35 Ill. Adm. Code 742.APPENDIX C

C Tier 2 Tables

Last amended: 2013Year: 2026Length: 392 wordsOfficial source
Section 742.APPENDIX C   Tier 2 Tables Section 742.TABLE L   J&E Equations a Indoor air remediation objectives (mg/m 3 ) For carcinogenic contaminants J&E1 For noncarcinogenic contaminants J&E2 To convert mg/m 3 from parts per million volume Note:  24.45 equals the molar volume of air in liters at normal temperature (25°C) and pressure (760 mmHg). J&E3 Soil gas remediation objective (mg/m 3 ) J&E4 Soil Vapor Saturation Limit (mg/m 3 -air) J&E5 Groundwater remediation objectives J&E6 Attenuation factor Attenuation factor when the mode of contaminant transport is both diffusion and advection Q soil = 83.33 cm 3 /sec J&E7 Attenuation factor when the mode of contaminant transport is diffusion only Q soil = 0 cm 3 /sec J&E8 Total overall effective diffusion coefficient for vapor transport in porous media for multiple soil layers (cm 2 /s) J&E9a In Equation J&E9a, the following condition must be satisfied: J&E9b Source to building separation (cm) J&E10 Effective diffusion coefficient for each soil layer (cm 2 /s) J&E11 Surface area of enclosed space at or below grade (cm 2 ) For a building with a full concrete slab-on-grade J&E12a Surface area of enclosed space at or below grade (cm 2 ) For a building with a full concrete basement floor and walls J&E12b Building ventilation rate (cm 3 /s) J&E13 Area of total cracks (cm 2 ) J&E14 Effective diffusion coefficient through the cracks (cm 2 /s) J&E15 Total porosity J&E16 Water-filled soil porosity J&E17 Air-filled soil porosity J&E18 a This table contains equations based on the assumption that the existing or potential building has a full concrete slab-on-grade or a full concrete basement floor and walls.  This table applies only when the existing or potential building has a full concrete slab-on-grade or a full concrete basement floor and walls.  Institutional controls under Subpart J are required to develop remediation objectives pursuant to this table.  This table does not apply when the existing or potential building has neither a full concrete slab-on-grade nor a full concrete basement floor and walls, such as a building with an earthen crawl space, an earthen floor, a stone foundation, a partial concrete floor, or a sump.  In such cases, site evaluators have the option of excluding the indoor inhalation exposure route under Section 742.312, meeting the building control technology requirements under Subpart L, or proposing an alternative approach under Tier 3.
35 Ill. Adm. Code 742.APPENDIX C: C Tier 2 Tables | Justis AI