35 Ill. Adm. Code 742.610
Chemical and Site Properties
Section 742
Section 742.610Â Chemical and
Site Properties
a)Â Â Â Â Â Â Â Â Physical and Chemical Properties of Contaminants
Tier 2 evaluations require information on the physical and
chemical properties of the contaminants of concern. The physical and chemical
properties used in a Tier 2 evaluation are contained in Appendix C, Table E. If
the site has contaminants not included in this table, a person may request the
Agency to provide the applicable physical and chemical input values or may
propose input values under Subpart I. If a person proposes to apply values
other than those in Appendix C, Table E, or those provided by the Agency, the
evaluation shall be considered under Tier 3.
b)Â Â Â Â Â Â Â Â Soil and Groundwater Parameters
1)Â Â Â Â Â Â Â Â A Tier 2 evaluation requires examination of soil and
groundwater parameters. The parameters that may be varied, and the conditions
under which these parameters are determined as part of Tier 2, are summarized
in Appendix C, Tables B, D, and M. If a person proposes to vary site-specific
parameters outside of the framework of these tables, the evaluation shall be
considered under Tier 3.
2)Â Â Â Â Â Â Â Â To determine site-specific physical soil parameters, a minimum
of one boring per 0.5 acre of contamination shall be collected. This boring
must be deep enough to allow the collection of the required field
measurements. The site-specific physical soil parameters must be determined
from the portion of the boring representing the stratigraphic units being
evaluated. For example, if evaluating the soil component of the groundwater
ingestion exposure route, two samples from the boring will be required:
A)Â Â Â Â Â Â Â A sample of the predominant soil type for the vadose zone; and
B)Â Â Â Â Â Â Â A sample of the predominant soil type for the saturated zone.
3)Â Â Â Â Â Â Â Â A site-specific SSL dilution factor (used in developing soil
remediation objectives based upon the protection of groundwater) may be determined
by substituting site information in Equation S22 in Appendix C, Table A. To
make this demonstration, a minimum of three monitoring wells shall be used to
determine the hydraulic gradient. As an alternative, the default dilution
factor value listed in Appendix C, Table B may be used. If monitoring wells
are used to determine the hydraulic gradient, the soil taken from the borings
shall be visually inspected to ensure there are no significant differences in
the stratigraphy. If there are similar soil types in the field, one boring
shall be used to determine the site-specific physical soil parameters. If
there are significant differences, all of the borings shall be evaluated before
determining the site-specific physical soil parameters for the site.
4)Â Â Â Â Â Â Â Â Not all of the parameters identified in Appendix C, Tables B,
D, and M need to be determined on a site-specific basis. A person may choose
to collect partial site-specific information and use default values as listed
in Appendix C, Tables B, D, and M for the rest of the parameters.