35 Ill. Adm. Code 817.412
Plugging and Sealing of Drill Holes
Section 817
Section 817.412Â Plugging and
Sealing of Drill Holes
All drill holes, including
exploration borings that are not converted into monitoring wells, monitoring
wells that are no longer necessary to the operation of the site, and other
holes that may cause or facilitate contamination of groundwater shall be sealed
in accordance with the following standards:
a)Â Â Â Â Â Â Â Â If not sealed or plugged immediately, the drill hole shall be
covered to prevent injury to people or animals.
b)Â Â Â Â Â Â Â Â All drill holes no longer intended for use shall be
back-filled with materials that are compatible with the geochemistry of the
site and with the leachate in sufficient quantities and in such a way as to
prevent the creation of a pathway for contaminants to migrate.
c)Â Â Â Â Â Â Â Â For drill holes in gravels and other permeable strata where a
watertight seal is not necessary to prevent the creation of pathway, drill
cuttings and other earthen materials may be utilized as backfill.
d)Â Â Â Â Â Â Â Â All excess drilling mud, oil, drill cuttings, and any other
contaminated materials uncovered during or created by drilling shall be
disposed of in accordance with the requirements of 35 Ill. Adm. Code 700
through 749, 807, and 809 through 815.
e)Â Â Â Â Â Â Â Â The operator shall restore the area around the drill hole to
its original condition.