be analyzed for the applicable indicator
contaminants. For borings that do not exhibit any signs of soil contamination,
samples from the following intervals must be analyzed for the applicable
indicator contaminants, provided that the samples must not be analyzed if other
soil sampling conducted to date indicates that soil contamination does not
extend to the location of the monitoring well installation boring:
i) The
five-foot intervals intersecting the elevations of soil samples collected
pursuant to Section 734.210(h), excluding backfill samples, that exceed the
most stringent Tier 1 remediation objectives of 35 Ill. Adm. Code 742 for the
applicable indicator contaminants.
ii) The
five-foot interval immediately above each five-foot interval identified in
subsection (a)(2)(C)(i) of this Section; and
iii) The
five-foot interval immediately below each five-foot interval identified in
subsection (a)(2)(C)(i) of this Section.
D) Following
the installation of the groundwater monitoring wells, groundwater samples must
be collected from each well and analyzed for the applicable indicator
contaminants.
E) As a
part of the groundwater investigation an in-situ hydraulic conductivity test
must be performed in the first fully saturated layer below the water table. If
multiple water bearing units are encountered, an in-situ hydraulic conductivity
test must be performed on each such unit.
i) Wells
used for hydraulic conductivity testing must be constructed in a manner that
ensures the most accurate results.
ii) The screen must be
contained within the saturated zone.
3) An
initial water supply well survey in accordance with Section 734.445(a) of this
Part.
b) The
Stage 1 site investigation plan must consist of a certification signed by the
owner or operator, and by a Licensed Professional Engineer or Licensed
Professional Geologist, that the Stage 1 site investigation will be conducted
in accordance with this Section.
c) If
none of the samples collected as part of the Stage 1 site investigation exceed
the most stringent Tier 1 remediation objectives of 35 Ill. Adm. Code 742 for
the applicable indicator contaminants, the owner or operator must cease site
investigation and proceed with the submission of a site investigation
completion report in accordance with Section 734.330 of this Part. If one or
more of the samples collected as part of the Stage 1 site investigation exceed
the most stringent Tier 1 remediation objectives of 35 Ill. Adm. Code 742 for
the applicable indicator contaminants, within 30 days after completing the
Stage 1 site investigation the owner or operator must submit to the Agency for
review a Stage 2 site investigation plan in accordance with Section 734.320 of
this Part.