35 Ill. Adm. Code 814.602
Applicable Standards
Section 814
Section 814.602 Applicable
Standards
a) All of the requirements for new units described in 35 Ill.
Adm. Code 817 shall apply to units regulated under this Subpart except the
following:
1) The location standards in 35 Ill. Adm. Code 817.402(a) and
(d);
2) The foundation and mass stability analysis standards in 35
Ill. Adm. Code 817.404 and 817.405;
3) The final cover requirements of 35 Ill. Adm. Code 817.410
shall not apply to units or parts of units closed, covered, and vegetated prior
to August 1, 1994;
4) The liner and leachate drainage and collection requirements of
35 Ill. Adm. Code 817.406, 817.407, and 817.408; and
5) The hydrogeological site investigation requirements of 35 Ill.
Adm. Code 817.411, except that information shall be collected to implement a
groundwater monitoring program in accordance with 35 Ill. Adm. Code 817.414 and
817.415 and establish background concentrations for the purpose of establishing
maximum allowable predicted concentrations pursuant to 35 Ill. Adm. Code
817.414.
b) Units regulated under this Subpart shall be subject to the
following standards:
1) The unit must be equipped with a system which will effectively
drain and collect leachate and transport it to a leachate management system.
However, if the facility can provide proof that the applicable groundwater
quality standards, as provided at 35 Ill. Adm. Code 817.416(a)(1), will not be
exceeded at the compliance boundary, no leachate collection or transport system
shall be required. At a minimum, such proof shall include a groundwater impact
assessment performed in accordance with 35 Ill. Adm. Code 817.413;
2) The operator shall provide a long-term static safety factor of
at least 1.5 to protect a completed unit against slope failure;
3) Calculation of the Design Period. For the purpose of calculating
financial assurance, the design period shall be calculated as follows:
A) The design period shall be no less than the operating life of
the landfill plus 15 years of postclosure care;
B) The postclosure care period shall be extended by three years
for each year the unit is expected to be in operation up to the applicable
design period required by 35 Ill. Adm. Code 817. (For example, an existing
unit with an expected operating life of three or seven years after September
18, 1990 would be required to provide financial assurance during operation and
for a postclosure care period of either 15 years since 3 x 3 = 9 years is less
than the 15 year minimum specified in subsection (b)(3)(A); or 20 years since 3
x 7 = 21 years is greater than the 20 years specified in Section 817.403(a),
respectively.)