35 Ill. Adm. Code 738.124
Termination of Approved Petition
Section 738
Section 738.124 Termination
of Approved Petition
a) Termination Through an Enforcement Action
1) An enforcement action against an owner or operator having an adjusted
standard and limitation on Agency petitions for reconsideration of an adjusted standard:
A) Any person may file an enforcement action against an owner or
operator of an underground injection well pursuant to Section 33 of the
Environmental Protection Act for any violation of the Act or Board rules,
notwithstanding the existence of any adjusted standard.
B) The Agency may petition the Board for reconsideration of any
adjusted standard at any time during the effectiveness of that adjusted
standard, the limitation periods of 35 Ill. Adm. Code 101.520 and 101.904
notwithstanding.
2) In any action under subsection (a)(1), if the Board finds a
violation of the Act or Board regulations, the Board may terminate any adjusted
standard granted under Section 738.120 for any of the following causes:
A) Noncompliance by the owner or operator with any condition of
the adjusted standard;
B) The owner or operator's failure in the petition or during the
review and approval to disclose fully all relevant facts, or the petitioner's
misrepresentation of any relevant facts at any time; or
C) A determination that new information shows that the basis for
approval of the petition is no longer valid.
b) In any action under subsection (a)(1), the Board will
terminate an adjusted standard granted under Section 738.120 for the following causes:
1) The petitioner's willful withholding during the review and
approval of the petition of facts directly and materially relevant to the
Board's decision on the petition;
2) A determination that there has been migration from the
injection zone or the well that is not in accordance with the terms of the
adjusted standard, except that the Board, may at its discretion decide not to
terminate where both of the following conditions are fulfilled:
A) The migration resulted from a mechanical failure of the well that
can be promptly corrected through a repair to the injection well itself or from
an undetected well or conduit that can be plugged promptly; and
B) The requirements of 35 Ill. Adm. Code 730.167 are satisfied.
BOARD NOTE: Derived from 40 CFR 148.24 (2017).