35 Ill. Adm. Code 811.304
Foundation and Mass Stability Analysis
Section 811
Section 811.304 Foundation
and Mass Stability Analysis
a) The material beneath the unit shall have sufficient strength
to support the weight of the unit during all phases of construction and
operation. The loads and loading rate shall not cause or contribute to the
failure of the liner leachate collection system.
b) The total settlement or swell of the foundation shall not
cause or contribute to the failure of the liner leachate collection system.
c) The solid waste disposal unit shall be designed to achieve a
safety factor against bearing capacity failure of at least: 2.0 under static
conditions and 1.5 under seismic loadings.
d) The waste disposal unit shall be designed to achieve a factor
of safety against slope failure of at least: 1.5 for static conditions and 1.3
under seismic conditions.
e) In calculating factors of safety, both long term (over
hundreds of years) and short term (over the design period of the facility)
conditions expected at the facility shall be considered.
f) The potential for earthquake or blast induced liquefaction,
and its effect on the stability and integrity of the unit shall be considered
and taken into account in the design. The potential for landslides or
earthquake induced liquefaction outside the unit shall be considered if such
events could affect the unit.