35 Ill. Adm. Code 808.APPENDIX B
B Toxicity Hazard
Section 808.APPENDIX BÂ Â
Toxicity Hazard
This Appendix describes the
method by which a generator of special waste or the waste source shall
determine the toxic score for a waste.
a)Â Â Â Â Â Â Â Â The wastestream equivalent toxic concentration (Ceq) is
calculated as follows:
Ceq = A * SUM(Ci / Bi * Ti)
where:
1)Â Â Â Â Â Â Â Â SUM means the sum of the results of the calculation in
parentheses for each component of the wastestream;
2)Â Â Â Â Â Â Â Â Ci is the concentration of component i as a percent of the
waste by weight;
3)Â Â Â Â Â Â Â Â Ti is a measure of the toxicity of component i, as provided in
subsection (h);
4)Â Â Â Â Â Â Â Â A is a constant equal to 300; and
BOARD NOTE:Â A is a constant used to allow the entry of
percent values for Ci, and to adjust the results so that a reference material,
100 percent copper sulfate, with an oral toxicity of 300 mg/kg, achieves an
equivalent toxic concentration of 100.
5)Â Â Â Â Â Â Â Â Bi is a conversion factor used to convert the toxicity of
component i (Ti) to an equivalent oral toxicity. Bi is determined from
subsection (i).
b)Â Â Â Â Â Â Â Â The toxic amount (M) is calculated as follows:
M = S * Ceq
where:
1)Â Â Â Â Â Â Â Â S is the maximum size of a wastestream shipment in kg/month
(Such maximum size shall be specified as a condition of the wastestream
classification.); and
2)Â Â Â Â Â Â Â Â Ceq is the equivalent concentration from subsection (a).
c)Â Â Â Â Â Â Â Â The toxic score is calculated as follows:
1)Â Â Â Â Â Â Â Â If the toxic amount (M) is less than 100, the toxic score is
0.
2)Â Â Â Â Â Â Â Â If the toxic amount is greater than or equal to 100 and less
than 1000, the toxic score is 1.
3)Â Â Â Â Â Â Â Â If the toxic amount is greater than or equal to 1000 and less
than 10,000, the toxic score is 2.
4)Â Â Â Â Â Â Â Â If the toxic amount is greater than or equal to 10,000, the
toxic score is 3.
BOARD NOTE:Â 100 kg/month of the reference material, 100
percent copper sulfate, has a "toxic amount" of 10,000, defining the
boderline between a "toxic score" of 2 or 3 for a small quantity
generator.
d)Â Â Â Â Â Â Â Â The toxic score shall be used as follows:
1)Â Â Â Â Â Â Â Â If the toxic score is 0 or 3, the toxic score shall be used
for the purposes of Section 808.245 without adjustment.
2)Â Â Â Â Â Â Â Â If the toxic score is 1 or 2, the toxic score shall be
adjusted based on environmental fate, pursuant to subsections (e), (f) and (g).
e)Â Â Â Â Â Â Â Â The environmental fate score (F) is calculated as follows:
F = SUM(Ci * Li)
where:
1)Â Â Â Â Â Â Â Â SUM means the sum of the results of the calculation in
parentheses for each component of the wastestream;
2)Â Â Â Â Â Â Â Â Ci is the concentration of component i as a percent of the
waste by weight; and
3)Â Â Â Â Â Â Â Â Li is the environmental level of component i, as determined by
subsection (j).
f)Â Â Â Â Â Â Â Â adjusted toxic score as follows:
1)Â Â Â Â Â Â Â Â If the environmental fate score (F) is less than 100, subtract
1 from the toxic score;
2)Â Â Â Â Â Â Â Â If the environmental fate score is greater than or equal to
100 and less than 200, the toxic score is not modified;
3)Â Â Â Â Â Â Â Â If the environmental fate score is greater than or equal to
200, add 1 to the toxic score.
g)Â Â Â Â Â Â Â Â Use the toxic score or adjusted toxic score calculated
pursuant to subsections (b) through (f) for the purposes of Section 808.245.
h)Â Â Â Â Â Â Â Â Sources of toxicity data.
