35 Ill. Adm. Code 750.482
Engineering Methods for On-Site Actions - Groundwater Controls
Section 750
Section 750.482 Engineering
Methods for On-Site Actions − Groundwater Controls
Groundwater pollution is a
particularly serious problem because, once an aquifer has been contaminated,
the resource cannot usually be cleaned without the expenditure of great time,
effort and resources. Techniques that can be applied to the problem with varying
degrees of success are as follows:
a) Impermeable barriers:
1) Slurry walls;
2) Grout curtains;
3) Sheet pilings.
b) Permeable treatment beds;
c) Groundwater pumping:
1) Water table adjustment;
2) Plume containment.
d) Leachate control
−
Leachate control systems are
applicable to control of surface seeps and seepage of leachate to groundwater.
Leachate collection systems consist of a series of drains which intercept the
leachate and channel it to a sump, wetwell, treatment system, or appropriate
surface discharge point. Technologies applicable to leachate control include
the following:
1) Subsurface drains;
2) Drainage ditches;
3) Liners.