35 Ill. Adm. Code 742.APPENDIX C
C Tier 2 Tables
Section 742.APPENDIX C Â Â Tier 2 Tables
Section 742.TABLE L Â Â J&E Equations
a
Indoor
air remediation objectives (mg/m
3
)
For
carcinogenic contaminants
J&E1
For
noncarcinogenic contaminants
J&E2
To
convert mg/m
3
from parts per million volume
Note:Â 24.45 equals the
molar volume of air in liters at normal temperature (25°C) and pressure (760
mmHg).
J&E3
Soil
gas remediation objective (mg/m
3
)
J&E4
Soil
Vapor Saturation Limit
(mg/m
3
-air)
J&E5
Groundwater
remediation objectives
J&E6
Attenuation
factor
Attenuation factor when the
mode of contaminant transport is both diffusion and advection
Q
soil
=
83.33 cm
3
/sec
J&E7
Attenuation factor when the
mode of contaminant transport is diffusion only
Q
soil
=
0 cm
3
/sec
J&E8
Total overall effective diffusion coefficient for vapor transport in
porous media for multiple soil layers (cm
2
/s)
J&E9a
In Equation J&E9a, the
following condition must be satisfied:
J&E9b
Source to building
separation (cm)
J&E10
Effective diffusion
coefficient for each soil layer (cm
2
/s)
J&E11
Surface area of enclosed
space at or below grade (cm
2
)
For a building with a full
concrete slab-on-grade
J&E12a
Surface area of enclosed
space at or below grade (cm
2
)
For a building with a full
concrete basement floor and walls
J&E12b
Building ventilation rate
(cm
3
/s)
J&E13
Area of total cracks (cm
2
)
J&E14
Effective diffusion
coefficient through the cracks (cm
2
/s)
J&E15
Total porosity
J&E16
Water-filled soil porosity
J&E17
Air-filled soil porosity
J&E18
a
This
table contains equations based on the assumption that the existing or potential
building has a full concrete slab-on-grade or a full concrete basement floor
and walls. This table applies only when the existing or potential building has
a full concrete slab-on-grade or a full concrete basement floor and walls.Â
Institutional controls under Subpart J are required to develop remediation
objectives pursuant to this table. This table does not apply when the existing
or potential building has neither a full concrete slab-on-grade nor a full
concrete basement floor and walls, such as a building with an earthen crawl
space, an earthen floor, a stone foundation, a partial concrete floor, or a
sump. In such cases, site evaluators have the option of excluding the indoor
inhalation exposure route under Section 742.312, meeting the building control
technology requirements under Subpart L, or proposing an alternative approach
under Tier 3.