1)Â Â Â Â Â Â Â Â The generator is required to provide information to
substantiate that any waste is other than a type A waste.
2)        Carcinogens and mutagens. If available, use a TD50 oral rat
to represent toxicity based on carcinogenicity and mutagenicity. Otherwise:
A)Â Â Â Â Â Â Â Carcinogens are assigned a Ti of 0.1 mg/kg; and
B)Â Â Â Â Â Â Â Mutagens are assigned a Ti of 0.6 mg/kg.
3)Â Â Â Â Â Â Â Â Toxicity values shall be selected according to the following
criteria:
A)Â Â Â Â Â Â Â Toxicities are converted to equivalent oral toxicities as
specified in subsection (i);
B)Â Â Â Â Â Â Â Toxicity values are ranked by source according to the following
priorities, with the sources listed in descending order of priority.
i)Â Â Â Â Â Â Â Â Â First oral rat; then inhalation rat; then dermal rabbit; then
aquatic toxicity.
ii)Â Â Â Â Â Â Â Â If data from the bases is unavailable, then other mammalian
toxicity values;
C)Â Â Â Â Â Â Â If there is more than one toxicity value for the toxicity from
the highest priority available source, the lowest (most toxic) equivalent oral
toxicity value is used.
i)         Conversion factors for equivalent oral toxicities. The
following conversion factors must be used to convert toxicity values to
equivalent oral toxicities (Bi) (If a carcinogen or mutagen is assigned a value
for Ti in the absence of a TD
50
, Bi is assigned a value of 1.):
Toxicity measure
Units
Bi
Oral – LD
50
mg/kg
1.
Carcinogen/mutagen – TD
50
mg/kg
1.
Aquatic – 48 or 96 hour LC
50
ppm
5.
Inhalation – LC
50
mg/1
25.
Dermal – LD
50
mg/kg
0.25
j)         Environmental levels. If the waste constituent is innocuous,
the environmental level (Li) is equal to 0. Otherwise, Li for a component is
the highest level for that constituent in the following table, based on
bioaccumulation, persistence and solubility. (If a value on the boundary
between ranges, the higher value of Li is used.):
Bioaccumulation
Persistence
Solubility
Li
Min.
Max.
Min.
Max.
Min.
Max.
5
_ _ _
365
_ _ _
10,000
_ _ _
3
4
5
30
365
1000
10,000
2
0
4
0
30
0
1000
1
1)Â Â Â Â Â Â Â Â "Innocuous" waste constituents are those for which
BiTi, as determined pursuant to subsection (a), is greater than 5000 mg/kg.
2)Â Â Â Â Â Â Â Â Bioaccumulation is measured as the logarithm to the base 10 of
the n-octanol/water partition coefficient for the waste constituent, as
measured pursuant to ASTM E 1147, incorporated by reference in Section 808.111.
3)Â Â Â Â Â Â Â Â Persistence is determined pursuant to subsection (k).
4)Â Â Â Â Â Â Â Â Solubility is measured as parts per million on a weight basis.
Solubility may be measured pursuant to ASTM E 1148, incorporated by reference
in Section 808.111.
k)        Persistence. If available, a value for persistence, measured,
pursuant to subsection (k)(1), must be used. Otherwise, the table of
subsection (k)(2) must be used.
1)Â Â Â Â Â Â Â Â Persistence must be measured pursuant to ASTM E 896,
incorporated by reference in Section 808.111.
2)Â Â Â Â Â Â Â Â Persistence may be estimated using the following table. (The
longest half-life indicated must be used for constituents which fit into more
than one category):
Type of
Compound or Material
Half
Life
(days)
Metal,
metal oxide or inorganic oxide
366
Inorganic
salts
366
Asbestos
366
Clay
366
Plastics or
polymers
366
Pesticides
366
Halogenated
hydrocarbons
366
Polyaromatic
hydrocarbons and biphenyls
366
Phthalate
esters
366
Paper
products
366
Fats, oils
and greases
366
Resins and
pigments
366
Aromatic
and alicyclic hydrocarbons
31
Aliphatic
hydrocarbons
More than
10 carbons
31
10 carbons
or less
1
Waste
constituents not otherwise listed
366